Download Print this page

Schweizer MSP-FR-EW Mounting Instructions

Solar systems, flat roof pv mounting system

Advertisement

Quick Links

Solar systems of Schweizer:
Mounting instructions – MSP-FR-EW flat
roof PV mounting system
Legend to mounting instructions
Observe additional information
proMSP
!
Caution: check carefully
Correct operation
Incorrect operation
© Ernst Schweizer AG
Ernst Schweizer AG, Metallbau
CH-8908 Hedingen
Telefon +41 44 763 61 11
Telefax +41 44 763 61 19
www.schweizer-metallbau.ch
Audible clicking sound
Mounting direction of part
Tool type / required torque
Part identification
Mounting instructions - MSP-FR-EW
technical changes reserved
27.03.2015/BRX
page 1/12

Advertisement

loading

Summary of Contents for Schweizer MSP-FR-EW

  • Page 1 Solar systems of Schweizer: Mounting instructions – MSP-FR-EW flat roof PV mounting system Legend to mounting instructions Observe additional information Audible clicking sound proMSP Caution: check carefully Mounting direction of part Correct operation Tool type / required torque Incorrect operation Part identification ...
  • Page 2 Observance of the information provided in these installation instructions is included in the definition of the in- tended use. Schweizer cannot be held liable for damage or loss resulting from the failure to observe these installation ins- tructions, especially the safety instructions, or through misuse of the product.
  • Page 3 This should be tested by an appropriate specialist. − The Schweizer MSP-FR-EW system may be included in the design of, and connected to, the electrical po- tential equalization system, by correctly fitting a suitable earthing clamp or screw (not supplied by Schwei- zer).
  • Page 4: Installation Conditions

    − For panels that permit clamping on the short edges in the corner location (Schweizer can provide a list of approved panels on request). Schweizer is not responsible for ensuring the continued validity of the war- ranty provided by the panel manufacturer.
  • Page 5: Installation

    3. Screw the low support (MSP-FR-EW-SL, ) into place using a screw (MSP-FR-S, ) with a torque of 10 Nm. Only one screw is needed per support.
  • Page 6 2. Following the details in the software report, measure out the position of the starting lower support (MSP- FR-EW-SL, ) and place it appropriately. Note: Ensure the correct base profile (MSP-FR-EW-BP, ) length is used (it will be the shorter one if two lengths are being used).
  • Page 7 1. Under the location of every PV panel to be installed, a grounding screw (MSP-FR-GS, ) must be ins- talled onto that lip of the low support (MSP-FR-EW-SL, ). 2. Where no PV panel will be in contact with a lip of a low support (MSP-FR-EW-SL, ), a grounding screw (MSP-FR-GS, ) is not required.
  • Page 8 Fig. 26: Grounding PV installation Note: The equipment required for this step is not supplied by Schweizer. The method indicated is only a sug- gestion, there are numerous ways to achieve this. The customer must decide how best to achieve a ground- ing of the PV system.
  • Page 9 Solar Energy Systems Mounting instructions – MSP-FR-EW flat roof PV mounting system MSP-FR-EW-SH MSP-FR-EW-SL MSP-FR-EW-BP ... MSP-FR-EW-C MSP-FR-EW-PSF MSP-PR-EC MSP-PR-MC MSP-FR-S M6x60 MSP-FR-GS 6x60 MSP-FR-CH8 proMSP Ernst Schweizer AG, Metallbau Mounting instructions - MSP-FR-EW CH-8908 Hedingen technical changes reserved Telefon +41 44 763 61 11 27.03.2015/BRX...
  • Page 10 Solar Energy Systems Mounting instructions – MSP-FR-EW flat roof PV mounting system proMSP proMSP proMSP proMSP PROFIS proMSP Solar Ernst Schweizer AG, Metallbau Mounting instructions - MSP-FR-EW CH-8908 Hedingen technical changes reserved Telefon +41 44 763 61 11 27.03.2015/BRX Telefax +41 44 763 61 19 ©...
  • Page 11 Solar Energy Systems Mounting instructions – MSP-FR-EW flat roof PV mounting system proMSP proMSP proMSP Ernst Schweizer AG, Metallbau Mounting instructions - MSP-FR-EW CH-8908 Hedingen technical changes reserved Telefon +41 44 763 61 11 27.03.2015/BRX Telefax +41 44 763 61 19 ©...
  • Page 12 Solar Energy Systems Mounting instructions – MSP-FR-EW flat roof PV mounting system Ernst Schweizer AG, Metallbau Mounting instructions - MSP-FR-EW CH-8908 Hedingen technical changes reserved Telefon +41 44 763 61 11 27.03.2015/BRX Telefax +41 44 763 61 19 © Ernst Schweizer AG www.schweizer-metallbau.ch...