Summary of Contents for CARDINAL DVM SYSWALL45 Series

  • Page 1 CARDINAL DVM Keypad Modules SYSBOXX SYSWALL45 SYSWALL50 Assembly and Configuration Instructions English Translation of the Original Operating Instructions 2/2020...
  • Page 2: Table Of Contents

    Table of contents Notices regarding these instructions and the manufacturer ......... 4 Keep these instructions available ................... 4 Design features of these instructions ................4 Copyright ........................5 Manufacturer’s address ....................5 Safety ........................6 Intended use ........................6 Basic safety instructions ....................6 Preventing material damage ...................
  • Page 3 Creating the configuration for keypad modules ............28 Commissioning keypad modules .................. 41 Concluding the configuration ..................44 Troubleshooting ..................... 45 Dismantling the product ..................46 Disposing of the product ..................47 Warranty declarations .................... 48...
  • Page 4: Notices Regarding These Instructions And The Manufacturer

    Notices regarding these instructions and the manufacturer These instructions will help you to use the "CARDINAL DVM Keypad Module" products safely. The "CARDINAL DVM Keypad Module" products are referred to as "product" in the following unless the functions require differentiation.
  • Page 5: Copyright

    Notices regarding these instructions and the manufacturer Copyright These instructions contain information that is subject to copyright. These instructions may not be copied, printed, filmed, processed, duplicated or distributed in any form, either in whole or in part, without the prior written permission of Sommer Cable GmbH.
  • Page 6: Safety

    Safety Safety Intended use The product is designed to control media devices (audio or video devices) with an RS232 interface at events and installations and in the broadcasting sector. The product is intended for use in closed buildings. Intended use also includes compliance with the accident prevention regulations and the statutory regulations and standards applicable at the place of use.
  • Page 7: Personnel Qualification

    Safety Personnel qualification The instructions are intended for assembly and configuration personnel. The following knowledge is required by assembly and configuration personnel: • Knowledge in computer, network and media technology • Knowledge and experience in assembly and configuration The modification of the power supply unit configuration may only be carried out after consultation with the manufacturer and by persons with the additional qualification of "qualified electrician".
  • Page 8: Description

    Description Description Scope of delivery Depending on the variant or order, the following parts are included in the scope of delivery: SYSWALL keypad modules • SYSWALL45/ 50 keypad module • 4 × keycap, clear • 1 × pre-perforated labeling sheet •...
  • Page 9: Optional Accessories

    • Adapter cable “DVM-194-C4-xxx” for connecting the power supply unit to the device to be controlled • Adapter cable “DVM-194-C5-xxx” for direct connection of the keypad module with the CARDINAL DVM HDBaseT built-in transmitters (e.g. DVM-194-HDBT-T or W45W-3455). Operation without a power supply unit is therefore possible.
  • Page 10: Syswall45 Keypad Module

    Description SYSWALL45 keypad module Designation Key for controlling third-party media device Detent Programming key with LED lighting USB port (type Mini-B) Port 2 (RJ45, output) Jumper for termination Port 1 (RJ45, input)
  • Page 11: Syswall50 Keypad Module

    Description SYSWALL50 keypad module Designation Key for controlling third-party media device Programming key USB port (type Mini-B) Port 2 (RJ45, output) Jumper for termination Port 1 (RJ45, input) Hole for fastening to SYSWALL system...
  • Page 12: Sysboxx Keypad Module

    Description SYSBOXX keypad module Designation Key for controlling third-party media device Port 1 (RJ45, input) Jumper for termination Port 2 (RJ45, output) USB port (type Mini-B) Programming key with LED lighting Hole for fastening to SYSBOXX system...
  • Page 13: Power Supply Unit

    Description Power supply unit Designation BUS 1 connection Plug-in screw terminal (COM 1), 3-pin Mains cable connection Plug-in screw terminal (COM 2), 3-pin BUS 2 connection Hole for fastening (to SYSBOXX system, desk or wall)
  • Page 14: Task And Function

    The keypad modules control individual functions of third-party media devices that have an RS232 interface. The desired control function is programmed using the “CARDINAL DVM Keypad Module System Configurator” software and transferred to the third-party media device via the RS232 interface by pressing a key on the module.
  • Page 15: Information On The Type Plate

    Description Information on the type plate The type plate is glued to the power supply unit housing. It contains the following information: • Type designation of the power supply unit • EAN code • Serial number • Disposal symbol • CE marking (The product complies with the standards listed in the enclosed declaration of conformity.) Technical data SYSWALL and SYSBOXX keypad modules...
  • Page 16: Storing And Transporting The Product

    Storing and transporting the product Storing and transporting the product  Store the product in its original packaging.  Transport the product in its original packaging.
  • Page 17: Unpacking The Product And Checking The Scope Of Delivery

    Unpacking the product and checking the scope of delivery Unpacking the product and checking the scope of delivery ATTENTION! The product contains components sensitive to electrostatic charge. These components may be damaged or destroyed by the effect of an electric field or by charge equalization when touched.
  • Page 18: Installing The Product

    Installing the product Installing the product ATTENTION! Material damage may be caused by using the product under incorrect operating conditions.  Install the product in a dust-free environment.  Install the product protected against moisture, vapors, splash water and wetness. ...
  • Page 19: Installing Sysboxx Keypad Modules

    Installing the product Installing SYSWALL50 keypad modules in a flush-mounted cavity box The following tool and materials are required for mounting: • Two screws (M2) • Screwdriver TX6 To install a SYSWALL50 keypad module in a flush-mounted cavity box, proceed as follows: ...
  • Page 20: Installing The Power Supply Unit

    Installing the product Installing the power supply unit The power supply unit can be installed in the following: • SYSBOXX system or • separately (e.g. on a desk or wall) The following tool and materials are required for mounting: • Four screws (M2.5) •...
  • Page 21 Installing the product Installing the power supply unit separately ATTENTION! Material damage may be caused by supplying power to the power supply unit during installation.  Before installation, make sure that the power supply unit is not connected to the power supply. You can also mount the power supply unit separately (under/on the desk or on the wall).
  • Page 22: Connecting The Product

    The keypad module in “standalone” mode can also be optionally connected to the “CARDINAL DVM HDBaseT transmitter” using the “DVM-194-C5” adapter cable. In this case, the HDBaseT transmitter supplies the keypad module with the required operating voltage. In this...
  • Page 23: Connecting The Keypad Modules For Bus Network Operation

    Connecting the product Connecting the keypad modules for bus network operation You can integrate up to 16 keypad modules into the system for bus network operation. The keypad modules can communicate via a central serial interface (COM 1) on the power supply unit. To do so, you must connect the keypad modules to the power supply unit and to each other using the network cables.
  • Page 24 Connecting the product The keypad modules in “bus network” mode can also be optionally connected to the “CARDINAL DVM HDBaseT transmitter” using the “DVM-194-C5” adapter cable. In this case, the HDBaseT transmitter supplies up to two slave modules with the required operating voltage. The master module is connected to the HDBaseT transmitter using the “DVM-...
  • Page 25: Attaching Keycaps To The Keypad Module

    Attaching keycaps to the keypad module Attaching keycaps to the keypad module ATTENTION! Damage to the keycaps may be caused by incorrect insertion or removal.  Insert the keycaps only according to these instructions.  Have the keycaps removed by the manufacturer only. You can attach the keycaps with labels before or after mounting on the keypad module.
  • Page 26: Configuring The Product

     Switch to the product page. To do so, type in the article number under “Search”.  To download the current version of the “CARDINAL DVM Keypad Module System Configurator” software, follow the instructions on the screen.  Install the software on your computer. In the process, follow the instructions...
  • Page 27 Configuring the product Installing the driver To install the driver, proceed as follows:  Call the Internet page of the manufacturer.  Switch to the product page.  To download the “STMicroelectroncs Virtual COM Port” driver, follow the instructions on the screen. ...
  • Page 28: Creating The Configuration For Keypad Modules

    Configuring the product Creating the configuration for keypad modules To create a configuration, proceed as follows:  Open the "CARDINAL DVM Keypad Module System Configurator" software on your computer. The main screen is displayed with the following options: Module settings...
  • Page 29 Configuring the product Configuration export Button for exporting and saving a configuration made in [Konfiguration export.]: the software or loaded from a keypad module Available modules in Here you can select the available keypad modules. bus network [Verfügbare Module im Verbund]: Search for available Here you can search for available keypad modules.
  • Page 30 Configuring the product To set the function of the keys, proceed as follows:  Click “Key assignment COM 1” [Tastenbelegung COM 1]. The following screen page is displayed: Contact type Button [Taster]: [Kontaktart]: The key functions as a button. If the LED is not independently controlled, it is switched on when pressed and the command stored when pressed is sent.
  • Page 31 Configuring the product You can set the function of the keys individually on the "Key assignment" [Key assignment] screen page. To do so, proceed as follows:  In the “Key assignment COM 1” [Tastenbelegung COM 1] section, select the contact type of the respective key. ...
  • Page 32 Configuring the product If the LED is to be controlled, e.g. by a higher-level system, proceed as follows:  Click “LED feedback COM 1” [LED-Feedback COM 1]. The “LED feedback COM 1” [LED-Feedback COM 1] screen is opened as shown. ...
  • Page 33 Configuring the product Entering the “Serial commands (outgoing)” [Serielle Befehle ausgehend] command guide These serial commands are output via the COM 1 interface when the key is pressed. The commands are formated as follows: • The entry is made in ASCII format. •...
  • Page 34 Configuring the product Creating a configuration for the bus network To create a configuration for the bus network, proceed as follows:  On the start screen, click the “Bus network” [Busverbund] operating mode. The screen page with the modules available in the network (e.g. master module) is displayed.
  • Page 35 Configuring the product The “Master module” [Master-Modul] menu item is highlighted in blue.  In the “Metadata” [Metadaten] field, enter information such as the operating mode, number of the desktop connection panel, etc.  In the “Serial interface” [Serielle Schnittstellen] fields, enter the respective connection parameters for COM 1 according to the manual of the third-party media device to be controlled.
  • Page 36 Configuring the product To set the function of the keys, proceed as follows:  Click the “Key assignment [Tastenbelegung] option. The following screen page is displayed:...
  • Page 37 Configuring the product Contact type Button [Taster]: [Kontaktart]: The key functions as a button. If the LED is not independently controlled, it is switched on when pressed and the command stored when pressed is sent. When the key is released, the LED is switched off and the command stored at release is sent.
  • Page 38 Configuring the product You can set the function of the keys individually here. To do so, proceed as follows:  Select the contact type [Kontaktart] of the respective key.  Enter the serial commands for the respective key in the corresponding fields.
  • Page 39 Configuring the product If the LED is to be controlled, e.g. by a higher-level system, proceed as follows:  Click the “LED feedback” [LED-Feedback] option. The “LED feedback” [LED-Feedback] screen is opened as follows. LED ON/OFF/flashing The input buffer of the serial interface is compared with [LED an/aus/blinken]: the entries in the fields.
  • Page 40 Configuring the product Removing a slave module If you want to remove a slave module from the bus network, proceed as follows:  Left-click the slave module to be deleted. The selected keypad module is highlighted in color.  Now right-click the selected slave module again. The selection menu appears.
  • Page 41: Commissioning Keypad Modules

    Configuring the product Commissioning keypad modules Before commissioning keypad modules, proceed as follows:  Make sure the right driver version is loaded. To be certain, check it in the Windows Device Manager.  Make sure you have entered a complete configuration. To commission the keypad modules, you must carry out the following activities: •...
  • Page 42 Configuring the product Transferring (writing) the configuration to the keypad module When you have completely created the configuration for a keypad module (standalone or master), you can transfer (write) it from the software to the keypad module. Proceed as follows: ...
  • Page 43 Configuring the product Addressing slave modules After the configuration has been successfully written to the master module and the master module has been restarted, you must address the slave modules. To address them, the configuration currently on the master module must be loaded into the software.
  • Page 44: Concluding The Configuration

    Configuring the product Deleting the address of a slave module To delete the address of a slave module, proceed as follows:  Make sure that the keypad modules in the bus network are correctly cabled (see page 23).  Make sure the programming key flashes green for all modules. ...
  • Page 45: Troubleshooting

    Troubleshooting Troubleshooting Remedy Problem Possible cause The software cannot Keypad modules not  Make sure that the keypad find an available connected to power module is connected to the module, even though it supply unit power supply unit and that the is displayed in the power supply unit is connected Windows Device...
  • Page 46: Dismantling The Product

    Dismantling the product Dismantling the product To dismantle the product, proceed as follows:  Disconnect the mains plug.  Remove the network cable from the keypad module.  To disassemble the product, proceed in the reverse order of installation. Installing the product For more information, see the section as of page 18.
  • Page 47: Disposing Of The Product

    Disposing of the product Disposing of the product At the end of its service life, you must dispose of the product and its accessories in an environmentally friendly manner.  Return the product to the manufacturer in its original packaging. ...
  • Page 48: Warranty Declarations

    Warranty declarations Warranty declarations Sommer Cable GmbH grants a manufacturer's warranty of two years from the date of purchase (proof of purchase receipt) on all parts included in the scope of delivery within the scope of legal regulations. Improper handling or incorrect use shall exempt liability for defects.