6. Technical specifications

6.1 European explosion protection

ATEX ( CN3(e) ATEX):
ATEX ( CN4(e) ATEX):
EC type approval test certificate
Interconnection of devices:
Designation / ambient
temperature range
CN3 ATEX,
CN3e ATEX
--.--
II 3G Ex ic IIC T4
II 3D Ex icD 22 T130°C
Ta -20°C...+50°C
18
II 3G Ex ic IIC T4
II 3G Ex ic op is IIC T4
II 3D Ex icD 22 T130 °C
EPS 09 ATEX 1 222 X
Designation / ambient
temperature range
CN4 ATEX,
CN4e ATEX
II 3G Ex ic op is IIC T4
II 3D Ex icD 22 T130°C
--.--
Ta -20°C...+50°C
Snap-On RFID 510 -Ex
(suitable for)
(
II 3G Ex ic IIC T4)
(
II 3G Ex ic IIC T4)
Ta -20°C...+50°C
Designation / ambient
temperature range of the
overall system:
(CNx(x) ATEX +
Snap-On RFID 510 -Ex)
II 3G Ex ic op is IIC T4
II 3G Ex ic IIC T4
Ta -20°C...+50°C