Fax: +49 751 56146-29 Internet: www.ixxat.com E-Mail: info@ixxat.com Support In case of unsolvable problems with this product or other IXXAT products please contact IXXAT in written form: Fax: +49 751 56146-29 E-Mail: support@ixxat.de Further international support contacts can be found on our webpage www.ixxat.com...
Introduction 1 Introduction Overview In the IXXAT Econ 100, you have purchased a high-quality electronic compo- nent that has been developed and manufactured according to the latest tech- nological state of the art. Features CPU: Xilinx Zynq XC7Z010 with dual-core Cortex A9 CPU and integrated FPGA ...
IXXAT Econ 100 is contained on the SD card provided. This must be installed in the SD card slot on the IXXAT Econ 100. Access to the SD card slot can be found on the back of the unit. Refer to chapter 3.2.8.
The function of the Ethernet interfaces and the LEDs are application specific. Their function is described in the Software Developer´s Guide. Figure 3-1: Connections and labels Figure 3-2: Connection of power pupply Copyright IXXAT Automation GmbH IXXAT Econ 100 hardware manual, version 1.3...
Connections and displays Connections 3.2.1 Power supply connection Connection of the IXXAT Econ 100 to a power supply uses a 2-pin plug with a screw connection (Phoenix Contact MC 1,5/2-STF-3,5). The pinout for the screw terminal is shown in Table 3-3.
3.2.3 LAN 2 The LAN 2 RJ45 connector provides another Ethernet connection for commu- nication with the IXXAT Econ 100. This supports 100Base-TX and 10Base-T with Auto-MDI-X. The pinout for the RJ45 connector are shown in Table 3-5. Pin no. RJ45...
ISO11898-2. Each CAN connection is galvanically isolated from both the main electronics and also from the other CAN circuit. Each connection of the IXXAT Econ 100 to the CAN bus uses a 9-pin D-SUB connector. The pinout for the plugs is shown in Table 3-8.
The SD card slot is accessible on the back of the housing. An SD card with a valid data format is essential, since the IXXAT Econ 100 is booted from the SD card. Valid file formats are FAT16 and FAT32. SD cards with up to 32 GB memory are supported.
SD card slot Figure 3-10: SD card slot on the back 3.2.9 PE connection The PE connection uses the holder for the tophat rail on the back of the hous- ing. Copyright IXXAT Automation GmbH IXXAT Econ 100 hardware manual, version 1.3...
Connections and displays Indicators The IXXAT Econ 100 has seven Duo LEDs as well as a green power LED. These LEDs are used to display the communications status of the interfaces and/or to display device status and mode. The seven Duo LEDs can be con- trolled by the software.
Additional interfaces are implemented on the circuit board that are not led out- side and are only accessible with the housing open. These can be seen in Figure 3-11. Copyright IXXAT Automation GmbH IXXAT Econ 100 hardware manual, version 1.3...
The 4-pin X1300 pin strip provides a USB 2.0 interface to connect USB devic- es. The power supply provided on the pin strip is not protected. The connec- tion pinout of the serial interface is shown inTable 3-12. Copyright IXXAT Automation GmbH IXXAT Econ 100 hardware manual, version 1.3...
The battery provides the power supply for the real-time clock when the IXXAT Econ 100 is disconnected from its main power supply. When changing the bat- tery, be sure that a CR1632 3 V lithium battery is used that is suitable for op- eration in the temperature range required.
Zynq. The supply voltage carried on the connector is the filtered input voltage used to operate the IXXAT Econ 100. The +3.3 V voltage is the +3.3 V voltage generated on the IXXAT Econ 100.
Page 18
Pin no. X800 Signal supply voltage supply voltage B34_L21N_T3_DQS B35_L20P_T3_AD6P B34_L23P_T3 B35_L20N_T3_AD6N B35_L21P_T3_DQS_AD14P B34_L23N_T3 B34_L24P_T3 B35_L21N_T3_DQS_AD14N B34_L24N_T3 B35_L22P_T3_AD7P B35_L22N_T3_AD7N +3.3 V +3.3 V B35_L24P_T3_AD15P B35_L24N_T3_AD15N Table 3-15: Pinouts for expansion port Copyright IXXAT Automation GmbH IXXAT Econ 100 hardware manual, version 1.3...
Disposing of old equipment This product is covered by ElektoG (WEEE) and has to be disposed according to ElektoG (WEEE) separately. Products of IXXAT, which are covered by Elek- toG, are exclusively for commercial use and marked with the symbol of the crossed-out garbage can.
EMC: use only the included accessories the shield of the interfaces must be connected with the device plug and with the plug on the other side Copyright IXXAT Automation GmbH IXXAT Econ 100 hardware manual, version 1.3...
EC Declaration of Conformity 5 EC Declaration of Conformity IXXAT Automation declares, that the product: IXXAT Econ 100 with the article numbers: 1.01.0271.xxxxx complies with the EU directive 2004/108/EC. Applied harmonized standards: EN 61000-6-4:2007 + A1:2011 EN 61000-6-2:2005 24.09.2013, Dipl.-Ing. Christian Schlegel, Managing Director IXXAT Automation GmbH Leibnizstr.
Need help?
Do you have a question about the Econ 100 and is the answer not in the manual?