Operation; Welding Current Calibration; Crater - Panasonic YD-350GL4 Operating Instructions Manual

Digital igbt controlled mig / mag arc welding power source
Table of Contents

Advertisement

9. Operation
Depending on the CHANGE button settings and the use
of "Crater repeat", torch operation varies as follows.
Note
After turning on the torch switch, if the voltage detect is
not executed, the welder goes in an error state (Err6: Arc
start error) and turns off the output automatically.
9.1 Welding current calibration
Welding current is tested and calibrated with following
welding wire extension. it may need readjustment with
Welding current
Extended wire length
(Tip-Base metal distance)
9.2 "NO CRATER"
Operation: Turn the torch switch on and off to start and
stop welding arc respectively.
Torch: ON
① ① ① ①
Arc ON
ON
Torch switch
ON
Gas supply
Wire
slow down
Wire feed
Weld voltage
Weld current
Weld conditions

Operation

0.9
wire
0.8
wire
1.2
wire
1.0
wire
Torch: OFF
② ② ② ②
Tpf
Main welding
moved welding parameters such as torch angle, wire type
, shieling gas and other welding conditions.
50A
100A
150A
12
12
12
15
15
15
Arc OFF
OFF
OFF
Burn-back time
28
200A
250A
300A
15
18
18
18
22
Tpf: Gas pre-flow time
:Arc start
:Arc end
350A
25

Hide quick links: