  • Page 1 A-DC6-100-11 (1) HD CMOS Color Video Camera Command List Version 1.00 BRC-Z330 © 2009 Sony Corporation...
  • Page 2: Table Of Contents

    BRC-Z330 Command List (3/5) ...... 11 BRC-Z330 Command List (4/5) ...... 12 BRC-Z330 Command List (5/5) ...... 13 BRC-Z330 Inquiry Command List (1/3) ..14 BRC-Z330 Inquiry Command List (2/3) ..15 BRC-Z330 Inquiry Command List (3/3) ..16 BRC-Z330 Block Inquiry Command List ..17 VISCA Command Setting Values ....
  • Page 3: Visca Rs-232C/Rs-422 Commands

    0 is used, set the camera address selectors on the connected BRC-Z330 cameras to different numbers............................................. 1) VISCA is a protocol developed by Sony for controlling a consumer’s camcorder. “VISCA” is a trademark of Sony Corporation.
  • Page 4: Visca Communication Specifications

    BRC-Z330 assigned address 2 is 82H. In the command VISCA Communication list, as the header is 8X, input the address of the BRC- Specifications Z330 to X. The header of the reply packet from the BRC-Z330 assigned address 1 is 90H. The packet from the BRC-Z330 assigned address 2 is A0H.
  • Page 5 X0 6Y 03 FF Command buffer full X0 6Y 04 FF Command canceled X0 6Y 05 FF No socket (to be canceled) X0 6Y 41 FF Command not executable X = 9 to F: BRC-Z330 address + 8, Y = socket number...
  • Page 6: Visca Device Setting Command

    IF_Clear (broadcast) 88 01 00 01 FF 88 01 00 01 FF X = 1 to 7: BRC-Z330 address (For inquiry packet) X = 9 to F: BRC-Z330 address +8 (For reply packet) VISCA interface and inquiry • CAM_VersionInq Returns information on the VISCA interface.
  • Page 7: Visca Command/Ack Protocol

    VISCA Command/ACK Protocol Command Command Message Reply Message Comments General Command 81 01 04 38 02 FF 90 41 FF (ACK)+90 51 FF Returns ACK when a command has been accepted, or (Example) (Completion) Completion when a command has been executed. 90 42 FF 90 52 FF 81 01 04 38 FF...
  • Page 8: Visca Camera-Issued Messages

    VISCA Camera-Issued Messages ACK/Completion Messages Command Command Message Comments z0 4y FF Returned when the command is accepted. (y: Socket No.) Completion z0 5y FF Returned when the command has been executed. (y: Socket No.) z = Device address + 8 Error Messages Command Command Message...
  • Page 9: Brc-Z330 Commands

    BRC-Z330 Commands BRC-Z330 Command List (1/5) Command Set Command Command Packet Comments AddressSet Broadcast 88 30 01 FF Address Set IF_Clear Broadcast 88 01 00 01 FF I/F Clear CommandCancel 8x 2p FF p: Socket No (1 to 2) CAM_Power...
  • Page 10: Brc-Z330 Command List (2/5)

    BRC-Z330 Command List (2/5) Command Set Command Command Packet Comments CAM_RGain Reset 8x 01 04 03 00 FF 8x 01 04 03 02 FF Down 8x 01 04 03 03 FF Direct 8x 01 04 43 00 00 0p 0q FF...
  • Page 11: Brc-Z330 Command List (3/5)

    BRC-Z330 Command List (3/5) Command Set Command Command Packet Comments CAM_BackLight 8x 01 04 33 02 FF 8x 01 04 33 03 FF CAM_SpotLight 8x 01 04 3A 02 FF 8x 01 04 3A 03 FF Flicker Reduction 8x 01 04 32 02 FF...
  • Page 12: Brc-Z330 Command List (4/5)

    BRC-Z330 Command List (4/5) Command Set Command Command Packet Comments Color_AE 8x 01 7E 01 55 00 FF ON (NARROW) 8x 01 7E 01 55 01 FF ON (STD) 8x 01 7E 01 55 02 FF ON (WIDE) 8x 01 7E 01 55 03 FF...
  • Page 13: Brc-Z330 Command List (5/5)

    BRC-Z330 Command List (5/5) Command Set Command Command Packet Comments Cmd_dzm_chg E-Zoom Limit 81 01 7E 01 19 0p FF p: 0= ×1.0, 1= ×1.5, 2= ×2.0, 3= ×4.0 Cmd_Color_Bar 81 01 04 7D 02 FF When Power is on, return to off.
  • Page 14: Brc-Z330 Inquiry Command List (1/3)

    BRC-Z330 Inquiry Command List (1/3) Inquiry Command Command Packet Inquiry Packet Comments CAM_PowerInq 8x 09 04 00 FF y0 50 02 FF y0 50 03 FF Off (Standby) CAM_ZoomPosInq 8x 09 04 47 FF y0 50 0p 0q 0r 0s FF...
  • Page 15: Brc-Z330 Inquiry Command List (2/3)

    BRC-Z330 Inquiry Command List (2/3) Inquiry Command Command Packet Inquiry Packet Comments CAM_ExpCompModeInq 8x 09 04 3E FF y0 50 02 FF y0 50 03 FF CAM_ExpCompPosInq 8x 09 04 4E FF y0 50 00 00 0p 0q FF pq: ExpComp Position*...
  • Page 16: Brc-Z330 Inquiry Command List (3/3)

    CAM_Card_StatusInq 8x 09 7E 01 0E FF y0 50 0p FF p: Information on the optional card inserted in the interface card slot of the BRC-Z330 5: BRBK-HD2 F: No Card CAM_EXTSYNC_SynchronousModeInq 8x 09 7E 01 2C FF y0 50 00 FF...
  • Page 17: Brc-Z330 Block Inquiry Command List

    BRC-Z330 Block Inquiry Command List Lens control system inquiry commands…..Command Packet 8x 09 7E 7E 00 FF Byte Comments Byte Comments Byte Comments Destination Address Source Address ND Filter (0: OFF, 1: 1/4, 2: 1/16) 0 Completion Message(50h) D-Zoom Mode...
  • Page 18 Camera control system inquiry commands (1/2)…..Command Packet 8x 09 7E 7E 01 FF Byte Comments Byte Comments Byte Comments Destination Address AWB Sens (1: Low, 2: Mid, 3: High) Manual Gain Position WB Mode Source Address (0: Auto1, 1: Indoor, 2: Outdoor, 3: OnePush, 4: Auto2, 5: Manual) 0 Completion Message(50h)
  • Page 19 Camera control system inquiry commands (2/2)…..Command Packet 8x 09 7E 7E 02 FF Byte Comments Byte Comments Byte Comments Destination Address Source Address Iris Limit (0: F11, 1: F6.8, 2: F4.0, 3: F3.4) 0 Completion Message(50h) Gamma Mode (0: Normal, 1: Cinema) D-Zoom Limit (0: ×1.0, 1: ×1.5, 2: ×2.0, 3: ×4.0)
  • Page 20 Other enlargement inquiry commands (1/2) ..Command Packet 8x 09 7E 7E 03 FF Byte Comments Byte Comments Byte Comments Destination Address R.ENHANCE Gain Pri Position Source Address 0 Completion Message(50h) G.ENHANCE FAN rotating status (1: Rotating, 0: Stop) COLOR DETAIL B.ENHANCE PHASE D-Zoom Position (H)
  • Page 21 Other enlargement inquiry commands (2/2) ..Command Packet 8x 09 7E 7E 04 FF Byte Comments Byte Comments Byte Comments Destination Address prism temp (H) Gain Current Position Source Address 0 Completion Message(50h) prism temp (L) Color AE PHASE 0 - 71 IRIS Position Open F-number limit Current WB R-GAIN (H)
  • Page 22: Visca Command Setting Values

    VISCA Command Setting Values Exposure control Iris Gain IRIS (F1.6) Parameter GAIN (dB) Parameter F No. HYPER F1.6 F1.7 F1.8 F2.0 F2.2 F2.4 F2.6 F2.8 F3.1 F3.4 F3.7 F4.0 F4.4 F4.8 F5.2 F5.6 F6.2 F6.8 F7.3 F8.0 F8.7 F9.6 –3 Iris Limit Parameter F No.
  • Page 23 Zoom Ratio and Zoom Position (for Shutter Speed 1080/59.94i 1080/50i reference) 720/59.94P 720/50P SHUTTER (sec) (sec) Optical Zoom 1/10000 1/10000 Position Zoom Ratio 1/6000 1/6000 × DATA 18 Lens 1/4000 1/3500 0000 ×1 1/3000 1/2500 16DA ×2 1/2000 1/1750 2111 ×3 1/1500 1/1250...
  • Page 24 Focus Ratio and Focus Position (for Pan/Tilt Position (for reference) reference) BRC-L PAN-TILT Absolute value coordinate Focus Ratio Focus Distance Left Right 1000 Over Inf Angle Decimal Hexadecimal Decimal Hexadecimal 2000 (degrees) 3000 1.8 m 00000 00000 4000 1.0 m 00090 –144 FFF70...
  • Page 25: Pan/Tilt Status Code List

    Pan/Tilt Status Code List – – – – – – – – – – – – – Panning reaches the end of the left. – – – – – – – – – – – – – Panning reaches the end of the right. –...
  • Page 26: Memory Function (Inquiry Commands)

    Memory Function (Inquiry Commands) Preset No. pp: Memory number Comments last operated last operated – While no Recall commands are used after the power has been tuned on ≠ 00 (or =00 for Reset, Set and Recall commands)
  • Page 27: Revision History

    Revision History Version Item Description 1.00 New edition...