  • Page 1 LEVITAZ Hydrofoils Manual...
  • Page 2 Barcode labels For the mast: For the frontwing: For the rearwing: For the fuselage: 2 / 20...
  • Page 3: Table Of Contents

    Maintenance ....................... 17 Repair information ...................... 17 DISPOSING OF USED PARTS .................. 17 ORDERING REPLACEMENT PARTS ................ 18 CONTACT INFORMATION ....................18 WARRANTY POLICY ......................19 Creation: 26.06.2019 / D. Breckner 3 / 20 Release: 04.07.2019 / C. Geislinger Confidentiality code: GREEN...
  • Page 4: Introduction

    Levitaz, a brand of Geislinger GmbH or any of its agents shall not be liable for any loss, cost, claim, damage, demand or expense you may suffer whatsoever arising as a result of your actions when using the product.
  • Page 5: Warning & Safety Precautions

    WARNING & SAFETY PRECAUTIONS GDM001167-ENG-E 2 WARNING & SAFETY PRECAUTIONS WARNING! Hydrofoiling in any kind of water sports is inherently a dangerous activity that can result in serious injury or death to the user or people in the proximity of the user, with or without a Levitaz product.
  • Page 6 Before riding ensure that the bolts are tightened with the tightening torque that is • described in this manual. Geislinger GmbH is not responsible for injuries, death or damage to the product • due to misuse or any use not consistent with these instructions.
  • Page 7: Application Of The Product And Technical Data

    Material: carbon; steel; aluminum The Levitaz hydrofoil can be used with any board that has 4 metric bolt threads or any track system fitting to Levitaz plate interface dimensions. The mast interface to the board has 4 through or slotted holes (suitable for max. M8 bolts). The mounting surface of the mast is 90 mm wide and 165 mm long.
  • Page 8: Connection To The Board

    APPLICATION OF THE PRODUCT AND TECHNICAL DATA GDM001167-ENG-E 3.1 Connection to the board ➢ Check that the board and the hydrofoil are lying flat together. See figure 3.3. ➢ The bolt contact surface (between bolt and mast) must be at least 16 mm in diameter.
  • Page 9: Hydrofoil Description

    HYDROFOIL DESCRIPTION GDM001167-ENG-E 4 HYDROFOIL DESCRIPTION The standard foil consists of 7 parts: The mast (1), the front wing (2), the rear wing (3), the fuselage (4), the plate (5) and the screws (6+7). (Exception: Hydrofoils with front wings bigger than 1000 cm² have an integrated plate, which means that they consist of 6 parts).
  • Page 10: Hydrofoil Installation Instructions

    HYDROFOIL INSTALLATION INSTRUCTIONS GDM001167-ENG-E 5 HYDROFOIL INSTALLATION INSTRUCTIONS 1. Place the fuselage with the recess facing upwards. Place angle shim in correct direction (* if recommended for your model). Put the rear wing onto the (angle shim and) recess of the fuselage. Tighten both screws M6x14 to 9 ±1 Nm *Optional angle shim tightening torque with the Levitaz...
  • Page 11 HYDROFOIL INSTALLATION INSTRUCTIONS GDM001167-ENG-E 4. Hold the fuselage with one hand and attach the front wing to it with the other hand. Push it together and align the fuselage and the front wing screw holes. For front wings with integrated plate make sure the wing is in the correct angle to fit the mast.
  • Page 12 Levitaz. See chapter 3.1 “Connection to the board”. Figure 5.6 The components of the Levitaz hydrofoil can have sharp edges. For users and any other personnel involved there is a danger of injury while the components are being assembled and while the WARNING! Levitaz hydrofoil is in use.
  • Page 13: Disassembly Of The Hydrofoil

    DISASSEMBLY OF THE HYDROFOIL GDM001167-ENG-E 6 DISASSEMBLY OF THE HYDROFOIL 1. Depending on the mast model (through or slotted holes) remove or loosen the bolts from hydrofoil board connection. Figure 6.1 2. Remove all four screws M6x20 and the plate (** if supplied with your model) ** Plate only if supplied with the Levitaz mounting tool.
  • Page 14 DISASSEMBLY OF THE HYDROFOIL GDM001167-ENG-E 3. Pull out the front wing. Figure 6.3 4. Pull out the fuselage. Figure 6.4 Manufacturer: LEVITAZ 14 / 20 Contact: office@levitaz.com Confidentiality code: GREEN...
  • Page 15 *Optional angle shim Figure 6.6 The components of the Levitaz hydrofoil can have sharp edges. For users and any other personnel involved there is a danger of injury while the components are being assembled and while the WARNING! Levitaz hydrofoil is in use.
  • Page 16: Packaging And Storage

    7 PACKAGING AND STORAGE All parts are packed in a cardboard box. Every hydrofoil set comes with a suitable cover set and durable carrier bag, specially designed to hold the valuable Levitaz hydrofoil. ➢ Take the parts out of the box.
  • Page 17: Maintenance And Repair Information

    MAINTENANCE AND REPAIR INFORMATION GDM001167-ENG-E 8 MAINTENANCE AND REPAIR INFORMATION 8.1 Maintenance Clean all hydrofoil parts with fresh water after every use and dry the parts. Disassemble and rinse with fresh water after every use. Always store the disassembled product in its covers and the durable carrier bag for optimal protection.
  • Page 18: Ordering Replacement Parts

    Stick the parts’ bar code label on the first page of this manual. This will help to speed up your order for replacement parts or any possible troubleshooting. CONTACT INFORMATION LEVITAZ Hydrofoils a brand of Geislinger GmbH Hallwanger Landesstr. 3 5300 Hallwang/Salzburg AUSTRIA T: +43 662 66 999-0 E: office@levitaz.com...
  • Page 19: Warranty Policy

    WARRANTY POLICY GDM001167-ENG-E WARRANTY POLICY Levitaz warrants this product to be free from major defects — in material or workmanship — to the consumer, as defined by the Consumer Protection Act for a period of 24 month within the EU and six months outside the EU. If the customer is a company, it must inspect the goods provided immediately for non-conformances in quality and defects and must notify us in writing within two weeks from receipt of the goods;...