Do you have a question about the 6053-LINK-00 TechBox and is the answer not in the manual?
Questions and answers
Summary of Contents for Parker 6053-LINK-00 TechBox
Page 1
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Page 3
All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker SSD Drives company without written permission from Parker SSD Drives.
Contents Contents....................3 Chapter 1 - An Overview ..............1 6053-LINK-00 TechBox.......................1 6055-LINK-00 TechBox.......................1 LA463610U003 TechCard....................1 Product Features.......................2 Part Number and Identification ..................2 Chapter 2 - Installation ............... 3 Installing the Option ......................3 Wiring ..........................3 Fitting the TechBox to the frame B 605 and 690+ Drives ..........5 Fitting the TechCard to the 584SV .................6...
A computer may be used to provide supervision and monitoring for each drive and other LINK modules in the system. 6053-LINK-00 TechBox This techbox is to be used with the 605 and 690+ frame B. The 6053-L-00 fits into the same location normally Advantages occupied by the keypad.
Product Features • Available for 605, 690+, 590+ and 584SV products • Compact 5H x 3W x 1D inches • Easy snap on installation • Eliminates hard wired signal connections • Standalone processing with built in macros • Auxiliary power supply input for network backup •...
Chapter 2 - Installation Installing the Option WARNING Before installing, ensure that the drive power is switched off and cannot be switched on accidentally by other personnel. Wait 5 minutes after disconnecting power before working on any part of the system or removing the covers from the drive.
Page 9
If you have an older version, updates may be obtained simply by contacting Parker SSD product support. Use the cable that was supplied with your DSD or ConfigEd package. Plug the larger end into your computer serial port (using the DB9to RJ11 adapter supplied), and the other end (RJ15) into the socket on the LINK TechBox/TechCard.
Transmit Strength Settings - Switch (SW1) Set this switch to select the transmission intensity of the light. Use the table below to choose the position after determining the approximate length of the ‘transmit’ fiber optic cable to the next LINK element.
Fitting the TechCard to the 584SV The option is supplied as a “Technology Option” board. It is factory-fitted to the control board inside the drive. Warning Ensure that all power is off prior to working on the drive. Caution When handling the board, observe Technology electrostatic control precautions.
Fitting the TechBox to a 590+ and 605/690+frames C and above The option is supplied as a “6055-L-00 TechBox” which fits into the lower right front of the 605C/690+C - F drive. Note: The 6055-L-00 TechBox does not affect the operation of the 6051/6901 keypad. WARNING! Ensure that all power is off prior to working on the...
Chapter 3 - Initial Set-up Configuring the Drive MMI Menu Map The first step in using the technology option is configuring the drive to accept the TechBox. The keypad (MMI), DSD/ConfigEd (LINK programming software) or ConfigEd Lite (SSD SETUP PARAMETERS Drives’...
Page 14
FAULT Range: Enumerated - see below The fault state of the Technology Option card. Enumerated Value : Fault State 0 : NONE: Normal operating mode. 1 : PARAMETER: Confirm that tag exists in the LINK Configuration. 2 : TYPE MISMATCH: Confirm that type of tag is valid. 3 : SELF TEST: The self test has failed.
Chapter 4 - Using DSD Macros and Templates 590+ and 690+ Macros/Templates The DSD program has pre-configured macros for the 590+ and the 690+. These macros contain a template for the specific drive. The internal drive parameters are programmed via the template and are stored in the TechBox/TechCard.
Page 16
The macro has some preconfigured inputs and outputs as default. If another tag or parameter is needed, it can be added inside the macro. It is possible to use both the drives’ internal function blocks and the Link function blocks. Simply double-click on the macro to access the 590+ internal function blocks.
Page 17
Modifying inside the macro All the drive functions are available through the TechBox. When using some of the 590+ drive functions it may be necessary to use the Mini-Link block or a system block as the connection point to the TechBox. The purpose for doing this is to ensure proper triggering of non-system function blocks.
Page 18
Note: Internal tags do not get a module address or slot address. The tag appears as a connection point on the outside of the macro. Double clicking on the diamond will allow you to change the name of the tag. This name will appear inside and outside the macro. The number preceeding the tag name controls the order of appearance on the macro outside connection points.
Page 19
Using Drive I/O Drive analog and digital inputs are available for use as I/O for the Link system. The 590+ drive requires the use of the MiniLink or system function blocks. The 690+ drive does not require the use of the MiniLink or system blocks. 590+ Analog and Digital I/O 690+ Analog and Digital I/O LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5...
Chapter 5 - Sample Projects To demonstrate the use of a LINK Technology Option, here are two simple projects consisting of a 584SV drive, with a LA463610U003 TechCard, or 690+ drive with a 6053/6055 TechBox and an L5392 touchscreen. Our first example uses a 584SV, the second example uses a 690+. By configuring these pieces, we will build a LINK project that will: •...
Page 21
Figure 2 – (1 of 2) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 22
Figure 2 – (2 of 2) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
LINK Step 3 – Create a Project In ConfigEd, create a new project by using the Project/Manage menu. Refer to the ConfigEd instruction manual HA353792 for details. Step 4 – Configure the TechCard 1. In the selected project, open a default Techbox template by going to File/New/LtechBx2. 2.
Page 24
Figure 4 – (1 of 4) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 25
Figure 4 – (2 of 4) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 26
Figure 4 – (3 of 4) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Page 27
Figure 4 – (4 of 4) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
690+ Macro Sample Configuration Select the 690+ template with the correct version firmware from the “NEW” menu. After completing the above steps you should see the 690+ macro without any Link connections. Make the necessary connections and changes to make the configuration look like Figure 6. LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ...
Page 30
Figure 6 – (1 of 5) LINK TechBox/TechCard Instruction Manual - HA470016 Issue 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
Chapter 6 – Troubleshooting 6053-L-00 LA463610U003 6055-L-00 TECHBOX TECHCARD TECHBOX Model No: 6055-L-00 Serial No: 1234567890ABCD |||||| ||||||||||||||||||| ||||||||| Internal External Health and Run LED’s Health and Run are drive functions and are not associated with the operation of the technology feature.
Network LED This indicates the state of the connected network. LED STATUS DESCRIPTION Network failure Module halted or initializing Network healthy Module peer halted or duplicate address Note: The NETWORK LED can only be in the ON state when the MODULE LED is ON continuously, indicating that the Option is ready for external communications.
Page 37
• Double-click the Ordinal Diagnostic function block. Selecting the Set Tag # option, enter the Tag number of the parameter you wish to monitor, as shown below. • To read data from the tag just selected, click on Get Data. The instantaneous value (snap shot) will appear on the scratch pad.
• Double-click the Value Diagnostic function block. Selecting the Set Tag # option, enter the Tag number of the parameter you wish to monitor, as shown below. • To read data from the tag just selected, click on Get Data. The instantaneous value (snap shot) will appear on the scratch pad.
WARNING LINK configurations should be created by qualified personnel who have a thorough understanding of drive systems and who are LINK trained by Parker SSD Drives. Potentially dangerous configurations are possible and Parker SSD Drives is not responsible for any resulting consequences or damages.
• No user settings are necessary for this block. When the Tag Load input goes high, the ‘loadable’ writers insert their current values to the respective drive tags. Double-click on the System Control block to access the three restart preferences, as shown above.
Speed values A drive running at full line speed may need to exceed that speed to satisfy a controlled variable. 100% of drive speed = 83.3333% in LINK which is the same as 120% of drive speed = 100% in LINK Example: A line speed signal from a LINK Master Ramp to a drive section.
Page 42
Ordinal Writer Function Block From the Block/Techbox menu select Ordinal Writer. Drag and place it towards the right edge of your sheet. Input terminal Double-click on it and select settings, as shown below. • Select the tag number associated with the parameter to be written to. This may be found under “Specification Table –...
Page 43
Value Writer Function Blocks From the Block/Techbox menu select any Value writer. Drag and place it towards the right edge of your sheet. Input terminal Double-click on it and select settings, as shown below. • Select the tag number associated with the parameter to be written to. This may be found under “Specification Table –...
Page 46
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
Need help?
Do you have a question about the 6053-LINK-00 TechBox and is the answer not in the manual?
Questions and answers