RAC16 User Guide RAC16 Programmer User Guide 9M02-9029-A001-EN 9M02-9029-A001-EN Rev. 4...
Page 2
RAC16 User Guide Revision History VERSION DATE NOTES 5/2/2019 Updated Branding and expanded Configuration programming 7/19/2019 Clarified OCU timeout and added PW 9M02-9029-A001-EN Rev. 4...
Page 3
RAC16 User Guide Description The RAC16A Programmer (Figure 1), incorporates an LCD display and membrane keypad plus an electrical cable to connect to the OCU or MCU that is being programmed, it can be used to read or change the ID Code, (frequency and address) and change the OCU time-out.
Page 4
RAC16 User Guide 2. RAC16A M IGURE ENU AND UNCTIONS NOTE: Only MCU options will be available when the programmer is connected to an MCU. Likewise, only OCU options will be available when the programmer is connected to an OCU.
HREE AND SIX OSITION ONNECTORS Locate the programming connector on the OCU or MCU and connect the plug from the programmer, the plug is polarized and must be aligned as shown above. 4. RAC16 5. RAC16 IGURE CONNECTED TO IGURE...
Each system in a plant must have a separate ID Code. Rules for Assigning ID Codes • It is important to control the assignment of the unit ID Codes, Cattron accepts no responsibility for any consequences that result of failure to do so.
Page 7
RAC16 User Guide Programming If the programmer is not already switched on, apply power on by pressing the ON button. The display will show what device the programmer is connected to (OCU or MCU) for 5-seconds and then will read and display the ID Code of the unit.
Page 8
RAC16A as explained above. The ID Code will appear in the display. Copying the Configuration from one Unit to Another Connect a RAC16 to the unit containing the desired configuration and step through to READ CONFIG, enter password when prompted ‘916’.
Page 9
RAC16 User Guide OCU Time-Out The OCU ‘time-out’ is a battery-saving feature that turns off the OCU after a predetermined time of inactivity. This time is adjustable from 0 to 60 minutes, with 0 being no time-out. NB: The selection of maintained transmission or momentary transmission operation is defined within the Configuration parameters above.
Page 11
Safe-E-Stop™ is manufactured at the following location: Cattron North America Inc., 655 N River Rd NW, Suite A, Warren, OH 44483 Cattron property and confidential Due to continuous product improvement, the information provided in this document is subject to change without notice.