5. operation
5.1.
assembly
5.1.1.
check that no component is missing.
5.1.2.
Fix castors to base unit using bolts supplied and position base unit diagram 1.
5.1.3.
Secure hydraulic unit to base unit using bolts supplied diagram 2.
5.1.4.
attach handle and support by sliding over end of hydraulic unit diagram 3.
5.1.5.
Assemble release pedal diagram 4.
5.1.6.
Assemble the lifting pedal diagram 5 and 6
5.1.7.
Take care in removing transport pin so as not to trap fingers diagram 7.
5.2.
operation
5.2.1.
prior to using the jack air will need to be eliminated from the hydraulic system. to do this help from another person is recommend
to apply pressure to the release pedal, simultaneously hold the jack by the handle and apply pressure on the lifting pedal. then by
releasing the release pedal the jack is ready for operation.
5.2.2.
fix the position of the jack in relation to the gearbox or part to be removed so that when the piston is lifted, the stand is centred.
5.2.3.
prior to proceeding with the lowering, installation or movement of the gearbox, it is necessary to secure it on the lifting stand.
5.2.4.
the jack support is lifted by applying pressure/pumping the lifting pedal and lowered by applying pressure on the release pedal. to
prevent jerky motion when lowering the jack is fitted with a system which regulates and controls the lowering operation.
WarninG! prior to each use, check for bent, broken, cracked or loose parts and withdraw the jack from service if it is suspected that
the jack has been subjected to abnormal loads or has suffered any knocks.
once the jack has been used , the piston should be fully retracted to avoid corrosion.
6. maintenance
6.1.
Maintenance and repair should only be carried out by a qualified person.
6.2.
clean and lubricate the moving parts of the jack at regular intervals. the jack should be kept clean and protected from aggressive
conditions at all times.
6.3.
If the oil level needs to be checked or refilled, proceed as follows: With the jack in the vertical position and the piston fully retracted,
remove the filler plug, which is indicated with a star, and drain its contents into a container. Position the jack in a horizontal position,
proceed to introduce the necessary volume indicated in the table. Then reinsert the filler plug. An excess of oil over the volume
required may affect the operation of the jack.
6.4.
Only use hydraulic oil, HL or HM type, with an ISO grade of cinematic viscosity of 30cSt at 40
Never use brake fluid.
6.5.
following a period of prolonged intensive use, it is recommended to change the oil in order to extend the useful life of the jack.
6.6.
When the jack is not in use, the piston should be fully retracted to avoid corrosion. It is recommended to apply an anti-corrosion
product to the main piston and particularly to the pump. store the device in a dry, clean place out of the reach of children.
6.7.
at the end
3.5. following a period of prolonged intensive use, it is recommendable to change the oil in order to extend the useful life of the jack.
3.6. When the jack is not in use, the piston should be fully retracted to avoid corrosion. However, it is recommendable to apply an anti-
corrosion product to the main piston and particularly to the pump. store the device in a dry, clean place, out of the reach of children.
3.7. at the end of the useful life of the jack, drain off the oil and hand it over to an authorised agent and dispose of the remaining parts in
accordance with local regulations.
parts support is available for this product. to obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or telephone 01284 757500.
environmental protection
recycle unwanted materials instead of disposing of them as waste. all tools, accessories and packaging should be
sorted, taken to a recycling centre and disposed of in a manner which is compatible with the environment.
when the product becomes completely unserviceable and requires disposal, drain off any fluids (if applicable)
into approved containers and dispose of the product and the fluids according to local regulations.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
important: no liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
© Jack sealey limited
sole uK distributor, sealey group.
Kempson way, suffolk Business park,
Bury st. edmunds, suffolk.
iP32 7AR
Original Language Version
c or of an engler viscosity of 3 at 50
o
01284 757500
01284 703534
pTJ30,PTJ75,PTJ120 | Issue 1 16/08/16
c.
o
www.sealey.co.uk
sales@sealey.co.uk

Advertisement

loading

This manual is also suitable for:

Ptj75Ptj120