If a problem persists, call your supplier or Tamson Instruments b.v. WARRANTY Tamson Instruments b.v. warrants that all their manufactured equipment is free from defects in material and workmanship, preventing the device from normal operation. Tamson Instruments b.v does not warranty that the equipment is fit for any other use than stated in this manual.
INSTALLATION 5.1 Important Tamson Instruments bv is not responsible for any consequential damage or harm caused by using this thermometer. Repairs on the electrical system of the thermometer may only be carried out by well trained and authorized persons.
That means that at least 63 percent of the temperature change is displayed within three seconds. The E20 thermometer is equipped with a 3 mm outer diameter shaft. Differences in response time are indicated in figure 1. 3mm shaft...
Page 7
NL28 INGB 0007 350 370 Van ’t Hoffstraat 12 NL95 RABO 0160100046 2665 JL Bleiswijk, The Netherlands Chamber of commerce 27 16 95 41 T. 31 (0) 10 522 43 73 E-mail: sales@tamson.com Page 7/22 E20 Thermometer man.docx Rev. 3.03 UK 0319 Website: www.tamson.com...
"°F" Digital, "B" 8.3 Communication The communication between PC and E20 thermometer uses a protocol based on addresses. In the microcontroller data is stored in EEProm using memory addresses. The temperature is stored at memory address 376, 377, 378 en 379.
'Byte 7 Checksum, all data is added, last two hex are used. I.e. a value of &h 30D returns 0D as checksum. 8.5 Send and receive In order to receive the actual temperature from the E20 thermometer following hex code must be send to the thermometer: 54 0A 02 01 77 00 00 00 00 (The red value "D9"...
Page 10
NL28 INGB 0007 350 370 Van ’t Hoffstraat 12 NL95 RABO 0160100046 2665 JL Bleiswijk, The Netherlands Chamber of commerce 27 16 95 41 T. 31 (0) 10 522 43 73 E-mail: sales@tamson.com Page 10/22 E20 Thermometer man.docx Rev. 3.03 UK 0319 Website: www.tamson.com...
Tamson instruments offers a software program to generate IEC90 coefficients. 5 coëfficients are needed to linearize and calibrate the E20 thermometer. To do so this program needs 5 reference temperatures at which the ADC value is read from the Thermometer display. A shipped E20 thermometer offers 3 readings: Degree Centigrade, indicated with a "C"...
The data of "Table 1" can now be used to calculate the ITS90 coefficients to linearize the E20 thermometer. The coefficients will linearize the E20 thermometer to within ±0.01°C linearity and accuracy. In the TTT program, select the tab "coefficienten". Data from "Table 1"...
Page 17
NL28 INGB 0007 350 370 Van ’t Hoffstraat 12 NL95 RABO 0160100046 2665 JL Bleiswijk, The Netherlands Chamber of commerce 27 16 95 41 T. 31 (0) 10 522 43 73 E-mail: sales@tamson.com Page 17/22 E20 Thermometer man.docx Rev. 3.03 UK 0319 Website: www.tamson.com...
EN55016-2-3 Radiated emission p (anechoic room) = Pass June 2016, Tamson Instruments bv, The Netherlands Entity responsible for marking this declaration : Manufacturer, Tamson Instruments bv, van 't Hoffstraat 12, Bleiswijk The Netherlands, Name R.C. van Hall Function Director Date...
Need help?
Do you have a question about the E20 and is the answer not in the manual?
Questions and answers