Taco Electronic Solutions iWorx CSM1 Installation Manual

Chilled beam sensor module, self-contained interoperable controller model ucp-1 for software version 1

Advertisement

Quick Links

Self-Contained Interoperable Controller Model UCP-1 for Software Version 1
SUPERSEDES: New
Plant ID: 001-4127
CSM1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Purpose of This Guide . . . . . . . . . . . . . . . . . . . . . . . . . 2
Applicable Documentation . . . . . . . . . . . . . . . . . . . . . . 3
Typical Use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Representations and Warranties . . . . . . . . . . . . . . . . . 3
Installation Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Static Electricity . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
FCC Compliance . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Before Installing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
About this Document . . . . . . . . . . . . . . . . . . . . . . . . 5
Inspecting the Equipment . . . . . . . . . . . . . . . . . . . . 5
Equipment Location . . . . . . . . . . . . . . . . . . . . . . . . . 5
Selecting a Power Source . . . . . . . . . . . . . . . . . . . . 5
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Mounting the Device . . . . . . . . . . . . . . . . . . . . . . . . 6
Routing Cabling to the Device . . . . . . . . . . . . . . . . . 6
Grounding the Device . . . . . . . . . . . . . . . . . . . . . . . 7
© 2013 Taco Electronic Solutions, Inc.
Installation Guide
CSM1 Chilled Beam Sensor Module

Table of Contents

Wiring Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Connecting Input Devices . . . . . . . . . . . . . . . . . . . . 8
Other Connections. . . . . . . . . . . . . . . . . . . . . . . . . . 8
Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Electrical Inputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Recommended Sensor Wire . . . . . . . . . . . . . . . . . . 9
Power. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Mechanical. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Diagnostic LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Troubleshooting Tips . . . . . . . . . . . . . . . . . . . . . . . 11
502-045
EFFECTIVE: July 25, 2013
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the iWorx CSM1 and is the answer not in the manual?

Questions and answers

Summary of Contents for Taco Electronic Solutions iWorx CSM1

  • Page 1: Table Of Contents

    Routing Cabling to the Device ....6 Grounding the Device ..... . . 7 © 2013 Taco Electronic Solutions, Inc.
  • Page 2: Csm1

    • Users who engineer control logic • Users who set up hardware configuration • Users who change hardware or control logic • Technicians and field engineers of Taco Electronic Solutions, Inc. 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 3: Applicable Documentation

    REPRESENTATIONS AND WARRANTIES This Document is subject to change from time to time at the sole discretion of Taco Electronic Solutions, Inc. All updates to the Document are available at www.taco-hvac.com. When installing this product, it is the reader’s responsi- bility to ensure that the latest version of the Document is being used.
  • Page 4: Installation Guide

    Taco Electronic Solutions, Inc. will not be responsible for any product or part not installed or operated in conformity with the Document and instructions or which has been subject to accident, disaster, neglect, misuse, misapplication, inade- quate operating environment, repair, attempted repair, modification or alteration, or other abuse.
  • Page 5: Before Installing

    INSTALLATION Warning: Electrical shock hazard. To prevent electrical shock or equipment damage, disconnect ALL power sources to controllers before installing or servicing this equipment or modifying any wiring. 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 6: Mounting The Device

    Routing Cabling to the Device Cabling used to connect the power source and cabling used to connect the FTT-10A network must remain separated within the control enclosure and wiring conduit. 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 7: Grounding The Device

    WARNING: Terminals 4,6,9,12,15,18 and 38 are connected internally on all CSM1 controllers. Disconnect ALL power sources when installing or servicing this equipment to prevent electrical shock or equipment damage. Figure 2: CSM1 Terminal Connections 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 8: Connecting Input Devices

    Network wiring must be twisted pair. One network wire must be connected to terminal NETA (T1) and the other network wire must be connected to terminal NETB (T2). Polarity is not an issue since an FTT-10A network is used for commu- nications. 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 9: Specifications

    Dimensions: 5.55” (141mm) high, 6.54” (166 mm) wide, 1.75” deep (44 mm), ABS Controller Weight: 0.70 pounds (0.32 kilograms) Shipping Weight: 1.0 pounds (0.46 kilograms) Processor: 3150 Neuron 10 MHz Flash: 48 Kilobytes 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 10: Troubleshooting

    – Green when there is network activity – Off when there is no network activity Service – Illuminated when the service pin is depressed or when a controller gets configured by the LCI. 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 11: Troubleshooting Tips

    1.Make sure controllers, sensors, and power supplies are connected and communicating to desired devices. 2.Record precise hardware setup indicating the following: Version numbers of application software. Device and/or firmware version number. A complete description of difficulties encountered. 502-045, Effective: July 25, 2013 © 2013 Taco Electronic Solutions, Inc.
  • Page 12 Taco Electronic Solutions, Inc. is a subsidiary of Taco, Inc. Visit our web site at: http://www.taco-hvac.com Printed in the USA iWorx® and iView® are registered trademarks of Taco Electronic Solutions, Inc. © 2013 Taco Electronic Solutions, Inc. LON, LONWORKS, & LONMARK are trademarks of Echelon Corporation...

Table of Contents