Technische Gegevens; Technical Specifications - RADSON EURO HPV Series Installation Manual

Sanitary accumulation tank
Table of Contents

Advertisement

model / modell
totale capaciteit (nuttig volume)
total capacity
ø zonder isolatie
ø without insulation
ø met isolatie
ø with insulation
hoogte
height
hoogte met isolatie
height whit isolation
aanvoer sanitair warm water
outlet hot water
aanvoer vaste warmtewisselaar
inlet heat exchanger
hercirculatie
recirculation
thermometer
thermometer
retour vaste warmtewisselaar
outlet heat exchanger
aanvoer koud water
inlet water cold
flens
flange
anode
anodo
elektrische weerstand
electrical resistance
thermometer
anode
anodo
aanvoer sanitair warm water
outlet hot water
warmteoverdrachtsopp. vaste warmtewisselaar
fixed heat exchanger surface
inhoud vaste warmtewisselaar
fixed heat exchnager content
leeggewicht
empty weight

technische gegevens

- Maximale bedrijfsdruk: 10 bar (sanitair),
6 bar spiraalelement
- Maximumtemperatuur van het opgeslagen water
bij voortdurende werking: 95 °C
- Testdruk: 15 bar
- Anorganisch geëmailleerd (glazuur)
- Isolatie in hard polyurethaanschuim, dikte 50 mm
voor model 200, 300 en 500, in zacht polyester, dikte
100 mm voor model 1000
- SKY isolatiebekleding in grijs pvc.
- Conform art. 4 lid 3, Richtlijn Drukapparatuur 2014/68/EU
- Conform DIN 4753.3 en UNI 10025
NB: In het sanitaire circuit moeten naast de tank een
veiligheidsklep met een maximale kalibratie van 6 bar en
een expansievat dat geschikt is voor het volume van de
sanitaire installatie worden geïnstalleerd.
ref.
200 / 300
500
A
B
C
D
1"
1"
E
1"
1"1/4
F
1/2"
1/2"
G
-
-
H
1/2"
1/2"
I
1"
1"1/4
L
1"
1"
M
DN 180
DN 180
DN 180
N
-
-
O
1"1/2
1"1/2
P
1/2"
1/2"
Q
1"1/2
1"1/2
R
1"1/4
1"1/4

technical specifications

- Maximum operating pressure: 10 bar (sanitary),
- Maximum continuous operating temperature
- Testing pressure: 15 bar.
- Inorganic enamelling (vitrification).
- Insulation: in rigid expanded polyurethane thickness
- Insulation coating SKY Grey PVC.
- In compliance with directive PED 2014/68/EU, art. 4.3.
- In compliance with DIN 4753.3 and UNI 10025.
Note: in the sanitary circuit near of the boiler must be
installed a safety valve with calibration maximum = 6 bar
and the expansion vessel adapted to the volume of the
sanitary system.
Euro
1000
u.m.
HPV200
HPV300
190
mm
500
mm
600
mm
1215
mm
1215
1"1/4
mm
1070
1"1/4
mm
990
1"
mm
835
1"
mm
-
1"
mm
370
1"1/4
mm
220
1"1/4
mm
140
mm
320
1"1/2
mm
-
1"1/2
mm
735
1/2"
mm
995
boven
1"1/2
mm
up
boven
-
mm
up
m
2
3,0
17,2
kg
120
6 bar heat exchanger
accumulation: 95 °C.
50 mm for models 200, 300 and 500, in soft
polyester thickness 100 mm model 1000.
technische gegevens
technical specifications
Euro
Euro
Euro
HPV500
HPV1000
263
470
900
500
650
790
600
750
990
1615
1705
2140
1615
1705
2205
1390
1415
1940
1310
1330
1830
1165
1170
1615
-
-
1485
395
425
515
220
270
345
140
185
240
340
370
470
-
-
470
945
970
1435
1390
1425
1940
boven
boven
boven
up
up
up
boven
boven
up
up
4,0
6,0
8,0
23,0
50,5
68,5
160
220
320
3 |

Advertisement

Table of Contents
loading

This manual is also suitable for:

Euro hpv300Euro hpv200Euro hpv500Euro hpv1000