TopMaster Air Handling Unit
Control and Regulation Equipment

Advertisement

Table of Contents
loading

Summary of Contents for flakt woods TopMaster

  • Page 1 TopMaster Air Handling Unit Control and Regulation Equipment...
  • Page 2: Table Of Contents

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Contents Electrical connection Electrical cabinet ............3 Electrical connection and fuse protection ....3 Sensors and accessories Sensors and accessories ..........4 Temperature sensor ........... 5 Damper actuator ............5 Water heater ..............6 Liquid cooling ............
  • Page 3: Electrical Connection

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Electrical cabinet – Electrical connection and fuse protection Electrical connection and fuse protection Electrical cabinet Electrical connection is made to the terminals in the ec- trical cabinet. A separate switch -disconnector must be used, e.
  • Page 4: Sensors And Accessories

    CONTROL AND REGULATION EQUIPMENT Sensors and accessories Sensors and accessories All sensors and accessories are connected to TopMaster via connections in the electrical cabinet. Cables to exter- nal components are secured in the electrical cabinet using the tie-rail with a cable tie, for example.. The cable is then placed against the cellular plastic strip on the unit (see figure 1).
  • Page 5: Temperature Sensor

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Sensors and accessories Temperature sensors Filter monitors (accessories) The TopMaster is equipped as standard with three factory- The filter monitors GP1 and GP2 are enclosed separately. mounted temperature sensors: Connect hose to test point. Set the required alarm limit across the filter using the knob on the sensor. For installa- tion, see enclosed instruction.
  • Page 6: Water Heater

    2 A Potential-free connection, max. load 24 V, 200 mA. TopMaster has a total alarm output which can be selec- Liquid cooling ted, allowing you to indicate just A alarms or both A and Circulation pump (CP2) and valve actuators (SV2) for B alarms.
  • Page 7: Valve For Heating And Cooling

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Sensors and accessories Valve actuator for heating SV1 and 3-way valve VXG cooling SV2 The bypass is closed by turning the spindle inwards, the bypass is opened by turning the spindle outwards.
  • Page 8: Connection Of External Components

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Sensors and accessories Connection of external components 3 4 5 6 7 8 9 1. CP1/SK1 Start 2. CP2/DX Start 3. CO 2 4. ST1 5. ALM, Alarm output, max 24 V, 200 mA 6.
  • Page 9: Installation And Connection

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Installation and connection 1. Open the control panel using a screwdriver 5. Connect the cable to the back of the display as shown above. Note. Please do not touch the electronics. Note! The control panel is only for indoor use. 2. Lift the display out of the enclosure.
  • Page 10: General, General Buttons And Symbols

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT General, general buttons and symbols General General buttons and symbols This section of the instructions provides an introduc- The following buttons and symbols are universal and tion on how the Curo™ touch control panel works and available on many menu pages.
  • Page 11: Home Screen

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Home screen overview Status line Heat recovery active Post-heater active Defrosting in progress Clock Current set point value Cooling active 18°C 11:08 Operating status Alarm Manual mode No alarm Automatic mode Alarm B...
  • Page 12: Basic Operation, Overview

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Operation, home screen and submenus Shortcut to set the Shortcut to set the temperature set point time and date Setpoint Temp Set Time Setpoint Temp. 18°C 11:08 Alarm See page 13. Select operating mode See page 13.
  • Page 13: Submenus

    Fan speeds and possible pressures and flow No Alarm rates only for reading. Air quality Alarm B Not in use for TopMaster. Alarm A System overview Summarizes the unit’s main operating para- meters. See section “Parameter list” on pages Press the icon to enter the Alarm screen.
  • Page 14: Settings

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Configuring time, date and language Settings Time/Date To enter the settings menu: Set Time 2:01 21 C 1. Set the time and press the Confirm button 1. Press the gear cog button. Set Date 2. Press the spanner button.
  • Page 15: Login

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Advanced settings Login Settings for installer and service personnel To enter the “Settings” menu for installers and service personnel requires login. Settings The default passcode is 0000. This can be changed later.
  • Page 16: Commissioning Wizard

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Commissioning Wizard Commissioning Wizard The Commissioning Wizard allows the fan settings to be configured in a simple and intuitive manner. The Commissioning Wizard is accessed by selecting the “Run Commissioning Wizard” option from the Set- tings screen. Home Settings 1.
  • Page 17: Schedules

    TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Schedules Schedules Schedule The controller has three types of internal time schedules: Weekly, Single date and Date period. 16. Date period 4 First, program the weekly schedule with the required times. Then use any single date programs and the period to enter exceptions, such as weekends and holidays. Each schedule also needs to be activated. This is done by pressing the grey tick button. A green tick indicates that the...
  • Page 18 TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Schedules (cont.) Example 2 Example 3 Below is an example of a weekly schedule configured to Below is an example of a weekly schedule configured to run the fans at normal speed from 08.00 to 18.00 Monday run the fans at normal speed from 08.00 to 18.00 Monday to Thursday, from 08.00 to 17.00 on Friday and 10.00 to to Friday. At all other times, the fans are configured to...
  • Page 19 TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Schedules (cont.) Single date schedule (1–4) A single date schedule is defined as a one-off schedule that automati c ally starts and finishes on the same date. Note! Example Remember to enable the desired time The unit must be switched off on 6 June. channels by pressing 1. Single date 1 Stop Fan speed Temp Setpoint 0°C...
  • Page 20: Control And Regulation Functions Control And Regulation Functions

    100%. This means that the new calculated setpoint for the 2. Temperature controls supply air controller is: TopMaster has three temperature control options, supply Calculated setpoint = setpoint + (setpoint – exhaust air air, extract air control and room control. temperature) x cascade A = 18 + (18-16) x 0.5 = 19 ° C. Fläkt Woods 8217 GB 2014.07.02...
  • Page 21 TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Control functions (cont.) Room control Setpoint Room control gives the best control of temperature in a Outdoor temperature compensation specific room and is used when only one unit serves this room. This method works best for larger premises. By replacing the exhaust temperature sensor with a room temperature sensor placed in the room in question, a good room temperature value is achieved.
  • Page 22 TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Control functions (cont.) Pressure control regulates air pressure in index duct (duct 5. Cooling recovery with a maximum pressure drop, and where the static pres- Cooling energy recovery is used when cooling load is sure is lowest). The pressure sensor (GP3) is placed at the...
  • Page 23: Parameter List

    Fan status Supply air fan, speed 0 or 30–100 Extract air fan, speed 0 or 30–100 Air qual ity No such function in TopMaster. Overview This menu is used for maintenance and troubleshooting. Software version, Control panel Speed, Supply air fan 0 or 30–100...
  • Page 24 Extract air flow, normal speed 0–9999 Extract air flow, high speed 0–9999 5. Heating / Cooling 5.1 Pre-heater No such function in TopMaster. 5.2 Heating / Cooling See also pages 20–22. Control mode 1 = Standard, supply air control 2 = Cascade control.
  • Page 25 S / W = heat pump runs in winter, heating/cooling cooling pump runs in the summer. Anti-jamming of pumps takes place 12.00 to 12.05 every day. 6. Air quality No such function in TopMaster. 7. Alarm handling 7.1 Alarm Filter alarm time 0–600 days 0 = Disabled.
  • Page 26 TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Parameter list (cont.) Parameter Type of value Range Unit Default value Comments Sensor fault Cold corner Not used in TopMaster. Sensor fault UI1 Not used in TopMaster. Sensor fault UI2 Not used in TopMaster.
  • Page 27 TopMaster Air Handling unit CONTROL AND REGULATION EQUIPMENT Parameter list (cont.) Parameter Type of value Range Unit Default value Comments 8. Configuration 8.1 IP address Static = IP address is manually set. Static/Dynamic Static/Dynamic Dynamic Dynamic = IP-address is automa- tically set via DHCP .
  • Page 28 We Bring Air to Life Fläkt Woods is a global leader in air management. We specialize in the design and manufacture of a wide range of air climate and air movement solutions. Our collective experience is unrivalled. We are constantly aiming to provide systems that precisely deliver the required features and performance as well as maximum energy efficiency.