Download Print this page

Indal LIBRA Series Installation Instructions

Advertisement

Quick Links

Louvers table
G1
0
5 10
PLL 18
-
-
-
PLL 24/36
-
-
-
PLL 40/55/80
-
-
-
G2
0
5 10
PLL 18
-
-
5
PLL 24
-
-
5
PLL 36
-
-
4
PLL 40/55/80
-
-
6
G3
0
5 10
PLL 18
-
-
4&6
PLL 24
-
-
4&6
PLL 36
-
-
3&6
PLL 40/55/80
4&8
-
-
Operation instructions for Indal light fitting type Libra 65 and 70
Please read the instructions carefully before starting any works!
Content:
1. Safety instructions
2. Conformity with standards
3. Technical data
4. Installation & installation instructions
5. Taking into operation
6. Maintenance
1. Safety instructions
For skilled electricians and trained personnel in accordance with national legislation,
including the relevant standards.
Observe the national safety rules and regulations for prevention of accidents and the following
safety instructions:
·
The technical data indicated on the lighting fitting and the gear are to be observed.
·
Changes to the design and modification to the light fitting are not permitted.
·
The light fitting shall be operated as intended and in undamaged and perfect condition.
·
Repairs may only be carried out by a qualified "electrician".
·
Do not keep these operation instructions inside the fitting during operation.
2. Conformity with standards
·
This lighting fitting meets requirements of EN 60 598.
·
It has been designed, manufactured and tested as a state of art product and according
to EN ISO 9001-2000 quality management system.
·
It has been ENEC tested, certificate KEMA 2096704.01.
·
It meets CE requirements.
3. Technical data
Technical details are stated on the product label. This label states lamp type, lamp wattage,
supply voltage and frequency, power factor/cos phi, nominal current, electrical insulation
class (if class 2, double insulated), maximum ambient temperature (if nothing stated the
maximum ambient temperature is 25°C), IP value, CE mark and ENEC mark (if applicable
for this version).
·
Ingress Protection: IP 65 complete (standard). Option of IP 66 available.
·
Supply terminal: Terminal block (standard). Option of plug-socket or circuit breaker
available.
·
Storage temperature in original packaging: -40°C to +60°C.
·
Cable gland: 1 x M20, for round cables of 7-14mm in diameter.
·
Mounting fixation Libra 2565/2567 and 2570/2572: 2 x M10, 20Nm.
·
Mounting fixation Libra 2566 and 2571: 1 x M10, 20 Nm.
1
2
1. Installation
·
Observe the respective national regulations as well as the general rules of engineering
which apply to the installation and operation of electrical apparatus. Transport and
storage of the luminaire is permitted in original packaging and specified position only.
·
Installation instructions are included in the packaging of each luminaire.
·
Only use such lamps that have been certified for these light fittings. See type label on
the packaging or in the luminaire for the intended type.
2. Taking into operation
Prior to operation, check the light fitting for its proper functioning and installation in
compliance with these operation instructions, the installation instructions and other applicable
regulations.
3. Maintenance (every 4 years or at lamp change; whatever is the shortest period)
The manufacturer guarantee is subject to the effective and scheduled fulfilment of the
mentioned regular maintenance tasks, by specifically skilled and authorised workers, as well
as to the information (regular shipment of maintenance or repair reports), and also to the lack
of changes in the luminaires working condition (vibration levels, traffic, environment, etc.).
Observe the national regulations applicable to the maintenance, servicing and testing of
electrical apparatus as well as the general rules of engineering.
Servicing:
When servicing, in particular those components that affect the type of protection, will have to
be checked and replaced if applicable, e.g.;
·
Housing and bowl for any cracks or damages e.g. in paint finish.
·
Gaskets for their perfect condition. Grease the gasket with acid-free grease.
·
Terminals for their firm fit.
·
In case of IP 66 rating, cleaning of the interior of the luminaire should not be
necessary.
·
Because of risk of electrostatic charge, the light fitting shall only be cleaned with a
damp cloth or sponge. Only use customary household wash-up liquid diluted in water
as specified. The water temperature may be hand warm. After cleaning, rinse with
clear water.
·
Lamp replacement: keep replacement intervals as specified by the lamp manufacturer.
Repair:
Prior to replacing or removing any components or lamps, observe the following:
·
Even though this lighting fitting may (optionally) be equipped with a circuit breaker,
we advice to disconnect the lantern from the power supply before opening or carrying
out repairs!
·
Only use genuine Indal spare parts.
Data subject to change. Rev. Date: 18/02/2010
MONTAGE VOORSCHRIFT
INSTALLATION INSTRUCTIONS
2565/2566/2567/2570/2571/2572
MONTAGEANWEISUNG
2570
2571
2572
2565
2566
2567
W
Kg
m
2
Cx s
Max
FSD 18
19
5.5-5.8
0.10
0.083
-20 C
FSD 24
27
5.5-5.8
0.10
0.083
-20 C
FSD 36
39
5.5-5.8
0.10
0.083
-20 C
FSD 40
45
6.6-7.0
0.13
0.095
-20 C
FSD 55
62
6.6-7.0
0.13
0.095
-20 C
FSD 80
86
6.6-7.0
0.13
0.095
-20 C
LIBRA
INSTRUCCIONES DE MONTAJE
INSTRUCTION D' INSTALLATION
INSTRUÇ ES DE MONTAGEM
922
213
922
213
922
213
773
213
773
213
773
213
Min
Max
Nr..
T20
40 C
2565/66
40 C
2565/66
5mm
40 C
2565/66
40 C
2570/71
40 C
2570/71
4mm
40 C
2570/71
IK
08
P1
IP
65
IP
05
66

Advertisement

loading

Summary of Contents for Indal LIBRA Series

  • Page 1 3&6 PLL 40/55/80 4&8 2571 Operation instructions for Indal light fitting type Libra 65 and 70 1. Installation Please read the instructions carefully before starting any works! · Observe the respective national regulations as well as the general rules of engineering Content: which apply to the installation and operation of electrical apparatus.
  • Page 2 ∅ 60 (48/42/34/32) O 6-12mm O 2.5mm max L=150 ∅ 60 (48/42/34/32) O 6-12mm ∅ 60/76 O 2.5mm max O 6-12mm ∅ 60 (48/42/34/32) O 6-12mm ∅ (..) 25Nm ∅ 60/76 O 2.5mm max Load Cell Load Product Label...

This manual is also suitable for:

Libra 2566Libra 2565Libra 2570Libra 2567Libra 2571Libra 2572