SL-863 MHL AVLink/CBUS Analyzer 3.0
.
User Guide
Simplay-UG-1006-A
July 2014

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SL-863 and is the answer not in the manual?

Questions and answers

Summary of Contents for Simplay Labs SL-863

  • Page 1 SL-863 MHL AVLink/CBUS Analyzer 3.0 User Guide Simplay-UG-1006-A July 2014...
  • Page 2: Table Of Contents

    Figure 1.1. SL-863 MHL 3 AVLink/CBUS Analyzer Hardware ....................3 Figure 1.2. SL-863 Analyzer 3.0 Installed in UTS-800 Chassis ....................4 Figure 1.3. Schematic Presentation of SL-863 MHL Rx/Tx CBUS Analyzer 3.0 Front Panel ..........5 Figure 2.1. Device Manager ..............................6 Figure 2.2.
  • Page 3: Introduction

    Simplay Labs MHL 3.0 AVLink/CBUS Analyzer 3.0, SL-863, is designed for MHL Source/Sink/Dongle DUT audio/video/eCBUS testing. The SL-863 analyzer 3.0 is used in conjunction with Simplay Labs Universal Test System (UTS) testing platform. The SL-863 analyzer 3.0 can provide the following MHL testing capabilities: 1.
  • Page 4: Figure 1.2. Sl-863 Analyzer 3.0 Installed In Uts-800 Chassis

    SL-863 MHL AVLink/CBUS Analyzer 3.0 User Guide MHL 3 Analyzer SL-863 Figure 1.2. SL-863 Analyzer 3.0 Installed in UTS-800 Chassis © 2014 Simplay Labs, LLC. All rights reserved Simplay-UG-1006-A CONFIDENTIAL...
  • Page 5: Hardware Interfaces

    Port Name Function MHL IN Connect to MHL 3 Source DUT. Connect to SL-863 PB fixture board, then SL-863 PB fixture board is connected to MHL 3 MHL OUT Sink/Dongle DUT. Connect to an external display with HDMI Port. ...
  • Page 6: Installation

    The SL-863 software, including its drivers and RTL update (if applicable), can be downloaded from Simplay Labs website (http://www.simplaylabs.com/support/product_support.aspx). 2.2. System Requirements The application for SL-863 can only be operated on a Simplay Labs UTS-800 test platform, running Microsoft Windows 7 64-bit operating system. 2.3. Driver Installation Follow these steps to install the driver on UTS-800.
  • Page 7: Figure 2.2. Popup Menu For Driver Update

    Figure 2.3. Driver Upgrade Dialog (1) 4. From the following dialog (Figure 2.4), click the “Browse…” button. Select the folder which contains the driver. Click the “Next” button to continue. Simplay-UG-1006-A © 2014 Simplay Labs, LLC. All rights reserved. CONFIDENTIAL...
  • Page 8: Figure 2.4. Driver Upgrade Dialog (2)

    5. Select “Install the driver software anyway” from the pop-up window (Figure 2.5). Figure 2.5. Windows Security Dialog 6. After the driver is installed, you can see the following dialog (Figure 2.6). © 2014 Simplay Labs, LLC. All rights reserved Simplay-UG-1006-A CONFIDENTIAL...
  • Page 9: Figure 2.6. Driver Installed Successfully

    Figure 2.6. Driver Installed Successfully 7. At the same time, you can find the installed driver from the Device Manager (Figure 2.7). Figure 2.7. The Installed Driver in the Device List Simplay-UG-1006-A © 2014 Simplay Labs, LLC. All rights reserved. CONFIDENTIAL...
  • Page 10: Microsoft .Net Framework Installation

    User Guide 2.4. Microsoft .NET Framework Installation The software for the SL-863 analyzer requires Microsoft .NET Framework and Visual C++ 2010 Redistributable Package in order to work properly. Before installing the software, go to Microsoft website and obtain both installers. Following are the links from Microsoft: ...
  • Page 11: Sl-863 Mhl Rx/Tx Cbus Analyzer 3.0 Application

    3. SL-863 MHL Rx/Tx CBUS Analyzer 3.0 Application The software application for SL-863 covers all test listed in MHL 3 CTS. With this application, you can load MHL 3 CDF files, select test, and run the test in sequence. Brief test results are shown in the Graphic User Interface (GUI) Main Window.
  • Page 12: Loading Customer Declaration Form (Cdf)

    (Figure 3.4). Select desired tests. Press the “Run” button to run a series of test. The Options menu gives you additional control while running test. See Figure 3.3 Table 3.1. © 2014 Simplay Labs, LLC. All rights reserved Simplay-UG-1006-A CONFIDENTIAL...
  • Page 13: Figure 3.3. Options Menu

    The default number is 1. All the selected test cases will run once. You can adjust the number by using the up and down arrows beside the number. All the selected cases will run multiple times upon the number you set. Simplay-UG-1006-A © 2014 Simplay Labs, LLC. All rights reserved. CONFIDENTIAL...
  • Page 14: Test Result

    For a single test case, test log may have “L1.log”, “L2.log” and “L5.log”, showing different logging levels. “L5” shows the most detailed logging information. If you want to see logging information in brief, try viewing “L1” log. © 2014 Simplay Labs, LLC. All rights reserved Simplay-UG-1006-A...
  • Page 15: Figure 3.5. Log File Folder

    SL-863 MHL AVLink/CBUS Analyzer 3.0 User Guide Figure 3.5. Log File Folder Simplay-UG-1006-A © 2014 Simplay Labs, LLC. All rights reserved. CONFIDENTIAL...
  • Page 16: Test Connection And Setup

    When testing eCBUS start-up state machine test (MHL 3 CTS Test ID 6.4.7.1), a test fixture SL863PB1 is needed for this test case. The fixture needs to be connected between the DUT and the MHL IN port of the SL-863 analyzer.
  • Page 17: Sink Dut Test Connection

    In MHL Sink DUT test, as shown in Figure 4.2, DUT needs to be connected to the MHL OUT port of the SL-863 analyzer through an MHL 3 cable. A display needs to be connected to the Monitor port through an HDMI cable.
  • Page 18: Dongle Dut Test Connection

    4.3, the MHL male connector of DUT should be connected to the MHL OUT port of the SL-863 analyzer. The HDMI port of DUT should be connected to a display through an HDMI cable. Another display should be connected to the Monitor port through an HDMI cable.
  • Page 19: Support

    In case of problems or questions, check the information from www.simplaylabs.com (Manufacturers – Product Support). You can find software updates, known issues, and other information there. If you need direct support, contact tools@simplaylabs.com. Simplay-UG-1006-A © 2014 Simplay Labs, LLC. All rights reserved. CONFIDENTIAL...
  • Page 20: References

    Abbreviation Standards Publication, Organization, and Date Mobile High-definition Link Specification, Version 3, MHL, LLC, August 2013 MHL CTS Main required methods, Version 3.0 CTS MOI Simplay MOI for CTS 3.2 © 2014 Simplay Labs, LLC. All rights reserved Simplay-UG-1006-A CONFIDENTIAL...
  • Page 21: Revision History

    SL-863 MHL AVLink/CBUS Analyzer 3.0 User Guide Revision History Revision A, July 2014 First product release. Simplay-UG-1006-A © 2014 Simplay Labs, LLC. All rights reserved. CONFIDENTIAL...
  • Page 22 General Warranty Terms Simplay Labs, LLC., (Simplay Labs), offers a limited warranty for its Simplay Labs products. Any product first sold to your business is guaranteed to be free from defects in both components and workmanship under regular uses. The warranty period commences on the date the item ships.
  • Page 23 Limitation of Liability Simplay Labs reserves the rights to refuse warranty service of products under disputable conditions. Simplay Labs also holds the rights to declare final decision whether products are within warranty conditions. The following actions and damages will result in voiding the limited warranty: Damage caused by act of nature, such as fire, flood, wind, earthquake, lightning, etc.
  • Page 24 1140 E. Arques Avenue Sunnyvale, CA 94085 T 408.616.4000 F 408.616.6398 www.siliconimage.com...

Table of Contents