Sensor-keypad with 12 keys, bargraph-display and temperature sensor

Advertisement

LCN-GT12
LCN-GTS12
®
®
Installation guide
Scope of delivery
LCN-GT12 (LCN-GTS12), T-port connection cable, mounting plate, 4 screws 3,2 x
15m & inlay sheet (blank).
How it functions
The sensor keys of the LCN-GT12 (LCN-GTS12) react to a touch on the glass surface.
Depending on the duration of touch, an appropriate LCN-control command (Hit, L
or
ONG
R
) will be sent. When no changes are made to the default key settings, (see page 5:
ELEASE
Key mapping), the keys work as follows: 8 keys work on the A table and 4 keys work on the
B table, according to their numbering.
There is the possibility to trigger 8 further additional keys, through touching two keys
at the same time. Key A1+A2 trigger D1, A3+A4 trigger D2, A5+A6 trigger D3, A7+A8
trigger D4, B1+B2 trigger D5, B3+B4 trigger D6, A1+B4 trigger D7, A2+B3 trigger D8.
This kind of double touching is especially suitable for functions, that should not be
accidentally triggered. (central-off, switching the alarm system, etc)
The integrated temperature sensor supplies the measured values with a triggering from
0,1°C, and thanks to its adaptive average calculation, practically noiseless.
The 12 Status-LED´s in the sensor areas are individually controlled over the T-Port and