Download Print this page
Maser TORRANT-V2 User And Installation Manual

Maser TORRANT-V2 User And Installation Manual

Ultrasonic rodent repellent

Advertisement

Quick Links

MASER TORRANT-V2
ULTRASONIC
RODENT REPELLENT
User and Installation Manual
Maser Electronics Pvt. Ltd., Mumbai.
support@maserindia.com
www.maserindia.com
022 4111 0000 (100 Lines)

Advertisement

loading
Need help?

Need help?

Do you have a question about the TORRANT-V2 and is the answer not in the manual?

Questions and answers

Summary of Contents for Maser TORRANT-V2

  • Page 1 MASER TORRANT-V2 ULTRASONIC RODENT REPELLENT User and Installation Manual Maser Electronics Pvt. Ltd., Mumbai. support@maserindia.com www.maserindia.com 022 4111 0000 (100 Lines)
  • Page 2 The TorranT V2 Model supports the following protocols on RS/485 CRMS which is our proprietary protocol. Modbus. By default when the system is switched ON it operates on CRMS protocol. There are two modes of operation AUTO Mode and MANUAL Mode. By default the system runs on Auto Mode with factory preset setting (kindly refer below table) In this mode the Wave speed and Wave density parameters will change automatically.
  • Page 3 PANEL KEYPAD OPERATIONS Page 3...
  • Page 4 Password Entry to Access Setup Press Enter Machine Password as mentioned above in the table by doing the following. to change the correct digit (9999). Press to access the setup. Transducer Testing Press Enter Machine Password as mentioned above in the table Press then to choose ‘Test Setup’...
  • Page 5: Parameter Setup

    Press two times to go back to the main Menu and after 30 seconds controller will start displaying all the con gured parameters. Parameter Setup Mode of Operation – Manual Mode First change the mode of operation to Manual Mode. Steps are as follows. Press 1.1.
  • Page 6: Restore Factory Settings

    1.5.c. Press then for changing the values of other parameters. Press to go back main menu. Go to step 1.5 if you wish to change another parameter else after 30 seconds controller will start displaying all the con gured parameters. Restore Factory Settings Press Enter Machine Password as mentioned above in the “Password Entry to Access...
  • Page 7 CRMS Mode Press Enter Machine Password as mentioned above in the “Password Entry to Access Setup”. Press three times to choose ‘System Setup’ parameter. Press then to choose RS-485 Mode. Press to choose CRMS Mode. Press again system will con gure to CRMS Mode. Press two times to go back main menu.
  • Page 8: Modbus Mode

    Press then to choose RS-485 Mode. If your system is in MODBUS Mode. Press then to choose CRMS Mode. Press again system will con gure to CRMS Mode. Press then to select CRMS ID (MID). Press then to con gure MID (0-255). Press and System will con gure to CRMS with respective MID.
  • Page 9 Press then to choose MODBUS Mode. Press again system will con gure to MODBUS Mode. Press two times to go back to main menu. MODBUS Mode Settings Press Enter Machine Password as mentioned above in the “Password Entry to Access Setup”.
  • Page 10 5.1. Press then to choose Parity Bits i.e. Even, Odd and No Parity. 5.2. Press to go back to the ‘MODBUS Setup’ . Press two times to choose ‘Stop Bits’ . 6.1. Press then to choose Stop Bits i.e. 1 or 2. 6.2.