Hartridge IFT-c Operating And Servicing Manual

Hartridge IFT-c Operating And Servicing Manual

Injector function tester controller

Advertisement

World Leaders in Diesel Fuel Injection Test Equipment.
IFT-c
Injector Function Tester Controller
Operating and Servicing Manual
HL048 (EN) Issue 4, H1852, August 2011
THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016
Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IFT-c and is the answer not in the manual?

Questions and answers

Summary of Contents for Hartridge IFT-c

  • Page 1 Injector Function Tester Controller Operating and Servicing Manual HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 2 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 3 HARTRIDGE LIMITED IFT-c Operating and Servicing Manual Hartridge IFT-c HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 4 IFT-c Operating and Servicing Manual HARTRIDGE LIMITED This page intentionally left blank HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 5: Table Of Contents

    8. TROUBLESHOOTING ..........................12 9. WIRING DIAGRAM ............................13 HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 6: This Is An Uncontrolled Document Downloaded By Lukas Matuska On 16 Feb

    IFT-c Operating and Servicing Manual HARTRIDGE LIMITED This page intentionally left blank HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 7: Foreword

    Foreword Copyright Hartridge™ Ltd. reserves the copyright of all information and illustrations in this publication which is supplied in confidence and which may not be used for any other purpose other than that for which it was originally supplied. The publication may not be reproduced in part or in whole without the consent in writing of this company.
  • Page 8: Any Technical Intervention Requires Certified Hartridge Training. Contact Hartridge Ltd For Details

    Use an appropriate barrier supplied. cream. HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 9: Introduction

    IFT-70N it gives the ability to measure nozzle opening pressures on traditional single stage injectors. The IFT-c is of a steel fabricated construction with a 2 line LCD display of 20 characters. It has a green start button, red escape button, a rotary control and 7 individual injector driver leads.
  • Page 10: Ift-C Overview

    Overload protection Electrical inlet Injector driver loom outlets HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 11: Installation

    3. Installation Note: When installing an IFT-c to an IFT-70 follow the instructions as detailed in Hartridge manual HL047. This section should only be followed if the IFT-c is being used in conjunction with a HH700 / 701. 1. Unpack the IFT-c.
  • Page 12: Any Technical Intervention Requires Certified Hartridge Training. Contact Hartridge Ltd For Details

    ‘o’ – light off ‘*’ – light on HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 13: Operation - Driving An Injector

    IFT-c does not interrogate the injector on these test plans. 6. Nozzle Opening Pressure detection (IFT-70n only) When the unit is connected to an IFT-70n the IFT-c gives capability to measure NOP on mechanical injectors. In this instance testplan 51 is enabled and the display will be as follows: ↑...
  • Page 14: Operating Notes

    If the injector will not fire, check that the overload button on the rear panel is pushed in. HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 15: Wiring Diagram

    IFT-c Operating and Servicing Manual 9. Wiring diagram HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 16: Any Technical Intervention Requires Certified Hartridge Training. Contact Hartridge Ltd For Details

    IFT-c Operating and Servicing Manual HARTRIDGE LIMITED HL048 (EN) Issue 4, H1852, August 2011 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 17: Any Technical Intervention Requires Certified Hartridge Training. Contact Hartridge Ltd For Details

    This page intentionally left blank THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 18: Any Technical Intervention Requires Certified Hartridge Training. Contact Hartridge Ltd For Details

    THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.
  • Page 19: Any Technical Intervention Requires Certified Hartridge Training. Contact Hartridge Ltd For Details

    Tel: +44 (0)1280 825 600 Fax: + 44 (0)1280 825 601 Email: support@hartridge.com www.hartridge.com © Hartridge Ltd., 2009 THIS IS AN UNCONTROLLED DOCUMENT downloaded by Lukas Matuska on 16 Feb 2016 Any technical intervention requires certified Hartridge training. Contact Hartridge Ltd for details.

Table of Contents

Save PDF