Kontron MicroTCA OM6040D User Manual
Kontron MicroTCA OM6040D User Manual

Kontron MicroTCA OM6040D User Manual

Four slot,double full-size, single-tier cube shelf

Advertisement

Quick Links

» User Guide «
OM6040D
MicroTCA™ Four Slot,
Double Full-size, Single-Tier
Cube Shelf
Doc. ID: 1038-6516, Rev. 1.0
July 13, 2010
If it's embedded, it's Kontron.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MicroTCA OM6040D and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Kontron MicroTCA OM6040D

  • Page 1 » User Guide « OM6040D MicroTCA™ Four Slot, Double Full-size, Single-Tier Cube Shelf Doc. ID: 1038-6516, Rev. 1.0 July 13, 2010 If it’s embedded, it’s Kontron.
  • Page 2: Imprint

    Disclaimer Copyright © 2010 Kontron AG. All rights reserved. All data is for information purposes only and not guaranteed for legal purposes. Information has been carefully checked and is believed to be accurate; however, no responsibility is assumed for inaccuracies. Kontron and the Kontron logo and all other trademarks or registered trademarks are the property of their respective own- ers and are recognized.
  • Page 3: Table Of Contents

    OM6040D Preface Table of Contents Revision History ......................ii Imprint ........................ii Disclaimer ........................ii Table of Contents ...................... iii List of Tables ......................v List of Figures ......................vii Proprietary Note ......................ix Trademarks .......................ix Environmental Protection Statement .................ix Explanation of Symbols .....................x For Your Safety ......................xi Temperature and High Voltage Safety Instructions ..........xi Special Handling and Unpacking Instructions ............xi General Instructions on Usage ................
  • Page 4 Preface OM6040D 3.3 Prerequisites ....................3 - 5 3.3.1 Cooling ....................3 - 5 3.3.2 Filler Panels ..................3 - 5 3.4 Mounting ....................3 - 6 3.5 Adding or Replacing OM6040D Components ..........3 - 6 3.6 Cooling Air Filter Maintenance ..............3 - 6 3.7 AMC Connector Mating Cycles ..............3 - 6 Page iv ID: 1038-6516, Rev.
  • Page 5: List Of Tables

    OM6040D Preface List of Tables OM6040D Shelf Specifications ..............1 - 5 Standards ....................1 - 7 Related Publications ................1 - 8 OM6040D Base Solution Configuration ........... 3 - 3 ID: 1038-6516, Rev. 1.0 Page v...
  • Page 6 Preface OM6040D This page has been intentionally left blank. Page vi ID: 1038-6516, Rev. 1.0...
  • Page 7: List Of Figures

    OM6040D Preface List of Figures OM6040D Shelf - Perspective View with Feet and Mounting Brackets ... 1 - 4 OM6040D Shelf - Front View ..............2 - 4 OM6040D Shelf - Back View ..............2 - 5 OM6040D Shelf - Bottom View ..............2 - 6 OM6040D Shelf - Top View ..............
  • Page 8 Preface OM6040D This page has been intentionally left blank. Page viii ID: 1038-6516, Rev. 1.0...
  • Page 9: Proprietary Note

    Preface Proprietary Note This document contains information proprietary to Kontron. It may not be copied or transmitted by any means, disclosed to others, or stored in any retrieval system or media without the prior written consent of Kontron or one of its authorized agents.
  • Page 10: Explanation Of Symbols

    Preface OM6040D Explanation of Symbols Caution, Electric Shock! This symbol and title warn of hazards due to electrical shocks (> 60V) when touching products or parts of them. Failure to observe the pre- cautions indicated and/or prescribed by the law may endanger your life/health and/or result in damage to your material.
  • Page 11: For Your Safety

    However, the life expectancy of your product can be drastically reduced by im- proper treatment during unpacking and installation. Therefore, in the interest of your own safety and of the correct operation of your new Kontron product, you are requested to conform with the following guidelines.
  • Page 12: General Instructions On Usage

    OM6040D General Instructions on Usage In order to maintain Kontron’s product warranty, this product must not be altered or modified in any way. Changes or modifications to the device, which are not explicitly approved by Kontron and described in this manual or received from Kontron’s Technical Support as a special han- dling instruction, will void your warranty.
  • Page 13: Two Year Warranty

    As a result, the products are sold “as is,” and the responsibility to ensure their suitability for any given task remains that of the purchaser. In no event will Kontron be liable for direct, indirect or consequential damages resulting from the use of our hardware or software products, or documentation, even if Kontron were advised of the possibility of such claims prior to the purchase of the product or during any period since the date of its purchase.
  • Page 14 Preface OM6040D This page has been intentionally left blank. Page xiv ID: 1038-6516, Rev. 1.0...
  • Page 15: Introduction

    OM6040D Introduction Chapter Introduction ID: 1038-6516, Rev. 1.0 Page 1 - 1...
  • Page 16 Introduction OM6040D This page has been intentionally left blank. Page 1 - 2 ID: 1038-6516, Rev. 1.0...
  • Page 17: Overview

    • AMC module power switching as near as possible to backplane AMC connector • One four-tongue MCH slot • Pre-installed Kontron AM4910 MCH with 10 GbE Fabric interface • Integrated cooling fans The OM6040D supports up to four Double Full-size AMC Modules with various possible con- figurations of AMC CPUs and peripheral devices.
  • Page 18: Om6040D Shelf - Perspective View With Feet And Mounting Brackets

    Introduction OM6040D Figure 1-1: OM6040D Shelf - Perspective View with Feet and Mounting Brackets Power Supply Units (PSUs) Slots Slot Page 1 - 4 ID: 1038-6516, Rev. 1.0...
  • Page 19: Technical Specification

    OM6040D Introduction Technical Specification Table 1-1: OM6040D Shelf Specifications FEATURES SPECIFICATIONS Shelf MicroTCA™ cube form designed for Double Full-size AMC Modules Mechanical • Dimensions: 230.70mm x 217.70mm x 234.45mm (depth x width x height) (Without the mounting brackets being installed; with the mounting brackets in- stalled, the width is 258.12mm) •...
  • Page 20 Introduction OM6040D Table 1-1: OM6040D Shelf Specifications (Continued) FEATURES SPECIFICATIONS Power Supply Units ™ Up to two MicroTCA Double, Full-size pluggable AC power supply units: • Input voltage range: 90 to 264 VAC; 47 to 63 Hz • Input current maximum: 5A •...
  • Page 21: Standards

    OM6040D Introduction Standards This Kontron MicroTCA™ shelf complies with the requirements of the following standards. Table 1-2: Standards COMPLIANCE TYPE STANDARD TEST LEVEL / COMMENTS Emission EN55022 EN61000-6-3 Immission EN55024 EN61000-6-2 Electrical Safety EN60950-1 Conditions of acceptability: • The equipment has only been evaluated for use in office environment (pollution degree 2).
  • Page 22: Related Publications

    IPMI - Platform Management FRU Information Storage Definition, V1.0 Document Revision 1.1, September 27, 1999 PCI Express PCI Express Base Specification Revision 1.0a Serial ATA Serial ATA 2.5 Specification All Kontron Products Product Safety and Implementation Guide, ID 1021-9142 Page 1 - 8 ID: 1038-6516, Rev. 1.0...
  • Page 23: Component Description

    OM6040D Component Description Chapter Component Description ID: 1038-6516, Rev. 1.0 Page 2 - 1...
  • Page 24 Component Description OM6040D This page has been intentionally left blank. Page 2 - 2 ID: 1038-6516, Rev. 1.0...
  • Page 25: Shelf

    OM6040D Component Description Component Description Shelf The OM6040D shelf’s steel frame provides a robust housing for system components and air- flow channelization over the system slots. The OM6040D is delivered with four feet of which the front two are retractable for placement on a desktop or shelf. Mounting brackets are also provided for rack mounting.
  • Page 26: Om6040D Shelf - Front View

    Component Description OM6040D Figure 2-1: OM6040D Shelf - Front View ( 258.12 ) ( 240.62 ) PSU1 PSU2 Fan Bay Page 2 - 4 ID: 1038-6516, Rev. 1.0...
  • Page 27: Om6040D Shelf - Back View

    OM6040D Component Description Figure 2-2: OM6040D Shelf - Back View ID: 1038-6516, Rev. 1.0 Page 2 - 5...
  • Page 28: Om6040D Shelf - Bottom View

    Component Description OM6040D Figure 2-3: OM6040D Shelf - Bottom View front retractable feet Page 2 - 6 ID: 1038-6516, Rev. 1.0...
  • Page 29: Om6040D Shelf - Top View

    OM6040D Component Description Figure 2-4: OM6040D Shelf - Top View back ( 217.72 ) front ID: 1038-6516, Rev. 1.0 Page 2 - 7...
  • Page 30: Backplane

    Component Description OM6040D Figure 2-5: OM6040D Shelf - Left Side View - Cutaway Backplane AMC Module Bay Air Filter Page 2 - 8 ID: 1038-6516, Rev. 1.0...
  • Page 31: Backplane Front View

    OM6040D Component Description Backplane The OM6040D backplane provides the following basic functions: • Fabric interconnectivity for: • Gigabit Ethernet • 10GbE • PCIe or SRIO interfacing • SATA interfacing • Input power distribution and control for payload, management, and MCH (MCMC) power •...
  • Page 32: Mch

    If PCIe functionality is implemented, the root complex slots must be activated last. This can be changed by setting appropriate activation parameters in the MCH. The OM6040D is supplied with the Kontron AM4910 MCH installed at the factory. For further information about this MCH, refer to the AM4910 User Guide Page 2 - 10 ID: 1038-6516, Rev.
  • Page 33: Power Supply Unit

    OM6040D Component Description Power Supply Unit The Power Supply Unit has been specially designed for use with the OM6040D. It is a Double Full-size AMC form factor pluggable module with mounting screws to fix the PSU to the sub- rack. Input power is supplied via the front panel connector. Interfacing to the backplane is achieved via a very high power load Molex connector which interfaces power as well as monitor and control signals to the backplane.
  • Page 34: Fans

    Component Description OM6040D Fans The OM6040D’s thermal concept currently foresees the use of a four small fans. A single fan drawing and a drawing showing the fan tray with all fans is shown in figures below. Figure 2-9: Single Fan Page 2 - 12 ID: 1038-6516, Rev.
  • Page 35: Fan Tray With All Fans As Seen From Bottom

    OM6040D Component Description Figure 2-10: Fan Tray with all Fans as Seen from Bottom front rear ID: 1038-6516, Rev. 1.0 Page 2 - 13...
  • Page 36 Component Description OM6040D This page has been intentionally left blank. Page 2 - 14 ID: 1038-6516, Rev. 1.0...
  • Page 37: Installation

    OM6040D Installation Chapter Installation ID: 1038-6516, Rev. 1.0 Page 3 - 1...
  • Page 38 Installation OM6040D This page has been intentionally left blank. Page 3 - 2 ID: 1038-6516, Rev. 1.0...
  • Page 39: General

    Single, Full-size MCH in the lower slot area. Filler Panels Single Full-size filler panel installed in chassis slot 3 upper area Kontron AM4910 MCH module Single, Full-size MCH with extraction handle ID: 1038-6516, Rev. 1.0 Page 3 - 3...
  • Page 40: Safety

    Installation OM6040D Safety The following precautions must be observed: Caution, Electric Shock Hazard! The OM6040D requires AC mains power in the range from 90 to 264 volts for operation. Therefore, due caution must be exercised when handling or per- forming operations on the OM6040D when power is applied. Failure to comply with the above could endanger your life or health and may cause damage to the OM6040D or other system components including pro- cess-side signal conditioning equipment.
  • Page 41 Failure to comply with the above can result in improper operation or damage to the OM6040D or other components installed in the OM6040D. Kontron rejects any and all liability for improper operation or damage result- ing from inadequate cooling of the OM6040D or components installed in the OM6040D.
  • Page 42 Installation OM6040D Mounting The OM6040D is supplied with fixed mounting brackets for installation in a system cabinet. For cabinets which are wider than the OM6040D, additional mounting hardware is required which is not supplied with the OM6040D. For operation of the OM6040D on a flat surface, desktop or rack shelf, there are no special mounting fixtures except for the four feet.

Table of Contents