INAZUMA ITF-30 septem Installation And Operating Instructions Manual

Drum filters

Advertisement

Quick Links

Installation and operating instructions
Drum Filters
ITF-30
septem
ITF-50
septem
ITF-80
septem
ITF-120 septem
ITF-160 septem
ITF-240 septem
ITF-30
Biokompakt septem
ITF-50
Biokompakt septem
ITF-80
Biokompakt septem
ITF-120 Biokompakt septem
ITF-160 Biokompakt septem
ITF-240 Biokompakt septem
Control WebCSA
V2
w w w . i n a z u m a - o n l i n e . c o m
Control WebCSA
V2

Advertisement

Table of Contents
loading

Summary of Contents for INAZUMA ITF-30 septem

  • Page 1 w w w . i n a z u m a - o n l i n e . c o m Control WebCSA Installation and operating instructions Drum Filters ITF-30 septem ITF-50 septem ITF-80 septem ITF-120 septem ITF-160 septem ITF-240 septem ITF-30 Biokompakt septem...
  • Page 2: Table Of Contents

    F I L T E R T E C H N O L O G Y M A D E I N G E R M A N Y Index page General information ....................... 3 1.1. Introduction ...................................3 1.2. Important safety notes and warnings ..........................3 1.3.
  • Page 3: General Information

    1.8. Spare parts Only spare parts provided by Inazuma or one of its 1.3. Warning Label authorized suppliers are approved for installation. In the The sign next to this text points out important event of usage of non-authorized parts the warranty will warnings or significant Informations.
  • Page 4: Transport

    No liability is assumed for damage to the filter caused plan. In the event of deviations and the resulting delays or by improper transport or the use of improper lifting a renewed travel, Inazuma reserves the right to charge the equipment. additional work.
  • Page 5: Warranty

    The installation and connection of the drum filter guarantee in accordance with the following guarantee should only be carried out by qualified personal. conditions. In addition, the guarantee conditions apply, which can be viewed at www.inazuma-online.com. The 2.1. Before installation customer’s statutory warranty rights remain expressly unaffected.
  • Page 6: Installation: Gravity Driven Setup & Water Level

    F I L T E R T E C H N O L O G Y M A D E I N G E R M A N Y 2.3. Installation: gravity driven setup & gravity driven setup water level The filter must be installed on even and solid ground.
  • Page 7: Installation: Pump Driven Setup

    1. To prevent the loss of water in the event of malfunction, remove the premounted sheet metal parts and store them. 2. We recommend powering the pumps using an external system. The Inazuma Control WebCSA provides this function. In case of a malfunction or an error, the Control WebCSA shuts the pumps down automatically.
  • Page 8: Installation Control Webcsa / Initial Commissioning Of The Filter

    (power switch, temperature sensor, would occur. pond level regulation) can be downloaded from our homepage www.inazuma-online.com. Inazuma offers an automatic pond level regulation (item no. IK5001) The WebCSA app can be downloaded in the google play store and apple app store.
  • Page 9: Mounting Of The Two Float Switches

    w w w . i n a z u m a - o n l i n e . c o m 2.6. Mounting of the two float switches The WebCSA control is supplied with two float switches.. Float switch 1 (1 floater) detects the water level in the Float switch 2 (2 floaters) is responsible for flushing and prechamber.
  • Page 10: Mounting Of The Float Switch 2 - Gravity Driven Setup

    F I L T E R T E C H N O L O G Y M A D E I N G E R M A N Y 2.6.2. Mounting float switch 2 (gravity) 2.6.3. Mounting float switch 2 (pumped) Biokompakt-Models: Waste water section in front of the drum Pure water area outside the drum...
  • Page 11: Magnetic Valve For The Gutter Flush

    w w w . i n a z u m a - o n l i n e . c o m 2.7. Installation of the magnetic valve for the gutter flush On delivery, the connection pins of the solenoid valve Now turn the complete solenoid valve back to the starting head point towards the housing wall.
  • Page 12: Immersion-Uvc

    3 fig. 1 fig. 2 All Inazuma septem drum filters have one or several UVC mountings on the inside (suitable for the HD-PRO 50.000 V2 immersion-UVC) (see fig. 1) Assembly: Insert the immersion-UVC into the mounting until the device reaches the fixture. Do this with caution to not damage the quartz glass pipe.
  • Page 13: Mounting Of The Gear Protection Plate

    2.11. Biological filter material Planet Bio We recommended the use of biological filter material In conjunction with the WebCSA app these and other Inazuma Planet Bio in following quantities: parameters can be changed or adjusted. ITF-30 BioKompakt septem 150 liters...
  • Page 14: Maintenance

    F I L T E R T E C H N O L O G Y M A D E I N G E R M A N Y 2.13. Maintenance and care During maintenance and before opening the filter it is necessary to turn it off and to unplug the power cable. Otherwise, there will be a heavy risk of injury.
  • Page 15: Calcification / Faults

    45 l/min on the drum. The safety instructions of the cleaning agent used must be observed! Flow rates (degree of pollution: max. ≤ 10 mg/ℓ) 2.13.5. Winter operation ITF-30 septem ITF-50 septem ITF-80 septem ITF-120 septem ITF-160 septem ITF-240 septem...
  • Page 16: Exploded Drawing And Spare Parts List

    F I L T E R T E C H N O L O G Y M A D E I N G E R M A N Y...
  • Page 17: Certificate Of Quality

    w w w . i n a z u m a - o n l i n e . c o m Zertifikat zur Qualitätssicherung Certificate of quality Trommelfilter Drumfilter Endmontage / Final assembly: Drehrichtung Motor geprüft Direction of rotation of the engine ...
  • Page 18 F I L T E R T E C H N O L O G Y M A D E I N G E R M A N Y...
  • Page 19: Service Order / Repair Note

    Please fill out this form legibly and completely. If you want a warranty repair, a copy of the proof of purchase as proof of the existing warranty claim is mandatory. Send the form with proof of purchase in advance by fax to (+49) 821 - 7291973 or email to info@inazuma-online.com Customar data...
  • Page 20 Eisackstraße 16 DE – 86165 Augsburg Tel.: (+49) 821 / 72 91 97 2 Fax: (+49) 821 / 72 91 97 3 info @ inazuma -online .com www. inazuma- online .com Technical modifications and errors excepted WEEE-Reg.-Nr. DE 19429673 Manual Version 2020-01...

This manual is also suitable for:

Itf-50 septemItf-80 septemItf-160 septemItf-240 septemItf-30 biokompakt septemItf-80 biokompakt septem ... Show all

Table of Contents