FIRE/503 WATER-N
ELECTRONIC CONTROLLER FOR
FIREPLACES

INTRODUCTION

We thank you for your trust and congratulate you for choosing
one of our products. This device is a BUILT-IN ELECTRONIC
CONTROLLER FOR FIREPLACES that manages four devices
through microprocessor logic: two circulators, one diverter
valve and one auxiliary output.

COMPLIANCE WITH STANDARDS:

EN 60730-1 as subsequently amended
EN 60730-2-7
EN 60730-2-9

COMPLIANCE WITH DIRECTIVES:

B.T. 73/23/EEC
E.M.C. 89/336/EEC
as subsequently amended CE 93/68/EEC

TECHNICAL CHARACTERISTICS

POWER SUPPLY = 230Va.c./50Hz (+10%-15%)
TEMPERATURE PROBE = NTC 1%
MAXIMUM PROBE TEMPERATURE = 150°C
OPERATING TEMPERATURE = 0÷50°C
STORAGE TEMPERATURE = 0÷60°C
OPERATING HUMIDITY = 10%÷90% with no condensate
ADJUSTMENT = with relays (I max. = 3A)
ABSORBED POWER = 1VA
LCD DISPLAY
TEMPERATURE DISPLAY = 5÷85°C (1°C resolution)
DEGREE OF PROTECTION = IP20 (installed product)
INSTALLATION CONDITIONS = normal environment
ASSEMBLY = in standard 3–module flush-mounted box DIN503
NON-VOLATILE DATA STORAGE ON FLASH TECHNOLOGY
KEYPAD = in rubber with 8 keys
BUZZER internal for alarm signalling

CONTROLS LEGEND

+ / - keys
Increases or decreases the selected value
SET key
Enables the SET Point function
E key
Enables the Enter function
A key
Enables the Automatic function
T button
Press T to store the new parameters
OFF key
Press OFF to turn off the controller
DIMENSION
Fig. 1
MI07A592-Rev1011-GB
Fig. 2

INSTALLATION AND CONNECTIONS

SAFETY INSTRUCTIONS
Before you connect the controller to the mains, make
sure that voltage is CUT OUT and that it corresponds
to a value of 230Va.c. (Fig. 3).
Fig. 3
The fireplace must be connected to the mains, with a line
differential main switch, in compliance with regulations
in force.
Make sure that the electrical characteristics of the motor to be
controlled are compatible with those of the product (Imax=3A).
The manufacturer is not liable for improper use of the device.

POSITIONING

Do not install in places where temperature can exceed
40°C (Fig.4)
Fig. 4
Make sure the box is expressly intended to contain the
product only, and that it is NOT used as a shunt (Fig.5)
Fig. 5

INSTALLATION

A) Connect the wires to the terminal boards as shown in the
electrical diagram (see paragraph "electrical wirings" and
"application diagram" below)
B) Fit the controller inside the 3-module box previously
mounted within the wall, and secure everything using the
screws supplied with the product
Fig. 6
1/4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FIRE/503 WATER-N and is the answer not in the manual?

Questions and answers

Summary of Contents for Imit FIRE/503 WATER-N

  • Page 1 FIRE/503 WATER-N ELECTRONIC CONTROLLER FOR FIREPLACES Fig. 2 INTRODUCTION We thank you for your trust and congratulate you for choosing INSTALLATION AND CONNECTIONS one of our products. This device is a BUILT-IN ELECTRONIC CONTROLLER FOR FIREPLACES that manages four devices...
  • Page 2 C) Assemble the desired PLAQUE by pressing it in. In case you choose to fit a PLAQUE from the “LIVING INTERNATIONAL”, “PLAYBUS” “PLAYBUS YOUNG” series, you need to break off and throw away the two tabs on the sides of the front panel (Fig.7). Fig.
  • Page 3 Frost-protection function: when probe TURNING OFF THE CONTROLLER – OFF mode temperature falls below the value set in parameter P17 ( default 5°C – see parameter table), the following conditions have to occur : The OFF mode is entered when you •...
  • Page 4 “TEST” MODE Table 2 PARAMETERS CODE MIN PRE-SET MAX Enter the TEST mode by pressing the T C1 circulator differential 2°C 4°C 8°C key. In this mode, the display shows: EV Solenoid valve differential 2°C 4°C 8°C • The word “OFF” (at the bottom AUX output differential 2°C 4°C...