HUMIDITY AND AMBIENT PRESSURE METER WITH HUMIDITY PROBE KC-326B
Introduction:
The KC-326B Humidity and Environmental Pressure Meter incorporates several energy
saving sensors in a compact design. It measures in real time the ambient temperature,
humidity, atmospheric pressure, moisture content of a piece of wood and can quickly
calculate the dew temperature, absolute humidity (g/kg and grains/pounds), wet bulb
temperature, and steam pressure with the dew-surface temperature calculation mode, 20
data retention groups in memory and 8000 groups of automatic data recording. The device
has a large screen with two LCDs with intelligent management. It is an ideal instrument for
monitoring food, medical supplies, warehouse and home decoration..
Safety instrucctions
Failure to follow the instructions below may result in electric shock or personal injury.
- Please read this manual carefully before using this product.
- Do not remove any labels from this product.
- Do not use the product in the presence of explosive or flammable gases.
- Please take care with the probe and do not damage it. When you have finished using it, put on the protective
cap.
- The probe is sharp. Be careful when using it.
- Keep the product out of the reach of children..
Battery Safety Instructions
- Please remove the batteries when cleaning this product.
- Remove the batteries before storing the device for a long period of time.
- Please insert the batteries correctly as the negative and positive pole instructions indicate.
- Please dispose of the batteries correctly. High temperatures can cause explosions.
- Place insulating tape around the battery to avoid contact with other objects..
Product details
KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER
HT 6550200200
Page - 1

Advertisement

loading
Need help?

Need help?

Do you have a question about the KC-326B and is the answer not in the manual?

Questions and answers

Summary of Contents for MEI KC-326B

  • Page 1 HUMIDITY AND AMBIENT PRESSURE METER WITH HUMIDITY PROBE KC-326B Introduction: The KC-326B Humidity and Environmental Pressure Meter incorporates several energy saving sensors in a compact design. It measures in real time the ambient temperature, humidity, atmospheric pressure, moisture content of a piece of wood and can quickly...
  • Page 2 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 2 A- Sensor Protective Cap B- Buckle C- Thermocouple interface (optional accessory, not included in the product) D- LCD screen E- LOG/SET button. Starts and stops data recording. F- MAX/MIN button. Change measurement mode to MAX/MIN. Alarm setting with UNIT button.
  • Page 3 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 3 USB connection indicator Low battery symbol PROBE - Thermocouple indicator DEW - Dew point temperature WBT - Wet Bulb Temperature Indicator DATA, TIME - Time and date indicator APO - Auto Power Off Indicator...
  • Page 4 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 4 ◦ ◦ Press the UNIT/ button to change ºC/ºF, simultaneously switch between g/m3 and mg/L in AH mode. ◦ ◦ Press the STORE/ENTER/ button for 2 seconds to record the data displayed on the screen. The memory serial number will automatically increase by 1.
  • Page 5 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 5 ◦ ◦ Press the STORE/ENTER/ button for 2 seconds to record the data displayed on the screen. The memory serial number will automatically increase by 1. • - MR Mode (Mixing Ratio) ◦...
  • Page 6 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 6 ◦ - MI mode (humidity without external probe) ◦ ◦ Under this mode, if nothing is touched and any value other than "0" is displayed, it needs to be calibrated.
  • Page 7 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 7 ◦ Press the MAX/MIN button to measure the maximum and minimum values of the readings. (This function is disabled under the MI and ME modes. Under CON mode, the first row shows the actual value and the second row shows the maximum and minimum value of the thermocouple.)
  • Page 8 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 8 ◦ ◦ Press the STORE/ENTER/ button to save the alarm limit and auto exit and return to normal mode. Note: The upper alarm value must be larger than the lower alarm value. If not, a beep will sound in the device warning you to reset the alarm limits.
  • Page 9 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 9 ◦ ◦ The "DATA" symbol shows year/month/day and the "TIME" symbol shows hour/minute. Press the UNIT/ or STORE/ENTER/ button to change "DATA"/"TIME". ◦ Push the button /HOLD for go out of this mode.
  • Page 10 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 10 ◦ - Auto Erase Recording Data ◦ ◦ Enter revision and adjustment mode by moving the arrow pointing to "CLR". ◦ Press the ZERO/WBT button for 2 seconds, and "CLR" will appear on the screen. All recording data will be erased and the serial number will return to 01.
  • Page 11 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 11 ◦ If you use only the battery, the recorded data will be saved before the low battery symbol appears. After the low battery symbol appears, the recording will stop and save the previous data. If the device has the low battery symbol activated, you cannot save any data.
  • Page 12 HT 6550200200 KC-326B HUMIDITY AND ENVIRONMENTAL PRESSURE METER Page - 12 Technical Specifications Product name Humidity and environmental pressure meter with humidity probe for walls and wood. Model KC-326B Humidity range of the probe 0~99.9% Humidity range of the sensor 0~99.9%...