  • Page 1 Use and Maintenance Manual Standing Extraction Arm ERGO LUX-M-R; ERGO LUX-K-R; ERGO LUX-L-R; ERGO LUX-D-R 10.01.2019 Standing Extraction Arm ERGO LUX-{M; K; L; D}-R...
  • Page 2: Table Of Contents

    Contents: Introductory Remarks ................ 3 Application ..................3 Reservations of Producer ..............3 Technical Data ................... 4 Structure and Function ..............9 Assembly and Start-up ................ 9 Operational Use .................. 10 Troubleshooting Guide................ 11 Maintenance ..................11 Occupational Health and Safety ............11 Transport and Storage ................
  • Page 3: Introductory Remarks

    1. Introductory Remarks The purpose of the present Use and Maintenance Manual is to supply the Purchaser and the future User with directions within the range of application , installation, start-up and the opera- tional use of the ERGO LUX-R Extraction Arm. Therefore, installing, start up and operational use are exclusively admissible after get- ting acquainted with the contents of the Use and Maintenance Manual.
  • Page 4: Technical Data

    G. Do not apply the device for conveying the air containing viscous compounds that would de- posit on the surface of the device elements. H. Do not apply the device for conveying the air containing aggressive compounds that would have destructive effect on the device elements. Maximum admissible vacuum in the system cannot exceed 800 Pa.
  • Page 5 Extraction arms type ERGO LUX-LL-R and ERGO LUX-DL-R are equipped with hoods with halogen spotlights. For information about the connection of the lighting see the Connection Diagram enclosed to the present Use and Maintenance Manual (see Fig. No.4). Table No.2 – Hoods for the ERGO LUX-R extraction arms Sort of the Material Type Weight...
  • Page 6 ERGO LUX-M-R WBN-125-K ERGO LUX-K-R steel sheet WBN-160-L ERGO LUX-L-R WBN-200-D ERGO LUX-D-R Fig. No.2 – Work ranges of the extraction arms Table No.5 – Dimensions of the work ranges of the extraction arms Type K [m] M [m] N [m]...
  • Page 7 4.1 – Flow charts of the ERGO LUX-R extraction arms 10.01.2019 Standing Extraction Arm ERGO LUX-{M; K; L; D}-R...
  • Page 8 CAUTION: The bent position of the arm – angle 45º in the middle joint Standing Extraction Arm ERGO LUX-{M; K; L; D}-R 10.01.2019...
  • Page 9: Structure And Function

    5. Structure and Function Structure of the ERGO LUX-R extraction arms is illustrated in Fig. No.1. They consist of sub- sequent elements: ● two arms (duct segments) connected with frictional joints, ● gas springs – to equilibrate the weight of the duct segments, ●...
  • Page 10: Operational Use

    START-UP: ● Prior to work, start the extraction fan and make sure the ventilation discharge ductwork is functioning. ● Set the hood into suitable position : not more than 30 cm from the welding arc, and not less than 20 cm – because the spatters might damage the hood and the suction stream could interrupt the protection gas shield (CO , argon).
  • Page 11: Troubleshooting Guide

    8. Troubleshooting Guide Table No.7 Problem Possible reason Corrective action 1. The extraction arm falls. Incorrectly adjusted Increase the tension upon joint frictional brake of the joint. frictional disks of the brake, within the joint by tightening the adjustment nuts. 2.
  • Page 12: Transport And Storage

    11. Transport and Storage Extraction arms ought to be stored and transported in partly assembled state and in special packages (designed for this purpose). During the transport and reloading protect the device from damage, scratching, indentations and pay attention that the markings would not get detached / obliterated. Store the extraction arms in dry rooms and areas of efficient ventilation.
  • Page 13 ASSEMBLY INSTRUCTION – EXTRACTION ARMS TYPE ERGO LUX-{M, K, L, D}-R Take out the ERGO LUX-R extraction arm from the transport package and put it stably on the even surface. Pull the arm segments apart to enable further assembly. Screw up the swivel support, to the plate of the lower joint – according to the information in Fig.
  • Page 14 Fig. No.6 – Assembly instruction of the extraction arms type ERGO LUX-{M;K;L;D}-R Photo No.1 – Wall bracket Standing Extraction Arm ERGO LUX-{M; K; L; D}-R 10.01.2019...
  • Page 15 Photo No.2 – Hood In case when the extraction arm is installed at the wall bracket, it is important to level the moun -ting plane of the wall bracket during its installing to the wall (see Photo No.1). If the bracket mounting plane is not horizontal, the extraction arm would tend to set (turn) itself always in the same position, and it is difficult to adjust the arm position.
  • Page 16: Sample Of The Declaration Of Conformity

    Declaration of conformity EC No. …………….. Manufacturer (eventually the authorized representative / importer): name: KLIMAWENT S.A. address: 81-571 Gdynia, Chwaszczyńska 194 A person, authorized for issuing the technical documentation: Teodor Świrbutowicz, KLIMAWENT S.A. hereby declares that the appliance: name: Standing Extraction Arm...
  • Page 17 NOTES: 10.01.2019 Standing Extraction Arm ERGO LUX-{M; K; L; D}-R...
  • Page 18 NOTES: Standing Extraction Arm ERGO LUX-{M; K; L; D}-R 10.01.2019...
  • Page 19 NOTES: 10.01.2019 Standing Extraction Arm ERGO LUX-{M; K; L; D}-R...
  • Page 20 Producer: KLIMAWENT S.A. 81-571 Gdynia, ul. Chwaszczyńska 194 tel. 058 629 64 80 fax 058 629 64 19 e-mail: klimawent@klimawent.com.pl www.klimawent.com.pl 810R80 ERGO LUX-M-1,5-R 10.01.2019/EN 810R81 ERGO LUX-M-2-R 10.01.2019/EN 810R82 ERGO LUX-K-2-R 10.01.2019/EN 810R83 ERGO LUX-K-3-R 10.01.2019/EN 810R84 ERGO LUX-L-2-R 10.01.2019/EN...

This manual is also suitable for:

Ergo lux-l-rErgo lux-k-rErgo lux-m-r

Table of Contents