RFtoo RF37GS User Manual

Dual band adjustable repeater for ps800/700 system

Advertisement

Quick Links

USER MANUAL
Dual Band Adjustable Repeater
PS800/700 System

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RF37GS and is the answer not in the manual?

Questions and answers

Summary of Contents for RFtoo RF37GS

  • Page 1 USER MANUAL Dual Band Adjustable Repeater PS800/700 System...
  • Page 2: Quick Start

    BS: Donor antenna port, uplink and downlink signals to base station. MS: Service antenna port, uplink and downlink signals to mobiles. *The picture is only for reference, please make the object as the standard. Guangzhou RFtoo Co., Ltd. info@rftoo.com 2 / 16...
  • Page 3: Wall Mount Method

    Limit the Functionality, Permanently or Temporarily, of Any REPEATER Structure Are Prohibited. Place donna Antenna and service Antenna in reverse, and guarantee at least the horizontal distance is 10 meters and vertical distance 3 meters. Guangzhou RFtoo Co., Ltd. info@rftoo.com 3 / 16 www.rftoo.com...
  • Page 4: Section 1 Product Description And List Of

    Heatsink convection cooling and low power consumption  Built-in ALC provides stable output power even when the handheld is close to the repeater to minimize the interference to the donor site Guangzhou RFtoo Co., Ltd. info@rftoo.com 4 / 16 www.rftoo.com...
  • Page 5: Section 2 System Diagram

    ≤1.5 ≤1.5 Max. Input Power Without Over Drive -20dBm -20dBm 1 ~ 10dB ∣△∣≤1dB ∣△∣≤1dB ATT step of 1 dB 10 ~ 20dB ∣△∣≤1dB ∣△∣≤1dB (PS800) 20 ~ 30dB ∣△∣≤1.5dB ∣△∣≤1.5dB Guangzhou RFtoo Co., Ltd. info@rftoo.com 5 / 16 www.rftoo.com...
  • Page 6 Display and Set LCD and Key Frequency Range DL Output Power Display content Gain Alarm Temperature Power Consumption ≤220W RF Connector N-Female Environment Conditions IP65 Humidity < 90% -30℃~+55℃ Operating Temperature Guangzhou RFtoo Co., Ltd. info@rftoo.com 6 / 16 www.rftoo.com...
  • Page 7: Section 4 Installation Instruction

    M10x60mm Screw with wallboard anchor Customer Manual* * Factory may choose to ship the product along with a hardcopy of this manual or make it available electronically through website download or email. Guangzhou RFtoo Co., Ltd. info@rftoo.com 7 / 16 www.rftoo.com...
  • Page 8 Donor antenna is typically installed on the rooftop or outside wall with high elevation, avoiding any obstacle and in line of sight with the base station antenna. The positions and number of service antennas must be designed properly by a qualified Guangzhou RFtoo Co., Ltd. info@rftoo.com 8 / 16...
  • Page 9 -48dBm. 5.2.1 Adjust the donor antenna direction until the “Alarm” indicator just change from green to orange. 5.2.2 Connect the donor antenna port to the REPEATER “BS” port. Guangzhou RFtoo Co., Ltd. info@rftoo.com 9 / 16 www.rftoo.com...
  • Page 10 Repeat the walk test until the coverage is acceptable. Document and report to project manager and system design engineer on the gain value settlement. Document the installation and test reports, and submit to project manager for approval. Guangzhou RFtoo Co., Ltd. info@rftoo.com 10 / 16 www.rftoo.com...
  • Page 11: Section 5 Safety Information And Regulations

     It is your responsibility to ensure the use of REPEATER complies with FCC and other regulations.  Do not power on the REPEATER before BS and MS ports are connected. Guangzhou RFtoo Co., Ltd. info@rftoo.com 11 / 16 www.rftoo.com...
  • Page 12: Section 6 Notices

    If the red indicator does not disappear, or the red indicator disappears only if both uplink and downlink ATT switches are on, this indicates that there is no sufficient isolation between the donor antenna and service antennas. Guangzhou RFtoo Co., Ltd. info@rftoo.com 12 / 16...
  • Page 13: Section 7 Troubleshooting

    The equipment is broken, PLL unlocking No light Green Please contact supplier temperature alarm No light UL and PL power amplifier will turn off light blinks Primary-slave Green communication Green light blinks exception Guangzhou RFtoo Co., Ltd. info@rftoo.com 13 / 16 www.rftoo.com...
  • Page 14: Section 8 Led Display Panel Of Operations Guide

    1. Click “UL” or “DL”, click “OK”,Then you can see the frequency, click “OK” again, click “+” or “-” Setting the frequency range which you want and click “OK” finish. Click “M” back to Main Menu. Guangzhou RFtoo Co., Ltd. info@rftoo.com 14 / 16 www.rftoo.com...
  • Page 15 When the display power is above standard, displayed as “+++”. 3. Click “GAIN”, click “OK”, real-time inquiry Uplink gain and downlink gain, click “+” or “-”,then setting gain which you want. click “OK” finish. click “M” back to Main Menu. Guangzhou RFtoo Co., Ltd. info@rftoo.com 15 / 16 www.rftoo.com...
  • Page 16 (1)DL Output > 27dBm, OK change to Alarm; (2)ALC work > 25dB, OK change to Alarm; (3)The display shows the real-time temperature, if the temperature goes beyond the up limit, displayed as “Alarm”. Guangzhou RFtoo Co., Ltd. info@rftoo.com 16 / 16 www.rftoo.com...

This manual is also suitable for:

Ps7080

Table of Contents