Sign In
Upload
Download
Add to my manuals
Delete from my manuals
Share
URL of this page:
HTML Link:
Bookmark this page
Add
Manual will be automatically added to "My Manuals"
Print this page
×
Bookmark added
×
Added to my manuals
Manuals
Brands
Kaldewei Manuals
Plumbing Product
NEXSYS-SYSTEM
Planning instructions
Kaldewei NEXSYS-SYSTEM Planning Instructions
Hide thumbs
1
2
3
4
5
6
7
8
9
10
11
12
13
page
of
13
Go
/
13
Bookmarks
Advertisement
Quick Links
Download this manual
NEXSYS-SYSTEM
Content
GB Planning Instructions
Table of
Contents
Previous
Page
Next
Page
1
2
3
4
5
Advertisement
Need help?
Do you have a question about the NEXSYS-SYSTEM and is the answer not in the manual?
Ask a question
Questions and answers
Subscribe to Our Youtube Channel
Related Manuals for Kaldewei NEXSYS-SYSTEM
Plumbing Product Kaldewei CENTRO Installation Instructions Manual
(20 pages)
Plumbing Product Kaldewei 5037 Assembly Instructions
Special supporting frame (4 pages)
Plumbing Product Kaldewei Saniform Plus Instructions For Use
(4 pages)
Plumbing Product Kaldewei KA 4040 Installation Instructions
(2 pages)
Plumbing Product Kaldewei SILENIO Installation Instructions Manual
(20 pages)
Plumbing Product Kaldewei FLOWLINE ZERO Operating Instructions
(2 pages)
Plumbing Product Kaldewei SILENIO0 Installation Instructions Manual
(16 pages)
Plumbing Product Kaldewei 5200 Installation Instruction
Universal shower tray feet (3 pages)
Summary of Contents for Kaldewei NEXSYS-SYSTEM
Page 1
NEXSYS-SYSTEM Content GB Planning Instructions...
Page 2
Slope of the Showertray-System Installation Situation Systemcomponents Waste Fitting 2.1.1 Drainage Capacity Showertray-System Design-Cover Installation Requirements Position Waste Fitting Height Adjustment Slope of the Showertray-System Installation Sequence Installation Situation 2/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 3
Content Installation Situation Position Waste Fitting Installation Sequence Systemcomponents Height Adjustment Installation Requirements Slope of the Showertray-System 1.0 Installation Situation Systemcomponents 3/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 4: System Components
Position Waste Fitting Installation Sequence Waste Fitting Systemcomponents Height Adjustment Showertray-System Installation Requirements Slope of the Showertray-System Design-Cover 2.0 Systemcomponents Waste Fitting Showertray-System Design-Cover KA 4121 KA 4122 Installation Requirements 4/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 5
(mm) AH (mm)* Showertray-System 1000 1000 1200 1200 Design-Cover 1400 1400 1600 1600 * = Actions for sound insulations might influence the installation height (AH). Inch = mm x 0,0394 5/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 6: Drainage Capacity
0,45 l/s (0,43 l/s) 0,50 l/s (0,48 l/s) max. EBH 70 mm 0,56 l/s (0,48 l/s) 0,61 l/s (0,55 l/s) (with Hair Catcher) (with Hair Catcher) Inch = mm x 0,0394 6/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 7
Cut Protection Tape 2615 1000 1000 2617 1200 Waste Fitting 2618 1200 2619 1000 1200 2623 1400 Design-Cover 2624 1000 1400 2626 1600 Inch = mm x 0,0394 7/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 8
NEXSYS for 900mm length of sower surface, Mod. 4133 806,5 6877 7124 0969 Requirements NEXSYS for 1000mm length of sower surface, Mod. 4134 906,5 6877 7125 0969 Inch = mm x 0,0394 8/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 9
(mm) 2612 2615 1000 1000 2617 1200 2618 1200 2619 1000 1200 2623 1400 Position Waste Fitting 2624 1000 1400 2626 1600 Inch = mm x 0,0394 9/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 10
4.0 Position Waste Fitting ≥ 1˚ 75 mm KA 4121 EH - X = >80 mm AH - H = >80 mm Height Adjustment 90° Inch = mm x 0,0394 10/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 11: Height Adjustment
≈ 0,5 mm ≈ 1 mm Thickness of the Tiling System "FA" (mm) H (mm) X (mm) 1000 1200 Slope of the 1400 Showertray-System 1600 Inch = mm x 0,0394 11/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 12
Installation Requirements Slope of the Showertray-System 6.0 Slope of the Showertray-System 75 mm b (mm) T (mm) 1000 1200 Installation 1400 Sequence 1600 Inch = mm x 0,0394 12/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Page 13: Installation Sequence
Beckumer Str. 33-35 D-59229 Ahlen +49 2382 785 0 +49 2382 785 200 www.kaldewei.com 287.629 / 01.2018 287.629 / 01.2018 | NEXSYS | © KALDEWEI.COM | 1/4 13/13 | © KALDEWEI.COM | NEXSYS-SYSTEM Planning Instructions | 287.881 / 05.2018...
Print
Rename the bookmark
Delete bookmark?
Delete from my manuals?
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL
Need help?
Do you have a question about the NEXSYS-SYSTEM and is the answer not in the manual?
Questions and answers