Page 1
Neurolief Relivion™ User Manual Relivion ™ User Manual...
Page 2
No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system or translated into any language or any computer language, in any form or by any third party, without the prior written permission of Neurolief Ltd. Any software described in this publication is furnished under a license agreement.
Page 3
System Symbols Neurolief Relivion™ User Manual User Manual Purpose This user manual provides the necessary instructions for safely operating the Relivion ™ in accordance with its function and intended use. These instructions include – • An explanation of the function of controls and indicators.
Page 4
Catalog number. Operating conditions Keep dry. IP rating. Indicates the degree of protection. IP54 The Relivion™ device is protected from limited dust ingress and from water spray from any direction. RF transmitter. Waste Electrical and Electronic Equipment Directive (WEEE). Safety Information...
Page 5
Keep the device out of reach of children. • Use this device only with Neurolief electrode pads and the Neurolief charger supplied with the device. Do not use any accessories, detachable parts and materials that are not provided by Neurolief.
Page 6
Conventions Used in This User Manual NOTE Notes provide additional important information. Tips indicate helpful information for using the Relivion™. WARNING! Warnings indicate conditions or practices that may result in damage to the equipment or minor/moderate injury to the patient.
™ ................13 STEP 2, ADJUSTING THE RELIVION TO FIT YOUR HEAD ......... 15 ™ STEP 3, GETTING STARTED WITH THE RELIVION APP ..........19 ™ Chapter 3 – Using the Device ..............21 OPERATING BUTTONS AND INDICATORS ..............21 STEP 1, PREPARING FOR TREATMENT ................
Page 8
Table of Contents Neurolief Relivion™ User Manual Blank page for double-sided printing...
To ensure safe and proper usage, you should review this entire IMPORTANT! user manual carefully before using the Relivion™ device. Contact Neurolief customer support at +972 (9) 3730288 or visit the Neurolief website at www.neurolief.com if you have any questions.
™ stimulation of the target nerves. The on-board stimulation circuit is adapted to deliver stimulation patterns to enhance proper nerve activation. The Relivion adjusts to ™ various head sizes and contours and can be worn comfortably. Each time it is worn, the six electrodes are placed over the underlying nerves.
Introducing Relivion™ Neurolief Relivion™ User Manual Relivion System Kit Contents ™ Carrying Case Do not use other accessories than those provided with the Relivion kit. ™ RELIVION HEADSET ™ The Relivion headset can be comfortably worn on the head during treatment. It ™...
Page 12
Introducing Relivion™ Neurolief Relivion™ User Manual Blank page for double-sided printing...
When the battery is low, the battery indicator light blinks yellow. After the device is fully charged, it is typically sufficient for approximately five hours of treatment. IMPORTANT! Only use the charger supplied with the Relivion device. ™ ...
Page 14
Getting Ready Neurolief Relivion™ User Manual NOTE Ensure that the charger socket is not wet before charging the device. Connect the magnetic connector of the charger to the charging socket on the headset. The charging socket is located on the bottom of the headset. The connector connects using magnetic force.
TO FIT ™ YOUR HEAD Perform the procedure below to adjust the Relivion to fit your head. ™ You only need to make these adjustments once, before using the Relivion for the ™ first time. To adjust the Relivion to fit your head –...
Page 16
To do so, follow the steps below – Place the magnet ends of the arms at the sides of your head (slightly above ▪ your ears). Figure 10: Placing the Relivion Arms on Your Head Above the Ears ™...
Page 17
Getting Ready Neurolief Relivion™ User Manual Push the device backwards so that the arms penetrate under your hair. ▪ Figure 11: Pushing the Device Backwards on your Head NOTE Be sure to place the device arms under your hair. Check to see if the magnets at the ends of each arm meet at the back of ▪...
Page 18
Getting Ready Neurolief Relivion™ User Manual If the magnets do meet at the back of the head, then position your fingers on ▪ the back and front grips and gently pull the grips toward each other to tighten the device on your head.
Getting Ready Neurolief Relivion™ User Manual Remove the device and check the headset arms’ settings (numerical scale) to ensure that they are symmetrical. The size setting for both arms must be the same. Remove the device and check whether they are. If they are not, adjust each arm’s lengths so that both are the same length, and then repeat step...
Page 20
Getting Ready Neurolief Relivion™ User Manual Blank page for double-sided printing...
Using the Device This chapter describes how to prepare, connect and use the Relivion ™ Preparing for Treatment Step 1 Section 3.2 Step 2 Section 3.3 Performing Treatment OPERATING BUTTONS AND INDICATORS Figure 16 shows the Relivion operating buttons and indicators.
Page 22
Using the Device Neurolief Relivion™ User Manual Indicator Description Function Light Shows the status of the Relivion , as ™ Device Status indicator described in Table 4. Shows the status of the battery, as Battery indicator light described in Table 4.
Figure 17: Turning ON the Device The Relivion app connects to the Relivion via Bluetooth. Be sure that ™ ™ Bluetooth is enabled on your mobile phone to make the necessary connection. Click the icon on your mobile phone to launch the Relivion application. ™...
Page 24
Using the Device Neurolief Relivion™ User Manual Follow the on-screen instructions to log in to the mobile app and register your device. Figure 18: Login Screen Figure 19: Device Registration Screen Note that the image on the Registration screen indicates where the serial...
Page 25
Using the Device Neurolief Relivion™ User Manual After the app successfully connects to the Relivion , the following window ™ displays. The Device Status indicator should be illuminated on the app. Figure 20: Successful Connection Tap the Press to Start button on the mobile application.
Page 26
Using the Device Neurolief Relivion™ User Manual Move the nozzle of the bottle up 45 degrees, and then press 8 times for each of the four pads on the front electrodes and 16 times for each pad on the two back electrodes.
Page 27
Using the Device Neurolief Relivion™ User Manual Place the headset on your head. While holding the Relivion arms away from ™ one another, place the tips of the arms at the sides of your head (above your ears) and push the device backwards so that the arms penetrate under your hair and lock to each other by the magnets.
Page 28
Using the Device Neurolief Relivion™ User Manual Verify the position of the headset by looking in a mirror to see that the device is positioned properly. The nose bridge should be centered on your nose and the front portion of the headset should be placed as close as possible to your eyebrows without covering them.
When using the mobile app, click the after you perform this step to move to the next screen in the mobile app wizard. STEP 2, PERFORMING TREATMENT Follow the procedure below to perform treatment using the Relivion device. ™ NOTE It is not mandatory to use the mobile app to perform treatment.
Page 30
Using the Device Neurolief Relivion™ User Manual Figure 31: Initiating Treatment (Mobile App)
Page 31
NOTE The sensation should be strong enough to relieve the headache, but tolerable and comfortable enough for prolonged treatment. The treatment automatically ends after 60 minutes. The Relivion beeps (nine ™ times) and the status indicator light stops blinking and turns off.
Page 32
Using the Device Neurolief Relivion™ User Manual Blank page for double-sided printing...
Troubleshooting and Maintenance This chapter describes how to troubleshoot and clean the Relivion ™ TROUBLESHOOTING The following section describes how to troubleshoot various issues that may arise on the Relivion ™ Should a technical problem occur that is not covered below or that cannot be resolved by the suggested solutions below, contact customer support.
Page 34
Troubleshooting and Maintenance Neurolief Relivion™ User Manual Problem/Symptom Description If you are using the app, it indicates • which electrodes have faulty contact. To solve the problem, remove the headset from your head, wet the identified electrode pads and put the headset on your head again.
Troubleshooting and Maintenance Neurolief Relivion™ User Manual Problem/Symptom Description The battery is depleted. Charge your Relivion ™ The device does not turn ON. device, as described in the Step 1, Charging the Relivion section on page 13. ™ The status indicator ( ) is a Indicates a device malfunction.
Page 36
Troubleshooting and Maintenance Neurolief Relivion™ User Manual Blank page for double-sided printing...
Technical Specifications This chapter describes the technical specifications of the Relivion ™ Table 7: Technical Specifications Operating Conditions Temperature +5°C to +40°C Relative Humidity 15% to 93% Atmospheric Pressure 700 hPa to 1060 hPa Transport and Storage Conditions Temperature -25°C to +70°C...
Page 38
Technical Specifications Neurolief Relivion™ User Manual Maximum Average Power 0.0000116 front electrodes/0.000034 back Density (W/cm electrodes Maximum Rise Time 5 µsec Timer 60 minutes Power Source Battery Type Rechargeable 3.7V Li-Po battery, 200 mAh Battery Life 300 charge cycles Charging Source...
Electromagnetic Compatibility The Relivion is intended for use in the electromagnetic environment specified below. The user should ensure that it is used in such an environment. Table 8: Manufacturer's Declaration – Electromagnetic Emissions Electromagnetic Environment – Emissions Test Compliance Guidance The Relivion™...
Page 40
Electromagnetic Compatibility Neurolief Relivion™ User Manual Table 9: Manufacturer's Declaration – Electromagnetic Immunity Electromagnetic Environment Immunity Test IEC 60601 Test Level Compliance Level – Guidance Floors should be wood, concrete Electrostatic or ceramic tile. If floors are • 8kV contact •...
Page 41
Electromagnetic Compatibility Neurolief Relivion™ User Manual Electromagnetic Environment Immunity Test IEC 60601 Test Level Compliance Level – Guidance Power frequency magnetic Power frequency fields should be at levels (50/60 Hz) 30 (A/m) 30 (A/m) characteristic of a typical magnetic field...
Portable RF communications equipment (including peripherals such as antenna cables and external antennas) should be used no closer than 30 cm (12 inches) to any part of the Relivion™ device, including cables specified by the manufacturer. Otherwise, degradation of the performance of this equipment...
FCC Compliance This device complies with Part 15 of the FCC Rules. Operation is subject to the following conditions – This device may not cause harmful interference. This device must accept any interference received, including interference that may cause undesired operation. FCC ID: 2AO9M-01 WARNING! Modifications not expressly approved by the manufacturer could...
Page 44
Neurolief Ltd. 12 Giborei Israel Netanya, Israel Tel: +972-9-3730288 MAN1001A Rev.1.1 (for model type RLV3)
Need help?
Do you have a question about the Relivion and is the answer not in the manual?
Questions and answers