2. SPECIFICATIONS
These propane heaters are fan assisted and fitted with a piezoelectric ignition system for trouble-free starting and feature a direct gas head
assembly. Features a safety solenoid preventing the unit from leaking gas without first being electrically started. Front foot offers height adjustment.
All models are tested and certified to CE/EN standards by the DVGW test house. Supplied with an approved propane gas regulator and hose.
All regulators are Calor approved.
Model No: . . . . . . . . . . . . . . . . . . . . . LP40, LP40S . . . . . . . . . . . LP50, LP50S . . . . . . .LP100.V3, LP100S . . . . . . . . . LP150, LP150S
Output:. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12.3kW . . . . . . . . . . . . . 8.2-16.1kW . . . . . . . . . . . . 19.8-28.4kW . . . . . . . . . . . . 35.2-43.9kW
Output:. . . . . . . . . . . . . . . . . . . . . . . . . 42,000Btu/hr . . . . . . 28,000-55,000Btu/hr . . . . . . 68,000-97,000Btu/hr . . . . 120,000-150,000Btu/hr
Airflow: . . . . . . . . . . . . . . . . . . . . . . . . . . . . 300cfm . . . . . . . . . . . . . . . . 300cfm . . . . . . . . . . . . . . . . 400cfm . . . . . . . . . . . . . . . . 600cfm
Fuel Consumption:. . . . . . . . . . . . . . . . . .0.88kg/hr . . . . . . . . . . .0.58-1.15kg/hr . . . . . . . . . . . .1.47-2.1kg/hr . . . . . . . . . . . . . . 2.5-3kg/hr
Electrical Input: . . . . . . . . . . . . . . . . . . . . . . . 230V . . . . . . . . . . . . . . . . . . 230V . . . . . . . . . . . . . . . . . . 230V . . . . . . . . . . . . . . . . . . 230V
Length x Width x Height:. . . . 460 x 196 x 325mm . . . . . . 460 x 196 x 325mm . . . . . . 638 x 230 x 395mm . . . . . . 638 x 230 x 395mm
Fuel: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Propane . . . . . . . . . . . . . . . .Propane . . . . . . . . . . . . . . . Propane . . . . . . . . . . . . . . . Propane
Heated Volume:. . . . . . . . . . . . . . . . . . . . . 37,080ft
Heated Volume:. . . . . . . . . . . . . . . . . . . . 1,050mtr
3.
INSTALLATION
Note: If a small gas cylinder is used, the heater may not operate at maximum efficiency. It is recommended to use two or more cylinders
linked in parallel, to achieve maximum continuous efficiency (fig.1).
3.1.
Connections
3.1.1. Check heater and gas cylinder to ensure that they are both in good condition. If not, stop and contact your supplier immediately.
3.1.2. Site the heater and gas cylinder in the location to be heated.
3.1.3. Connect the heater to an electrical supply outlet, ensuring that the machine is correctly earthed. See safety instructions.
3.1.4. Connect the gas supply hose to the pressure regulator, and connect the regulator to the gas cylinder (fig.3). Note: Left hand threads.
Connect the other end of the gas supply hose to the heater's gas inlet connector (fig.4). Ensure all connections are tight.
3.1.5. Gradually open the tap of the gas cylinder. Check hose and all fittings for gas leaks. Close gas tap if gas is present
WARNING! DO NOT USE A NAKED FLAME! To check for leaks, we recommend the use of a foamy soap solution.
fig.3
4.
OPERATION
IMPORTANT: To ensure continuous ventilation to the heater area, a ventilation opening must connect to the outside of the premises where the heater is to
operate. The opening must be 100cm
4.1.
Switching Heater On
4.1.1. Turn the On/Off switch to the 'ON' position.
4.1.2. Push in and turn the gas control knob (fig.2) counterclockwise to LOW/
light the burner, if it doesn't repeat once or twice until it lights, then hold the gas control knob in for a further 30 seconds before releasing.
4.1.3. If burner stops when the gas control knob is released, leave the fan on, but wait for one minute before repeating the ignition
sequence, again holding the gas control knob in for 30 seconds before releasing.
4.1.4. When the burner is lit, push in and turn the gas control knob counterclockwise to the desired setting (1/2/3), (for all models, except LP40
and LP40S which only have one setting).
4.2.
Switching Heater Off
4.2.1. Turn the gas control knob (fig.2) fully clockwise to the O position. Allow the fan to continue running until the flame has shut down, then
turn the On/Off switch to the 'OFF' position. Shut off the gas cylinder tap. Isolate the heater from the electrical supply.
4.2.2. When the heater is not in use for any length of time, disconnect it from the electrical and gas supply and store it in a safe, dry, childproof
location.
 WARNING! If the flame shuts down during operation, before repeating the ignition sequence, make sure that the fan is not jammed, and the air
inlet and outlet are completely free of obstructions. If it is due to overheating, the cause of the problem must be determined and corrected before
repeating the ignition procedure.
© Jack Sealey Limited
3
. . . . . . . . . . . . . . . 48,558ft
3
. . . . . . . . . . . . . . 1,375mtr
fig.1
2
for every kW, and must be set at an equal distance from the upper and lower parts of heater operating area.
Original Language Version
3
. . . . . . . . . . . . . . . 88,287ft
3
3
. . . . . . . . . . . . . . 2,500mtr
3
*
*
position, (HIGH/
on Models LP40 and LP40S). This will
LP 40, 40S, 50, 50S, 100.V3, 100S, 150, 150S
. . . . . . . . . . . . . . 132,430ft
3
. . . . . . . . . . . . . . 3,750mtr
3
fig.2
fig.4
Issue No:3(I) - 11/09/13