Zander Aachen MVisio HMI Lite Operating Manual

Master / slave mode with integrated plc-functionality

Advertisement

Quick Links

MVisio Industrial
HMI Lite
Operating Manual
MVisio HMI Lite in Master / Slave mode
with integrated PLC-functionality
English translation
Errors and technical changes reserved

Advertisement

Table of Contents
loading

Summary of Contents for Zander Aachen MVisio HMI Lite

  • Page 1 MVisio Industrial HMI Lite Operating Manual English translation Errors and technical changes reserved MVisio HMI Lite in Master / Slave mode with integrated PLC-functionality...
  • Page 2 Operating Manual MVisio Industrial HMI Lite H. Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Germany info@zander-aachen.de www.zander-aachen.de Item no.: E61-368-00 Version: L05, Ver. 1.0 This document is the English translation. Technical changes reserved, all information is subject to change. H.
  • Page 3: Table Of Contents

    Operating Manual MVisio Industrial HMI Lite 1. About this document ....................4 1.1 Validity ........................4 1.2 Target group ......................4 1.3 Legend ......................... 4 2. General safety instructions ..................5 3. About this device ....................6 3.1 Scope of delivery ....................6 3.2 Intended use ......................
  • Page 4: About This Document

    Operating Manual MVisio Industrial HMI Lite About this document Validity This document is valid for the MVisio HMI Lite (Human Machine Interface) of ZANDER- Aachen (art.-no. 589 101). Target group Electricians, installation-, commissioning- and service personnel with appropriate knowledge in handling automation technology components.
  • Page 5: General Safety Instructions

    Operating Manual MVisio Industrial HMI Lite General safety instructions Only authorized and qualified personnel may install the device and put it  into operation, i.e. personnel which is well-acquainted with correct technical handling of the electrical Warning, machine equipment, Caution is familiar with the applicable regulations concerning occupational safety and accident prevention, has read and understood the operating manual and, if applicable,...
  • Page 6: About This Device

     Intended use The MVisio HMI Lite was designed for the use in machinery and equipment in industrial environments. The front of the device has a minimum type of protection of IP66. The per- missible operating parameters must be observed for the use (see paragraph 4).
  • Page 7: Technical Data

    Operating Manual MVisio Industrial HMI Lite Technical data Specifications Display Touchscreen technology Resistive Display / Backlight TFT Colour / LED Colours 64 000 Brightness 200 Cd / m typ. Resolution 800 x 480 Diagonal 7” Format 16:9 Dimming Type of protection IP 66 (front), IP 20 (back) Controller Operating system...
  • Page 8 Operating Manual MVisio Industrial HMI Lite Supported bus systems Ethernet / protocols PROFINET (Controller/Master) EtherNET/IP (Scanner/Master) Modbus TCP (Master/Slave) Field bus Modbus RTU (Master/Slave) CANopen (Master) Serial 2x RS232, 2x RS422/RS485, 2x CAN PLC data Programming CODESYS V3 Approved for CODESYS version V 3.5.12.10 Programming languages IEC 61131-3 (AWL, KOP, FUP, AS, ST)
  • Page 9: Environmental Data

    Although the resistance level of the device meets the standards, oils that are expected to have no influence on the MVisio HMI Lite, may damage the device. This might happen in places with vaporous oils or when cutting oils with low viscosity adhere on the device for a longer period of time.
  • Page 10: Durability Information

    Operating Manual MVisio Industrial HMI Lite Immunity to burst ± 2 kV DC power connection EN 61000-4-4 ± 1kV signal line Immunity to surge ± 0,5 kV DC mains connection (line to ground) EN 61000-4-5 ± 0,5 kV DC mains connection (conductor to conductor) ±...
  • Page 11: Dimensions

    Operating Manual MVisio Industrial HMI Lite Dimensions Figure 1: Dimensions of the MVisio HMI Lite Assembly Figure 2: Assembly of the MVisio HMI H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany • Tel +49 241 9105010...
  • Page 12 Operating Manual MVisio Industrial HMI Lite The assembly of the MVisio HMI Lite is shown in figure 2. Avoid permanent exposure to direct sunlight to prevent the device from overheating. The MVisio HMI Lite is not designed for the installation with corrosive chemical com- pounds.
  • Page 13: Electrical Connections And Dip-Switch Configuration

    Operating Manual MVisio Industrial HMI Lite Electrical connections and DIP-switch configuration Figure 4: terminal block designation Connection Slot Function Power supply RS422/485 + CAN (COM2/CAN0) RS422/485 + CAN (COM3/CAN1) RS232 + RS232 (COM/COm4) USB-Port USB-Port Ethernet-Port 0 (10/100/1000 Mbit) Ethernet-Port 1 (10/100 Mbit) RS485 + CAN-Port-configuration (DIP-switch) RS485 + CAN-Port-configuration (DIP-switch) H.
  • Page 14: Serial Interfaces / Can Interfaces

    Operating Manual MVisio Industrial HMI Lite Switch Switch CAN-A CAN-B Termination Termination RS422/485-A RS422/485-B Mode Mode RS422/485-A RS422/485-B Termination Termination Serial interfaces / CAN interfaces 6.1.1 RS232 (X4) RS232 COM 1 COM 4 Figure 5: Terminal block designation X4 6.1.2 RS485 / CAN (X2 and X3) Figure 6: Terminal block designation X2 and X3 H.
  • Page 15 Operating Manual MVisio Industrial HMI Lite RS485 Connection n.c. GND1 CAN 0 Terminating resistor CAN-H CAN-L Terminating resistor Terminating resistor n.c. COM 2 Terminating resistor Y (TX+) Z (TX-) A (RX+) B (RIX+) n.c. CAN 1 Terminating resistor CAN-H CAN-L Terminating resistor Terminating resistor n.c.
  • Page 16: Rs485 (Can-Port Configuration - Dip-Switch S1 And S2)

    Operating Manual MVisio Industrial HMI Lite 6.1.3 RS485 (CAN-Port configuration - DIP-switch S1 and S2) Position Description CAN-terminating resistor CAN-terminating resistor RS485-half-duplex RS485-half-duplex RS485-terminating resistor RS485-terminating resistor Ethernet ports The Ethernet ports have two status LEDs, see figure 7. Green Yellow Figure 7: Ethernet port Green...
  • Page 17: Connecting The Power Supply

    Operating Manual MVisio Industrial HMI Lite 7. Connecting the power supply The pluggable terminal block for the power supply including the terminal designation is shown in figure 8. Make sure the power supply offers enough power capacity for the oper- ating device.
  • Page 18: Battery

    Operating Manual MVisio Industrial HMI Lite Figure 9: Connection the power supply Battery The HMI Lite is equipped with a rechargeable lithium battery (see figure 10), which sup- plies the real-time clock and can not be replaced by the customer. The battery must be charged for 48 hours at the first installation.
  • Page 19: Additional Application Notes

    10.2 System settings The MVisio HMI Lite has a menu in which the system settings can be configured. The user interface of the system settings is based on HTML-pages which are accessible via the HMI Lite screen or via the web browser Chrome (V.44 or higher) using port 443 (see figure 11).
  • Page 20 Operating Manual MVisio Industrial HMI Lite Figure 11: System settings in a browser Another way of getting into the system settings is by starting the HMI Lite in „Tap-Tap- Mode“. To do this, you have to press the screen of the HMI with a frequency of 2 Hz or higher (at least 2 times per second) when starting the device.
  • Page 21: Boxing And Unboxing

    When boxing the device again, please follow the instruction in reverse order. Figure 12: Unboxing the MVisio HMI Lite H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany • Tel +49 241 9105010...
  • Page 22: Declaration Of Conformity

    Operating Manual MVisio Industrial HMI Lite Declaration of Conformity H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany • Tel +49 241 9105010 Fax +49 241 91050138 • info@zander-aachen.de • www.zander-aachen.de...
  • Page 23: Notes

    Operating Manual MVisio Industrial HMI Lite Notes H. ZANDER GmbH & Co. KG • Am Gut Wolf 15 • 52070 Aachen • Germany • Tel +49 241 9105010 Fax +49 241 91050138 • info@zander-aachen.de • www.zander-aachen.de...

Table of Contents