SAFETY NOTICE
PlEASE rEAD THIS ENTIrE MANuAl BEFOrE YOu INSTAll AND uSE YOur NEw FIrEPlACE. FAIlurE TO
FOllOw INSTruCTIONS MAY rESulT IN PrOPErTY DAMAgE, BODIlY INjurY, Or EVEN DEATH.
FOr uSE IN THE u.S. AND CANADA. SuITABlE FOr INSTAllATION IN MOBIlE HOMES
IF THIS HArMAN BuIlT FIrEPlACE IS NOT PrOPErlY INSTAllED, A HOuSE FIrE MAY rESulT. FOr YOur
SAFETY, FOllOw INSTAllATION DIrECTIONS.
CONTACT lOCAl BuIlDINg Or FIrE OFFICIAlS ABOuT rESTrICTIONS AND INSTAllATION INSPECTION
rEQuIrEMENTS IN YOur ArEA.
CONTACT YOur lOCAl AuTHOrITY (SuCH AS MuNICIPAl BuIlDINg DEPArTMENT, FIrE DEPArTMENT, FIrE
PrEVENTION BurEAu, ETC.) TO DETErMINE THE NEED FOr A PErMIT.
CETTE guIDE D'uTIlISATION EST DISPONIBlE EN FrANCAIS. CHEz VOTrE CONCESSIONNAIrE DE HArMAN
STOVE COMPANY.
R1
SAVE THESE INSTruCTIONS.

Advertisement

Table of Contents
loading

Summary of Contents for Harman Built Serenity II HB35 DV

  • Page 1 FOllOw INSTruCTIONS MAY rESulT IN PrOPErTY DAMAgE, BODIlY INjurY, Or EVEN DEATH. FOr uSE IN THE u.S. AND CANADA. SuITABlE FOr INSTAllATION IN MOBIlE HOMES IF THIS HArMAN BuIlT FIrEPlACE IS NOT PrOPErlY INSTAllED, A HOuSE FIrE MAY rESulT. FOr YOur SAFETY, FOllOw INSTAllATION DIrECTIONS.
  • Page 2 WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
  • Page 3: Table Of Contents

    Table of Contents Introduction Safety Precautions Operation Specifications Installation Arch Face Venting Fuel Conversion Log Placement Option Installation Thermostat Remote Control Maintenance Wiring Diagram Parts Trouble Shooting Warranty...
  • Page 4: Introduction

    Introduction The Harman Serenity II Direct Vent Gas Fireplace is When operating your Harman Serenity II Gas Fireplace, a listed gas-fired direct vent room fireplace tested by respect basic safety standards. Read these instructions Intertek Testing Services/Warnock Hersey to ANSI carefully before you attempt to operate the fireplace.
  • Page 5: Operation

    OPERATION Operation A lABEl ON THE BurNEr SYSTEM MODulE STATES THE FuEl FOr HOW TO LIGHT THE FIRE wHICH THE HEATEr IS EQuIPPED. High-Low 1. STOP! Read the safety information on page 2. Gas Control 2. If using the optional thermostat, set thermostat to the lowest setting.
  • Page 6 OPERATION 15. Set the High-Low Regulator to desired setting: Turn fully counterclockwise for High and fully clockwise Bottom rear view of burner module. for Low. NOTE: An odor, resulting from the initial heating of new materials in your heater, is not unusual during the first fire, and in most cases will disappear after an hour or two.
  • Page 7: Specifications

    SPECIFICATIONS Top Standoffs Accordion Heat Vent Collar Exchanger Brick Door Latches Glass Door Lift Handles Electrical Box Blower Speed Switch On-Off- Thermostat Switch Ignitor Hi-Low Knob Burner Module On-Off-Pilot Knob rATINgS NATurAl PrOPANE Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m) 31000 31000 Min. Input Rating (Btu/hr)(0-4500 ft.)(0-1375 m) 21000 21000 Orifices (DMS)(0-4500 ft.)(0-1375 m) 36...
  • Page 8 SPECIFICATIONS Electrical Rating: 120 Volts, 60 Hs, >2.75 AMP MINIMUM CLEARANCES FROM COMBUSTIBLE CONSTRUCTION: Unit to floor 0 in. Face to side wall 7 in. Unit to top stand-offs 0 in. Unit to side stand-offs 0 in. Unit to rear stand-offs 0 in.
  • Page 9 SPECIFICATIONS Top View 16.374 15.374 Gas In Gas In Electric In 36.879 Left Side View Right Side View Corner Top View...
  • Page 10: Installation

    ( part # 1-00-4235231 for arch faces and 1-00- 4235240 for rectangular faces ) are available. We also offer a line of Harman Built mantels, mantel cabinets, and corner mantel cabinets. Shown is the M2 Mantel Cabinet with marble finish facing, raised marble finish hearth and a gold plated Arch face with Arch hood.
  • Page 11 INSTALLATION Only For Qualified Installers Placement This appliance must be electrically connected and grounded in accordance with local codes or in the Here are some of the things that will affect the exact absence of local codes, with the current edition of placement of the fireplace.
  • Page 12 INSTALLATION Only For Qualified Installers Installing fireplace in a wall with an arch face, ceramic tile facing, and a Harman Built (M1) Mantel. Noncombustible Noncombustible material such as Dura-rock must be used as 1 inch thick facing on the front of the fireplace cabinet.
  • Page 13 INSTALLATION Only For Qualified Installers Installing The Arch Face To install the arch face, place the hooks on the bottom rear of the face into the hook slots on the fireplace. Next, with the top latch handles in the Latch Handles horizontal position push the face against the fireplace and swing the latches straight down causing them to enter the top face slots.
  • Page 14 INSTALLATION Only For Qualified Installers Burn Only the Fuel for which the Heater is LP Gas: Equipped Maximum inlet pressure 13” w.c. (3.24 kPa) The Serenity II Direct Vent will burn either natural gas Minimum inlet pressure 11” w.c. (2.74 kPa) or propane, but requires a change over kit for propane.
  • Page 15: Venting

    VENTING Only For Qualified Installers EXCELDirect Component List 4” I.D. 5” I.D. liste des composants Component Name 6 ⅝” O.D. 8” O.D. longueurs lengths Longueur 6” Galvalume 6” Length Galvalume TC-4DL6 TC-5DL6 Longueur 6” Noire 6” Length Black TC-4DL6B TC-5DL6B Longueur 12” Galvalume 12” Length Galvalume TC-4DL1 TC-5DL1 Longueur 12” Noire 12” Length Black TC-4DL1B TC-5DL1B Longueur 24” Galvalume 24” Length Galvalume TC-4DL2...
  • Page 16 VENTING Only For Qualified Installers Selkirk Direct- Temp / Simpson Dura-Vent Direct Vent gS Cross refference of Approved Venting Components Simpson Dura-Vent Direct Vent gS Selkirk Direct-Temp Stock No. Description Stock No. Description 908 6” Pipe Length, Galvanized 4DT-6 6” Pipe Length, Galvanized 908B 6” Pipe Length, Black 4DT-6B 6” Pipe Length, Black 907 9” Pipe Length, Galvanized...
  • Page 17 VENTING Only For Qualified Installers SECurE VENT DIrECT VENT SYSTEM - 4” x 6-5/8” and 5” x 8” Cross reference list Secure Simpson Dura-Vent Secure Simpson Dura-Vent Vent Direct Vent gS Vent Direct Vent gS Description Cat No. Stock No. Cat No.
  • Page 18 VENTING Only For Qualified Installers Standard Series Direct Vent (4”/ 7”) Description Order Code HOrIzONTAl TErMINATIONS 3” length, no mounting frame (use with MSR or MOSR) MTO3 3” Termination, with integral mounting frame MTO3F VErTICAl TErMINATION Termination for vertical installations MVTK1 Includes MXT-10 adaptor (for straight, vertical installations) Termination Touch-Up Paint Paint03 VENT PIPES Extensions 18” rigid section (female/female) EXT18 12” rigid section (female/male) MEXT1 24” rigid section (female/male) MEXT2 36” rigid section (female/male) MEXT3 48” rigid section (female/male) MEXT4 72” rigid section (female/male) MEXT6 Flex Sections...
  • Page 19 VENTING Only For Qualified Installers Standard Series Direct Vent (4”/ 7”) Description Order Code SNOrkEl TErMINATIONS 18” vertical rise SNK47-2 30” vertical rise SNK47-3 HEAT guArD Fits all Standard Series (4/7”) terminations MTKOG HEAT SHIElDS Through-the-wall radiation Shield for 4”/7” venting RHS100 Vinyl Siding Shield Recommended for protecting vinyl siding RHS105 VSS) (above was Discontinued Replace with Vinyl Siding Shield Recommended for protecting vinyl siding VSS VErTICAl INSTAllATION ACCESSOrIES...
  • Page 20 VENTING Only For Qualified Installers Premium Series Direct Vent (5”/8”) Description Order Code HOrIzONTAl TErMINATIONS 3” Termination with no mounting frame (male connector) PTO3 (use with MSR or MOSR). 3” Termination & mounting frame (male connector) PTO3F VErTICAl TErMINATION Termination for vertical installations (male connector) PVTK1 Includes PXT-10 adaptor (for straight, vertical installations). VENT PIPES Note: For all Rear Vent applications with no vertical rise, there is a maximum horizontal run of 20”. Extensions 5” rigid section (female/female connectors) PXT5 10” rigid section (female/female) PXT10 20” rigid section (female/female) PXT20 12” rigid section (female/male connectors) PEXT1 24” rigid section (female/male) PEXT2 36” rigid section (female/male) PEXT3...
  • Page 21 VENTING Only For Qualified Installers Premium Series Direct Vent (5”/8”) Description Order Code SNOrkEl TErMINATIONS 18” vertical rise SNK58-2 30” vertical rise SNK58-3 INSulATED OFFSET BOx M38DV-ST offset box. Used only on the M38DV-ST when a shelf or T.V. stand is required above the fireplace DVSTCNT HEAT guArD Fits all Premium Series (5”/8” dia.) terminations PTKOG HEAT SHIElDS Through-the-wall radiation Shield for 5”/8” venting RHS101 Vinyl Siding Shield Recommended for protecting vinyl siding RHS105 Discontinued Replace with VSS Vinyl Siding Shield Recommended for protecting vinyl siding...
  • Page 22 VENTING Only For Qualified Installers HB35 This appliance must not be connected to a chimney flue Venting with 8” x 5” Pipe serving a separate solid fuel burning appliance. Maximum of four 45 elbows allowed. Subtract three feet of total horizontal pipe length for each of the 3rd and 4th 45 elbows used.
  • Page 23 INSTALLATION Only For Qualified Installers HB35 Venting with 6 ” x 4” Pipe Maximum of four 45 elbows allowed. Subtract three feet of total horizontal pipe length for the 3rd and 4th 45 elbow used. Maximum of two 90 elbows allowed. Subtract five feet of total horizontal pipe length for second elbow.
  • Page 24 INSTALLATION Only For Qualified Installers Requirements for Terminating the Venting I. The clearance to service regulator vent outlet must be WARNING: Venting terminals must not be recessed a minimum of 6 feet (1.8 m). into a wall or siding. J. The clearance to a non-mechanical air supply inlet to In addition, the following must be observed: the building or the combustion air inlet to any other A.
  • Page 25 INSTALLATION Only For Qualified Installers Damper Settings Maximum Draft Minimum Draft A vent damper is provided to allow fine tuning of the draft. Too little draft will cause flames to be too long with black tips and too much draft will cause flames to be short and blue.
  • Page 26 INSTALLATION Only For Qualified Installers Changing to LP Remove screw Remove screw Remove two screws shown above. Next remove the burner tube, grate bar assembly by lifting the front of the assembly and sliding to the right. Air Deflector Remove screw Remove screw Remove air deflector screws shown.
  • Page 27 INSTALLATION Only For Qualified Installers Read instructions packed with LP Change-over Kit. Remove two screws and place Control Panel to the left. LP Conversion Kit LP Conversion Instructions Remove three screws to change knob assembly. Install LP knob assembly in place of the NG assembly. Be sure screws are tight.
  • Page 28: Log Placement

    INSTALLATION Only For Qualified Installers Log Placement Log Pin Rear Log Side Log Front Log Top Log Place the rear log in the center and against the brick at Place the front log down over the pin shown above. the rear of the firebox. Slide the right side to the rear until it hits the rear log.
  • Page 29: Thermostat

    INSTALLATION (Options) Only For Qualified Installers Connecting the Optional Thermostat If the optional thermostat is used, it must be plugged into the terminal strip located in the lower left front corner of the heater. When installing a millivolt control system, use only a special low resistance thermostat.
  • Page 30: Maintenance

    MAINTENANCE Replacing the Gasket A qualified service person recommended by your Harman dealer should conduct an annual inspection The Serenity uses part no. 3-44-00539 fiberglass gasket in the front door. Should it ever need replacement, use and maintenance of your fireplace, its venting, and the only the proper replacement gasket that is available installation to keep it running safely and efficiently.
  • Page 31 MAINTENANCE Air Flow It is essential that air flows freely into the bottom grill and out of the top grill. Do not place objects in front of the grills. Air Out Check blower annually for buildup caused by dust and pet hair. Cleaning the Burners To clean the burners, the face, glass front, and logs must be removed.
  • Page 32 MAINTENANCE...
  • Page 34: Parts

    Serenity II (HB35) Service Parts Beginning Manufacturing Date: N/A Direct Vent gas Fireplace Ending Manufacturing Date: july 2009 1-70-09000 (Top Vent) log Set Assembly Part number list on following page. 06/12...
  • Page 35 Serenity II (HB35) Service Parts Beginning Manufacturing Date: N/A Ending Manufacturing Date: july 2009 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed at Depot in this manual may be ordered from an authorized dealer. ITEM DESCrIPTION COMMENTS PArT NuMBEr Rear log 3-40-09206 Front log 3-40-09207 Left Side log 3-40-09208 Knothole log 3-40-09209 Adapter 6-5/8” to 8” 3-40-12223 Drywall Shelf 1-00-4235181 No longer available Compression Springs 2”...
  • Page 36 Serenity II (HB35) Service Parts Beginning Manufacturing Date: N/A Ending Manufacturing Date: july 2009 #29 Burner Module Assembly 29.7 29.2 29.3 29.6 29.5 29.1 29.4 29.8 29.9 29.10 29.15 29.11 29.13 29.14 29.18 29.12 29.17 29.16 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement parts for Stocked your appliance please provide model number and serial number. All parts listed in this manual may be ordered from an authorized dealer. at Depot ITEM DESCrIPTION...
  • Page 37 Serenity II (HB35) Service Parts Beginning Manufacturing Date: N/A Ending Manufacturing Date: july 2009 IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement Stocked parts for your appliance please provide model number and serial number. All parts listed at Depot in this manual may be ordered from an authorized dealer. ITEM DESCrIPTION COMMENTS PArT NuMBEr Arch Open Face Black only 1-00-4235233-13 Arch Scroll Grill Black only 3-43-4235246-13 3-44-08714 Gasket, Silica Explosion Relief High volt harness 3-20-09213 Scroll Grill Door Black only 3-43-4235247-13 Single Burner Remote 1-00-7911 Stove adapter Hbf 8” outer 3-40-08788 Term blk harness...
  • Page 38: Trouble Shooting

    TROUBLE SHOOTING Only For Qualified Installers Natural Gas Manifold Pressure Inlet Pressure 3.5 inches 5 to 7 inches Pilot Adjuster Propane Manifold Pressure Inlet Pressure 11 10 inches to 13 inches Pilot Adjuster...
  • Page 39 TROUBLE SHOOTING Only For Qualified Installers Pilot does not light after many tries Look to see if a spark jumps Check ignitor wire and Reconnect or replace from the ignitor electrode to the connections from piezo ignitor Ignitor wire. pilot when the ignitor button is to ignitor ceramic at pilot.
  • Page 40 TROUBLE SHOOTING Only For Qualified Installers Pilot does not stay lit Check inlet pressure Correct inlet pressure Good Adjust pilot adjustment to Check size of pilot flames achieve proper flame. Good Check Milivolt output Replace Thermocouple of thermocouple. Should be 10 or more MV. Good Replace Valve...
  • Page 41 TROUBLE SHOOTING Only For Qualified Installers Main Burner will not light (with valve in “on” position) Light pilot Is Pilot lit Check Thermopile voltage a t t e r m i n a l s m a r k e d TP on valve.
  • Page 42: Warranty

    Harman Built Fireplaces. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman Built Fireplaces and its agents assume no liability for “resultant damages of any kind” arising from the use of its products. In addition, the manufacturer and its warranty administrator shall be held free and harmless from liability from damage to property related to the operation, proper or improper, of the equipment.