Quick Security Technology (QST)
Smart AWC touch uses QST for real-time protection against any failure situation.*
QST can detect the malfunction of the sensor the controller, and the empty
reservoir to avoid the pump running dry. The controller will give an audible and
visual alert when any one of the following situations occurs.
For
ATO: Any refilling time is 3 times longer than the first refilling time.
For example, if the first refilling time is 10 sec, the controller will give an alert
when any refilling time is over 30 sec.
For
AWC: Any draining time or refilling time is 3 times longer than the first one.
For example, if the first draining or refilling time is 20 sec, the controller will give
an alert when any draining or refilling time is over 60 sec.
*1. No security time control for the first refilling and draining.
2. The minimum security time for ATO refilling is 10 sec, while the minimum security time for
AWC draining or refilling is 20 sec.
How to Reset?
Reset : Holding
to clear the QST memory (the first draining time and
the first refilling time).
After reset, please unplug and replug the power cable.
11
for at least 8 sec is the only way