PLEASE READ THE MANUAL THOROUGHLY PRIOR TO
EQUIPMENT SET-UP, OPERATION AND MAINTENANCE.
NOTICE: Use this appliance for its intended purpose as described in this User Manual.
GENERAL INSTRUCTIONS
• When the cooler is installed or used, all the packaging (including carton and plastic wrap) should be removed.
• Keep the cooler stable to avoid vibration and noise.
• The cooler should be installed in a place with good ventilation and a space of at least 4" should be allowed
between the surrounding walls and the cabinet wall for air circulation.
• Unit should be placed far from any heating source to avoid decrease of refrigeration efficiency.
• Install the cooler in a dry place to prevent rust from forming on the compartment body, which may affect the
electrical insulation.
CAUTION
• The cooler must be grounded correctly, never to a heating pipe or water pipe. In case of damage to electrical
cord and plug, please contact after-sale service — never do it yourself.
• When unplugging unit, please grasp by the plug, not by the cord.
• If the voltage is unstable, please use a suitable automatic voltage regulator.
• If the power cuts off, you should wait for at least 5 minutes before turning on the unit again to avoid damage to
the compressor.
• Never store any flammable, explosive or corrosive liquid or gas in or near the cooler.
SAFETY
When using electrical appliances, basic safety precautions should be followed:
• This unit must be properly installed and located in accordance with the installation instructions prior to use.
• Do not allow children to climb, stand on or hang from the shelves in the cooler. This could damage the unit and
cause serious injuries.
• Do not store or use gasoline or other flammable vapours and liquids in the vicinity of this or any other appliance.
• Unplug the unit from the electrical outlet before cleaning or making repairs.
• Setting the temperature controls to the 0 (zero) position does not remove power to the light circuit, perimeter
heaters or evaporator fans.
NOTE: It is strongly recommended that any servicing be performed by an certified technician.
Back Bar & Beer Dispenser
RXBB-2472, RXBB-2472G
RXBB-2448G, RXBB-2448G
Commercial Refrigerator and Freezer
USER'S MANUAL
Reliant_Back Bar_User Manual_Jan19
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the RXBB-2472 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Reliant RXBB-2472

  • Page 1 Commercial Refrigerator and Freezer USER’S MANUAL Reliant_Back Bar_User Manual_Jan19 For complete specifications on all Reliant products, please visit www.paragondirect.ca Back Bar & Beer Dispenser RXBB-2472, RXBB-2472G RXBB-2448G, RXBB-2448G PLEASE READ THE MANUAL THOROUGHLY PRIOR TO EQUIPMENT SET-UP, OPERATION AND MAINTENANCE.
  • Page 2: Installation

    Reliant_Back Bar_User Manual_Jan19 PRECAUTIONS FOR R-290 REFRIGERATION 1. Leave enough space between the cabinet and the wall and ceiling; do not enclose or seal off the back part of the cabinet; ensure adequate air movement exists. Caution: Leave a minimum 4" space between the cabinet back and any walls or obstructions. 2.
  • Page 3 Reliant_Back Bar_User Manual_Jan19 BEER DISPENSING SYSTEM DRAFT BEER TOWER INSTALLATION...
  • Page 4 Reliant_Back Bar_User Manual_Jan19 REMOTE CO2 GAS CYLINDER INSTALLATION 1. Remove plug on the right wall with a pair of pliers. 2. Drill and bore hole through the wall,holes can be located in two different areas. 3. Insert CO2 line through the hole. 4.
  • Page 5: Sealing Cabinet To Floor

    Reliant_Back Bar_User Manual_Jan19 SEALING CABINET TO FLOOR Step 1 – Position Cabinet: Allow a minimum of four inches between the wall and rear of the refrigerated bar equipment to assure proper ventilation. Step 2 – Level Cabinet: Cabinet should be level side-to-side and front-to-back. Place a carpenter’s level in the interior cabinet floor in four places: - Position level in the inside floor of the unit near the doors, parallel to cabinet front.
  • Page 6: Maintenance And Cleaning

    Reliant_Back Bar_User Manual_Jan19 MAINTENANCE AND CLEANING Condensers accumulate dirt and dust and require cleaning every 30 days. Dirty condensers result in compressor failure, product loss, and lost sales — which are not covered by warranty. Air is pulled through the condenser continuously along with dust, lint, grease, etc. If you keep the condenser clean you will minimize your service expense and lower your electrical costs.
  • Page 7: Stainless Steel Care And Cleaning

    Reliant_Back Bar_User Manual_Jan19 STAINLESS STEEL CARE AND CLEANING Recommended cleaners for stainless steel: • Soap, ammonia and detergent medallion applied with a soft cloth or sponge for routine cleaning. • Arcal 20, Loc-O-Nu Ecoshine provide a barrier film for fingerprints and smears. •...
  • Page 8: Troubleshooting

    Reliant_Back Bar_User Manual_Jan19 TROUBLESHOOTING Before requesting any service on your unit, please check the following points. Please note that this guide serves only as a reference for solutions to common problems. SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION Compressor Fuse blown or circuit breaker tripped. Replace fuse or reset circuit breaker.