Feig Electronic ID ISC.LR.WS-A Installation Manual
Feig Electronic ID ISC.LR.WS-A Installation Manual

Feig Electronic ID ISC.LR.WS-A Installation Manual

Hide thumbs Also See for ID ISC.LR.WS-A:

Advertisement

Quick Links

INSTALLATION
ID ISC.LR.WS-A Wiegand Switch
(4955.000.00)
Functional Description and Installation
final – public (B)
2018-02-15 – M80211-0e-ID-B.docx

Advertisement

Table of Contents
loading

Summary of Contents for Feig Electronic ID ISC.LR.WS-A

  • Page 1 INSTALLATION ID ISC.LR.WS-A Wiegand Switch (4955.000.00) Functional Description and Installation final – public (B) 2018-02-15 – M80211-0e-ID-B.docx...
  • Page 2 FEIG ELECTRONIC call explicit attention that devices which are subject of this document are not designed with components and testing methods for a level of reliability suitable for use in or in connection with surgical implants or as critical components in any life support systems whose failure to perform can reasonably be expected to cause significant injury to a human.
  • Page 3: Table Of Contents

    Installation Wiegand Switch Contents 1. Abbreviated terms 2. Safety Instructions / Warning - Read before start-up ! 3. Characterization ID ISC.LR.WS-A 3.1. Scope of delivery ....................... 7 3.2. Reader Support........................7 4. Dimensions 5. System Architecture 6. Connector description of the Wiegand Switch 6.1.
  • Page 4: Abbreviated Terms

    IDENTIFICATION Installation Wiegand Switch 1. Abbreviated terms Antenna Data-0 Data-1 Ground Input Input/Output Output Relay RFID Radio-Frequency Identification Ultra High Frequency FEIG ELECTRONIC GmbH Page 4 of 18 M80211-0e-ID-B.docx...
  • Page 5: Safety Instructions / Warning - Read Before Start-Up

    Use of the device and its installation must be in accordance with national legal requirements and local electrical codes .  When working on devices the valid safety regulations must be observed. FEIG ELECTRONIC GmbH Page 5 of 18 M80211-0e-ID-B.docx...
  • Page 6: Characterization Id Isc.lr.ws-A

    IDENTIFICATION Installation Wiegand Switch 3. Characterization ID ISC.LR.WS-A The Wiegand Switch is an additional interface device which allows you to route the Wiegand signal of a FEIG RFID reader to two different input channels of an access control panel. Switching between the output channels of the Wiegand Switch is controlled by the readers relay.
  • Page 7: Scope Of Delivery

    Table 1: Product order information Part Number Product Name 4955.000.00 ID ISC.LR.WS-A Wiegand-Switch 3.2. Reader Support The Wiegand Switch can be used with the following FEIG devices: Table 2: Supported Reader types if Wiegand Switch is used for two lanes...
  • Page 8: Dimensions

    IDENTIFICATION Installation Wiegand Switch 4. Dimensions The ID ISC.LR.WS-A is designed for DIN hat rail mounting (according to DIN EN 50 022) and is therefore especially suited for use in industrial housings. 99 mm 90 mm 22,5 mm FEIG ELECTRONIC GmbH Page 8 of 18 M80211-0e-ID-B.docx...
  • Page 9: System Architecture

    If the reader relay is switched off (default state) the Wiegand Switch uses its Wiegand Output A. If the relay is switched active the Wiegand signal will be routed to Wiegand Output B. Figure 2: System Architecture FEIG ELECTRONIC GmbH Page 9 of 18 M80211-0e-ID-B.docx...
  • Page 10: Connector Description Of The Wiegand Switch

    Figure 3: Available Connectors gives an overview on the different connectors of the Wiegand Switch, the reader and the used Access Control Panel. Figure 3: Available Connectors Figure 4: Connector overview X1 – X4 FEIG ELECTRONIC GmbH Page 10 of 18 M80211-0e-ID-B.docx...
  • Page 11: Power Supply

    The supply voltage of 12-24 V DC must be connected to connector X1 of the Wiegand Switch. Figure 5: Pin Assignment at connector X1 Signal X1-GND Ground X1-VCC 12-24 V DC Table 4: Pin assignment at connector X3 FEIG ELECTRONIC GmbH Page 11 of 18 M80211-0e-ID-B.docx...
  • Page 12: Inputs

    5 V DC Signal to drive the outputs of the reader X2-OUT2 E/D1 Data-1 Signal of the readers Wiegand Output X2-OUT2 C/ 5V 5 V DC Signal to drive the outputs of the reader FEIG ELECTRONIC GmbH Page 12 of 18 M80211-0e-ID-B.docx...
  • Page 13: Wiegand Outputs D0, D1 (5V Ttl)

    D1 at Input 1 of the Access Controller (5V TTL) X3-GND Common Ground X4-B D0 D0 at Input 2 of the Access Controller (5V TTL) X4-B D1 D1 at Input 2 of the Access Controller (5V TTL) X4-GND Common Ground FEIG ELECTRONIC GmbH Page 13 of 18 M80211-0e-ID-B.docx...
  • Page 14: Dip-Switch Settings

    (EU: 4127.001.00; FCC: 4128.001.00) Use with ID ISC.LRU3x00 and ID ISC.LR(M)2500 and ID ISC.LRU1002 (EU: 4127.000.00; FCC: 4128.000.00) NOTE: The setting of the DIP Switch 1-2 should always be set in pairs FEIG ELECTRONIC GmbH Page 14 of 18 M80211-0e-ID-B.docx...
  • Page 15: Indicators Leds

    Installation Wiegand Switch 8. Indicators LEDs The Wiegand Switch has two green LEDs which indicates the active Wiegand output A or B. Figure 9: shows the position of the two green LEDs FEIG ELECTRONIC GmbH Page 15 of 18 M80211-0e-ID-B.docx...
  • Page 16: Technical Data

    EN 60068-2-6 Vibration 10 Hz up to 150 Hz: 0,075 mm / 1 g EN 60068-2-27 Shock Acceleration: 30 g Applicable Standards - EMC EN 301 489 - Safety EN 32 368 FEIG ELECTRONIC GmbH Page 16 of 18 M80211-0e-ID-B.docx...
  • Page 17: Wiring And Configuration Examples

    IDENTIFICATION Installation Wiegand Switch 10. Wiring and Configuration Examples 10.1. ID ISC.LRU1002 10.1.1. Wiring Figure 10: Wiring Example for ID ISC.LRU1002 FEIG ELECTRONIC GmbH Page 17 of 18 M80211-0e-ID-B.docx...
  • Page 18: Configuration

    Table 9: Settings for 2 Gates with 2 antennas per lane Gate Antenna assignment Read Event Activation Output Wiegand Switch ANT1 False OUT A ANT2 False OUT A ANT3 True OUT B ANT4 True OUT B FEIG ELECTRONIC GmbH Page 18 of 18 M80211-0e-ID-B.docx...

Table of Contents