INDO SiCURA Installation Instructions Manual

Advertisement

Quick Links

fresh thinking
trusted technology
INDO SiCURA
Installation Instructions
+44(0) 203 051 1687 | info@indolighting.com

Advertisement

loading

Summary of Contents for INDO SiCURA

  • Page 1 INDO SiCURA Installation Instructions +44(0) 203 051 1687 | info@indolighting.com...
  • Page 2 Any debris on the and with care top surface of the fitting should be washed out. • INDO Lighting will not be held liable for any accident, injury or damage caused Please keep this document for future reference or bookmark the link below: Installation Recommendation: www.indolighting.com/installation...
  • Page 3 Post Top Installation Open unit with a 5mm Allen key / hex bit and undo the self-retaining bolts. Stay must fall into the recess to lock the lid in the open position. SHIM SHIM BLOCK The product is supplied with a default post top and Refer to the inclination sections below.
  • Page 4 To adjust the post top inclination for +5° & +10° Remove and retain the long bolt. Remove the s Flip the shim block over to observe the inclination him block. angle shown here for PT. Post Top 5° inclination: Flip shim block over to show 5° and secure back in place with the bolt. Post Top 10°...
  • Page 5 Wiring CRUSH RISK Caution: Ensure the cable is routed through the centre Refer to the wiring diagram to suit the scoop and is not caught or crushed against the column. installation requirements. Feed cable through cable gland and tighten. Close unit To close unit, lift the lid slightly and flip the stay Incorrect stay position will cause damage to the so it drops into the recess.
  • Page 6 Side Entry Installation Remove grub screws. Fit grub screws. Mount product on to bracket. Change door to the horizontal position. Tighten grub screws to 8-10 Nm. Open unit with a 5mm allen key Stay should fall into the recess to lock the lid in the open position. / hex bit and undo the self- retaining bolts.
  • Page 7 To adjust the side entry inclination for -5° & -10° Remove and retain the short bolt. Flip the shim block over to observe the inclination Remove the shim. angle - shown here for SE. Side Entry -5° inclination: Flip shim block over to show SE-5°...
  • Page 8 Mount product on to bracket Mount Product on to bracket. Tighten Grub screws to 8-10 Nm. Wiring Feed cable through cable gland and tighten. Refer to the wiring diagram to suit the installation requirements. Close unit To close unit, lift the lid slightly Incorrect stay position will cause Close unit with a torque wrench to flip the stay so it drops into...