ferolli SKY F Series Instructions For Use, Installation And Maintenance

Table of Contents

Advertisement

Available languages

Available languages

Quick Links

SKY F
A
E
IT - ISTRUZIONI PER L'USO L'INSTALLAZIONE E LA MANUTENZIONE
EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE
B
=
50 50
Modello
A mm
E mm
11 F
295
210
335
250
14 F
375
290
17 F
200
C
D
=
B
C
D

Advertisement

Table of Contents
loading

Summary of Contents for ferolli SKY F Series

  • Page 1 SKY F 50 50 Modello A mm E mm 11 F 14 F 17 F IT - ISTRUZIONI PER L’USO L’INSTALLAZIONE E LA MANUTENZIONE EN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE...
  • Page 2: Avvertenze Generali

    SKY F 2.3 Accensione e spegnimento ATTENZIONE DURANTE IL FUNZIONAMENTO DELL’APPARECCHIO, LA TEMPERATURA AL MANTELLO POTREBBE RISULTARE ELEVATA. EVITARE IL CONTATTO PERCHÈ 1. AVVERTENZE GENERALI PUÒ SUSSITERE IL PERICOLO DI USTIONI. • Leggere ed osservare attentamente le avvertenze contenute in questo libretto di istruzioni. Collegamento alla rete elettrica •...
  • Page 3 SKY F 3.3 Collegamenti idraulici Collegamento con tubi coassiali Avvertenze Prima di effettuare l’allacciamento, verificare che l’apparecchio sia predisposto per il funzionamento con il tipo di combustibile disponibile ed effettuare una ac- curata pulizia di tutte le tubature dell’impianto. Effettuare gli allacciamenti ai corrispettivi attacchi secondo il disegno in copertina e ai simboli riportati sull’apparecchio.
  • Page 4: Servizio E Manutenzione

    SKY F Per il collegamento dei condotti separati montare sull'apparecchio il seguente accesso- 4. SERVIZIO E MANUTENZIONE rio di partenza: Tutte le operazioni di regolazione, messa in servizio e quelle di controllo periodico descritte di seguito, devono essere effettuate solo da Personale Qualificato e di sicura qualificazione (in possesso dei requisiti tecnici professionali previsti dalla normativa vigente).
  • Page 5 SKY F 4.4 Risoluzione dei problemi A - Presa di pressione a monte Diagnostica B - Presa di pressione a valle I - Connessione elettrica Valvola gas Lo scaldabagno è dotato di un avanzato sistema di autodiagnosi. Nel caso di un’anoma- R - Uscita gas lia all’apparecchio, il display lampeggia insieme al simbolo anomalia indicando il codice S - Entrata gas...
  • Page 6 SKY F 5. CARATTERISTICHE E DATI TECNICI 5.2 Schemi idraulici Tabella. 7 - Legenda figure cap. 5 5 Camera stagna 28 Collettore fumi 7 Entrata gas - Ø 1/2” 29 Collettore uscita fumi 8 Uscita acqua sanitaria - Ø 1/2” 38 Flussostato 9 Entrata acqua sanitaria - Ø...
  • Page 7 SKY F cod. 3540Z105 - Rev. 01 - 01/2018...
  • Page 8 SKY F 5.4 Schema elettrico ABM02 ° ° 230V 50 Hz fig. 15 - Circuito elettrico cod. 3540Z105 - Rev. 01 - 01/2018...
  • Page 9 C e r t i f i c a t o d i G a ra n z i a La presente garanzia convenzionale è valida per gli apparecchi È FERROLI S.p.A. - Via Ritonda 78/a - 37047 San Bonifacio (Verona) Italy - tel. +39.045.6139411 - fax. +39.045.6100933 - www.ferroli.com...
  • Page 10: General Instructions

    SKY F 2.3 Lighting and shutdown ATTENTION WHEN THE UNIT IS WORKING, THE CASING MAY BE VERY HOT. AVOID CON- TACT: RISK OF BURNS. 1. GENERAL INSTRUCTIONS Connection to the power supply • Carefully read the instructions contained in this instruction booklet. •...
  • Page 11 SKY F 3.3 Plumbing connections Connection with coaxial pipes Important Before making the connection, check that the unit is arranged for operation with the type of fuel available and carefully clean all the system pipes. Carry out the relevant connections according to the cover diagram and the symbols giv- en on the unit .
  • Page 12: Service And Maintenance

    SKY F For the connection of separate ducts, fit the unit with the following starting accessory: 4. SERVICE AND MAINTENANCE All adjustment, commissioning and periodic checking operations described below must only be carried out by Qualified Personnel (meeting the professional technical require- ments prescribed by the current regulations).
  • Page 13: Troubleshooting Diagnostics

    SKY F 4.4 Troubleshooting A - Upstream pressure point Diagnostics B - Downstream pressure point The water heater has an advanced self-diagnosis system. In case of a fault in the unit, I - Gas valve electrical connection the display will flash together with the fault symbol indicating the fault code. R - Gas outlet S - Gas inlet There are faults that cause permanent shutdown (marked with the letter "A"): to restore...
  • Page 14: Technical Data And Characteristics

    SKY F 5. TECHNICAL DATA AND CHARACTERISTICS 5.2 Plumbing diagrams Table. 7- Legend - figures cap. 5 5 Sealed chamber 28 Fume manifold 7 Gas inlet - Ø 1/2” 29 Fume outlet manifold 8 DHW outlet - Ø 1/2” 38 Flow switch 9 DHW inlet - Ø...
  • Page 15 SKY F cod. 3540Z105 - Rev. 01 - 01/2018...
  • Page 16 SKY F 5.4 Wiring diagram ABM02 ° ° 230V 50 Hz fig. 15 - Electrical circuit cod. 3540Z105 - Rev. 01 - 01/2018...