EN: Installation Sheet
Description
The Genesis WG4 Outdoor Horn-Strobe is a life safety
notification appliance designed for indoor or outdoor use on
ceilings or on walls. See Table 1 for a list of models and
Table 2 for a list of accessories.
For surface mount applications, mount the WG4 onto a Model
449 electrical box using the gasket shipped with the appliance.
For flush mount applications where the mounting surface is
flush with the surface of the wall or ceiling, use the WG4GSKT
gasket kit.
Note that you need a Model 449 electrical box for waterproof
applications, or a standard mount 4in. square box for all other
applications.
The horn-strobe includes field-configurable jumper options that
allow you to set the strobe pattern to temporal or continuous,
the horn pattern to temporal or continuous, and the horn
volume to low or high. The horn-strobe also includes a field-
configurable switch for setting the strobe candela level. This
setting is locked in place and is visible after final installation.
Table 1: Models
Number
Description
WG4WF-HVMC
Outdoor rated wall/ceiling horn-strobe, white with
FIRE marking, clear lens
© 2012 UTC Fire & Security. All rights reserved.
Number
Description
WG4WN-HVMC
Outdoor rated wall/ceiling horn-strobe, white
without marking, clear lens
WG4RF-HVMC
Outdoor rated wall/ceiling horn-strobe, red with
FIRE marking, clear lens
WG4RN-HVMC
Outdoor rated wall/ceiling horn-strobe, red without
marking, clear lens
Table 2: Accessories
Number
Description
WG4WTS [1]
Outdoor-rated surface skirt, white, for Genesis WG4
horn or horn-strobe
WG4RTS [1]
Outdoor-rated surface skirt, red, for Genesis WG4
horn or horn-strobe
WG4GSKT [2]
Appliance replacement gasket, flush mount
[1] The trim skirt is outdoor-rated when used with the Model 449
electrical box.
[2] Not compatible with the trim skirts.
To synchronize horn-strobe operation, you must install a
separate synchronization source. See Table 3. When
connecting the horn-strobe to a listed control panel, verify
synchronization operation on the compatibility list for the
corresponding panel.
Table 3: Compatible synchronization source models
Description
Auto-sync output
module
Genesis signal master -
remote mount
Booster or auxiliary
power supply
* Represents any number of additional characters
Installation
Install this device in accordance with applicable requirements
and in accordance with the local authorities having jurisdiction.
1 / 10
Number
SIGA-CC1S
SIGA-MCC1S
GSA-CC1S
GSA-MCC1S
SIGA-CC2A
SIGA-MCC2A
ADTG1M-RM
MG1M-RM
EG1M-RM
XLSG1M-RM
G1M-RM
ZG1M-RM
APS10*
EBPS10*
APS6*
EBPS6*
BPS10*
MIRBPS10*
BPS6*
MIRBPS6*
EAPS10*
XLS-BPS10*
EAPS6*
XLS-BPS
P/N 3102000-ML • REV 1.0 • ISS 11APR12

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Genesis WG4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Edwards Genesis WG4

  • Page 1 Description connecting the horn-strobe to a listed control panel, verify synchronization operation on the compatibility list for the The Genesis WG4 Outdoor Horn-Strobe is a life safety corresponding panel. notification appliance designed for indoor or outdoor use on ceilings or on walls. See Table 1 for a list of models and Table 3: Compatible synchronization source models Table 2 for a list of accessories.
  • Page 2 11. Remove the strobe protective cover shown in Figure 3, • You can mount the Genesis WG4 Outdoor Horn-Strobe item 3. Do not touch the glass of the strobe tube horizontally or vertically on either the wall or ceiling; place underneath, as this may shorten the life of the glass tube.
  • Page 3: Maintenance

    Figure 3: Jumper, switch, and protective cap locations Figure 5: UL 1971 minimum light output (% of rating vs. angle) 5 10 (1) Angle (2) Percentage of rated output Note: Horizontal plot Maintenance Do not change the factory finish. Perform a visual inspection and an operational test twice a year, or as directed by the local authority having jurisdiction.
  • Page 4: Regulatory Information

    Continuous High 94.0 99.6 102.9 Regulatory information Continuous Low 92.8 97.2 98.6 Manufacturer Edwards, A Division of UTC Fire & Security Temporal High 96.5 100.5 104.2 Americas Corporation, Inc. Temporal Low 90.3 94.2 97.0 8985 Town Center Parkway, Bradenton, FL 34202, USA dBA = Decibels, A-weighted.
  • Page 5: Installation

    L’avertisseur sonore/stroboscope pour usage extérieur question. Genesis WG4 est un appareil de notification pour la sécurité des personnes, conçu pour une utilisation en intérieur ou en Tableau 3 : Modèles de sources de synchronisation compatibles extérieur et pour un montage au plafond ou sur un mur.
  • Page 6 protection de la surface du joint et appliquer Figure 1 : Positions de montage de l’avertisseur sonore/stroboscope précautionneusement le joint sur le WG4 avec le côté adhésif orienté vers l’appareil. L’appuyer fermement contre la surface arrière de l’appareil pour le positionner correctement.
  • Page 7: Entretien

    Figure 3 : Emplacements des cavaliers, du commutateur et du Figure 4 : Schéma du câblage couvercle de protection (1) Entrée – de l’avertisseur (4) Sortie – de sonore/stroboscope l’avertisseur (2) Entrée + de l’avertisseur sonore/stroboscope sonore/stroboscope (5) Sortie + de (3) Les marques indiquent la polarité...
  • Page 8: Caractéristiques Techniques

    Information réglementaire Continu élevé 94,0 99,6 102,9 Continu faible 92,8 97,2 98,6 Fabricant Edwards, A Division of UTC Fire & Security Temporel élevé 96,5 100,5 104,2 Americas Corporation, Inc. 8985 Town Center Parkway, Bradenton, FL Temporel faible 90,3 94,2 97,0 34202, USA dBA = décibels, pondérés A.
  • Page 9 Conformité à la Ce dispositif est conforme à la partie 15 des norme FCC règles FCC. Son fonctionnement est soumis aux deux conditions suivantes : (1) ce dispositif ne doit pas causer d’interférences nuisibles et (2) il doit accepter toutes les interférences reçues, y compris celles qui sont susceptibles d’entraîner un fonctionnement indésirable.
  • Page 10 10 / 10 P/N 3102000-ML • REV 1.0 • ISS 11APR12...

Table of Contents