LCN GT12 Installation Manual

Sensor-keypad with 12 keys, bargraph-display and temperature sensor

Advertisement

Quick Links

LCN-GT12
®
Sensor-keypad with
The LCN-GT12 (LCN-GTS12) is a 12-key sensor-keypad with
indication value display for the T-Port.
The integrated temperature sensor can be used on LCN
modules with 1706.. firmware (Juni 2013) or after.
The bargraph-display is able to show analogical actual and
set values.
The sensor keys are each equipped with an additional status-
LED and a blue background light.
®
A corona - surrounding light with white LED´s, serves as a
decorative wall light (LCN-NUI required) and can be switched
as a decent orentation light, so that the LCN-GT12 can also be
operated in darkness.
The 12 capacitive working sensor keys are situated behind a
5mm thick glass front. A soft touch to the surface is enough to
trigger off the functions. The captions on the sensor keys can
be carried out individually per inlay and can be changed
anytime without difficulty.
Installation guide
12 keys, bargraph-display and temperature sensor
LCN-GTS12
®
A1
A2
optional
L1
L2
A3
A4
L3
L4
A5
A6
L5
L6
A7
A8
L7
L8
B1
B2
L9
L10
B3
B4
L11
L12
1

Advertisement

loading

Summary of Contents for LCN GT12

  • Page 1 A corona - surrounding light with white LED´s, serves as a decorative wall light (LCN-NUI required) and can be switched as a decent orentation light, so that the LCN-GT12 can also be operated in darkness. The 12 capacitive working sensor keys are situated behind a 5mm thick glass front.
  • Page 2 15m & inlay sheet (blank). How it functions The sensor keys of the LCN-GT12 (LCN-GTS12) react to a touch on the glass surface. Depending on the duration of touch, an appropriate LCN-control command (Hit, L ) will be sent. When no changes are made to the default key settings, (see page 5:...
  • Page 3 Important: The LCN-GT12 must not “wobble” on the wall, as this would lead to false triggering. That is why when installing, the edges of the cavity wall mounted box should be...
  • Page 4 LCN-GTS12 ® ® Installation guide counter-sunk, to guarantee a flawless function of the LCN-GT12 (LCN-GTS12). When installing a Kaiser double cavity wall box, the separating strip in the middle should be removed. When installing, firstly join the T-port cable to the connected UP(x) module and the screw onto the wall.
  • Page 5 ® Installation guide Getting into operation Requirements: LCN Bus module with firmware 1706.. (June 2013) or after, if you do not use the integrated temperature sensor, even with 120C05 (December 2010) or after. Settings: The LCN-GT12 (LCN-GTS12) will be automatically recognized from the module and the temperature registered in the variable 3 - you can check the value in the analogue status window of the LCN-PRO.
  • Page 6 Pull the plastic slide to the side (outwards) at the rear of the key-sensor. Insert the inscripted inlay at the bottom side of the LCN-GT12 (LCN-GTS12) into the groove until it resists. Tip: If you cut off the corners of the inlay around 2 mm, it will make it easier for inserting the inlay into the groove.
  • Page 7 The power supply LCN-NUI is connected to the I-Port of any module with year of manufacture 2013 or later, and supplies the T-Port over the module.
  • Page 8 Function keys: 12 capacitive sensor areas behind 5mm glass with the functions Hit / L REAK LED´s: 12 LED´s for displaying LCN status messages functions: O , 2 brightnesses LINKS LICKERS bargraph-display with 15 LED´s for showing variables or output values, switchable over command key background LED´s (blue), funktions: O...

This manual is also suitable for:

Gts12