TLE3100C02 module can operate as an SNTP time server when the mounting frame has a GPS reception module installed. The TLE3100C02 is a TL3000 terminal line module and can be housed in a three rack unit (3 RU) UR3000 mounting frame or a 1 RU UR3100 mounting frame.
Albalá Ingenieros | Manual TLE3100C02 2. SPECIFICATIONS Ethernet interface Connector RJ45 Encoding and electrical characteristics: 100BASE-T According to IEEE std 802.3u standard 10BASE-T According to IEEE std 802.3i standard Operating modes Auto-Negotiation speed, full duplex/half duplex Supported protocols IP, ARP, ICMP, TCP, UDP, SNTP, HTTP,...
Page 8
Albalá Ingenieros | Manual TLE3100C02 GPO output Connector Plug-in terminal, 3.81 mm pitch Type Relay closing contact to ground Number of outputs Allowed voltage range ±50 V 250 mA max. Power supply output Connector Plug-in terminal, 3.81 mm pitch Nominal voltage...
ELECTROSTATIC DISCHARGE. Always use antistatic bags clearly identified with a high degree of shielding for storage and transportation. The TLE3100C02 module is composed of two parts: one TLE3100P01 main board and one TLE3000P02 rear board. Both parts must be installed in a UR3000 or UR3100 mounting frame following the instructions in the corresponding section of this chapter.
3.5. Installing the module in the mounting frame The steps needed to install the TLE3100C02 module with the rear board in the mounting frame are: 1 - Disconnect all power cords from the power supplies of the mounting frame.
Page 11
5 - Affix the main board to the mounting frame using the two screws included on the front panel. 6 - Insert the TLE3100P01 board (main board of the TLE3100C02 module) into the front of the mounting frame. The edges of the card slide into two plastic guides inside the mounting frame.
Albalá Ingenieros | Manual TLE3100C02 3.6. Interconnection The following figure shows the TLE3100C02 module rear board connector layout. Rear view of the TLE3100C02 The POWER SUPPLY OUTPUT connector provides a re-settable fuse protected, unregulated +6 V output with a reference to chassis ground and capable of supplying up to 750 mA.
Page 13
Once the 48 V power supply has been activated the TLE3100C02 maintains it until an output overload (output over-current) is detected or until the TLE3100C02 detects that the external equipment has been disconnected.
Page 14
Albalá Ingenieros | Manual TLE3100C02 Connection cable between the TIA-EIA-232-F serial port of a PC and the TLE3100C02 module. Connection cable between TLE3100C02 modules and KBD3016 keyboards using a TIA-EIA-485-A bus. The general purpose inputs and output of the module are located in the connector labeled GPIO.
Albalá Ingenieros | Manual TLE3100C02 3.6.1. GPI connections The GPI inputs use 3.81 mm pitch terminal block connectors and their equivalent circuit is as follows: Before connecting these signals please consult the maximum values shown in the specifications section. Never connect dangerous potentials to GPI inputs.
Albalá Ingenieros | Manual TLE3100C02 4. OPERATION This section describes the significance of the front panel indicators of the TLE3100C02 module and their remote control and monitoring ability. 4.1. Front panel description The appearance of the front panel and the elements it contains are shown in the following illustration.
Albalá Ingenieros | Manual TLE3100C02 In the ETHERNET box: LINK: Green. This LEDs lights up when the module is connected correctly to an Ethernet LAN. FULL DUP.: Green. This LED lights up when the communication mode is full duplex. If this LED is off, the communication mode is half duplex.
Albalá Ingenieros | Manual TLE3100C02 4.3. Module remote control and supervision The main function of the communications control module is to interface between a 10/100 Ethernet port, an EIA-RS232 or an EIA-RS485 serial port and the internal bus of the mounting frame. The following illustration shows the most common control situations: from a computer or control panel via Ethernet, from a computer via an EIA-RS232 serial port and from a control panel via an EIA-RS485 serial port.
Slot 15. All commands sent to Slot 0 receive a response from the TLE3100C02 module as if they had been directed to Parameters are always values between 0 and 255 (one byte) that are coded for transmission as two bytes.
Page 21
Albalá Ingenieros | Manual TLE3100C02 The following gives an example of a possible command: Field Value ASCII Characters Transmitted Identifier 0x64h Frame address 24d (0x18h) 0x31h, 0x38h Slot number 10d (0x0A) 0x3Ah Parameter 1 131d (0x83h) 0x38h, 0x33h Parameter 2...
The TLE3100C02 module implements an SNTP protocol used to set the time for the equipment using IP networks in both client mode and server mode. When operating in client mode the time for the TLE3100C02 module can be set from an Internet time server. If the mounting frame where the TLE3100C02 module is installed includes a GPS receiver then the TLE3100C02 can operate as an Internet time server so that other equipment can set its time.
If simultaneous transfers are attempted the module will respond with an error packet indicating the status of transfer in progress and the number of the block that was being processed. The possible states of the TLE3100C02 module's TFTP state machine are as following: - 0: TFTP_IDLE.
Page 24
# identification of the sector to be erased (2 digits) # checksum of the previous bytes (## = ignore, 2 digits) The TLE3100C02 can also use the following configuration file types: Any files that begin with tle3100c for loading the module's EEPROM. These are 64 byte binary files in which the last two bytes are the 1's complement of the arithmetic sum of the first 62 bytes stored in little-endian format.
Albalá Ingenieros | Manual TLE3100C02 4.3.5. Details of the TLE3100C02 registers The TLE3100C02 module includes control and status registers for remote configuration and supervision. These registers can be written and read using the commands previously described. The parameter information grouped in the CONTROL or RAM sections is stored in volatile memory.
Page 26
Albalá Ingenieros | Manual TLE3100C02 GPS_BRD_ADD 0x00 0x2C 0x0F GPS module slot STATUS Name snmp trap Description GPI1 0x01 0x01 GPI1 status 0=Inactive, 1=Active GPI2 0x01 0x02 GPI2 status 0=Inactive, 1=Active GPI3 0x01 0x04 GPI3 status 0=Inactive, 1=Active GPI4 0x01...
Page 27
Albalá Ingenieros | Manual TLE3100C02 EV4_MIN 0x00 0x0B 0x3F Event 4: minute = x m EV1_GPO 0x00 0x0C 0x0F Event 1: GPOs status EV2_GPO 0x00 0x0D 0x0F Event 1: GPOs status EV3_GPO 0x00 0x0E 0x0F Event 1: GPOs status EV4_GPO...
Albalá Ingenieros | Manual TLE3100C02 5. GLOSSARY Global Positioning System. A telecommunication system formed by an array of satellites that transmit information to the earth's surface. Timing and position can be determined by using GPS along with an appropriate receptor.