RJ45 Connector for Audio/Video
To build your own A/V RJ45 connectors, please follow the
PIN-OUTS shown below.
NOTE: TPT1040 Wiring
CAT5e network cable with RJ45 connectors.
Romex or equivalent 120-220VAC power supply*
Each TPT1040 may also have up to four A/V cables
using CAT5e with RJ45 connectors and an A/V
Connector Cable – part number VDA-0176 shown above
– on the A/V end.
*See the TPT1040-INSTALL-16 sheet
VDA-0176 A/V Connector Cable
The TPT1040-INSTALL-16 kit ships with one VDA-0176 A/V
connector cable. Additional cables may be purchased from
Vantage Controls. This cable connector is designed to connect
directly to the A/V equipment using the RCA connectors. Use
a straight through RJ45 (female) coupler allowing the installer
to run longer CAT5e wire runs with male, RJ45 type
connectors to the TPT1040 and the VDA-0176 connector
cable. A/V wire runs should not exceed 200ft. Please see the
TPT1040-INSTALL-16 install sheet for details.
SD Memory Card
For most applications the built-in memory will be sufficient.
However, the TPT1040 allows an SD Memory card to be
inserted if it is anticipated that the design will require more
than the default memory. Erase the current program on the
TPT1040 first (see TPT1040 System Screen above).
NOTE: To avoid possible configuration issues, power down the
TPT1040 when inserting or removing the SD Memory Card.
Reprogram the TPT1040 after inserting an SD Memory card.
39755 / InFusion compatible
Connection Status Indicator
In the Configuration screens mentioned earlier, notice the
round highlighted indicator in the upper right hand corner. This
indicator changes appearance to indicate the connection
status of the TPT1040. Use this indicator to help trouble shoot
issues if the screen appears to have connection issues. The
indicator changes colors as indicated below.
Indicator
Color
Green
Connected and properly configured
Connected to controller but not properly
Amber
configured on the controller
Grey
Not connected to a controller
Red
Ethernet disconnected
Trouble Shooting Tips
Problem
The design application may be corrupted.
Touch toward the outside edge of the screen,
the instant the loading spinner displays. A
TPT1040
message will pop-up asking, "Do you wish to
Continually
start up without loading configuration?" To
Reboots
abort the design application from loading
click OK. A new design application may now
be downloaded to the screen from Design
Center.
From the Boot Loader Screen (see Reset
Can't Erase
above) press the hard buttons in this order:
The Screen
LEFT & RIGHT (simultaneously)
From The
-then-
Configure
LEFT | RIGHT | RIGHT | LEFT
System
When the screen is reset it should be back to
Menu
factory settings
Connection Status
Solution