Catalog Numbers 2198-DB111-F, 2198-DB127-F, 2198-DB310-F, 2198-DB324-F,
2198-DB335-F, 2198-DB356-F
Topic
Before You Begin
Install the AC Line Filter
Wire the AC Line Filter
AC Line Filter Dimensions
Additional Resources
This publication provides installation instructions for the AC line filters used with Kinetix® 5100
servo drives. Use these instructions for installing and wiring your AC line filter. For more
information on installing and wiring your AC line filter, see Kinetix 5100 Single-axis
EtherNet/IP™ Servo Drives Users Manual, publication 2198-UM004.
Before You Begin
For general guidelines when laying out your panel and mounting your AC line filter, refer to the
System Design for Control of Electrical Noise Reference Manual, publication GMC-RM001.
For guidelines specific to your application, refer to the Kinetix 5100 Single-axis EtherNet/IP
Servo Drives Users Manual, publication 2198-UM004.
ATTENTION: To avoid personal injury or damage to equipment due to hazardous voltages, follow
these guidelines when installing your AC line filter. NEC and local regulations always take
precedence.
Disconnect mains power before installation.
Verify that the rated voltage is compatible with the local supply voltage.
Connect the earth ground connection first when you make connections.
Page
1
2
2
4
7

Advertisement

Table of Contents
loading

Summary of Contents for Allen-Bradley Kinetix 5100 AC 2198-DB111-F

  • Page 1 Installation Instructions Original Instructions Kinetix 5100 AC Line Filter Catalog Numbers 2198-DB111-F, 2198-DB127-F, 2198-DB310-F, 2198-DB324-F, 2198-DB335-F, 2198-DB356-F Topic Page Before You Begin Install the AC Line Filter Wire the AC Line Filter AC Line Filter Dimensions Additional Resources This publication provides installation instructions for the AC line filters used with Kinetix® 5100 servo drives.
  • Page 2: Install The Ac Line Filter

    Kinetix 5100 AC Line Filter Install the AC Line Filter Mount the line filter to the cabinet panel with hardware as specified in this table. Torque Value Cat. No. Mounting Bolts N•m (lb•in) 2198-DB111-F 2198-DB127-F 2198-DB310-F M5 (#10-24) 1.6…2.0 (13.9…17.70) 2198-DB324-F 2198-DB335-F 2198-DB356-F...
  • Page 3 Kinetix 5100 AC Line Filter Wiring Examples for the AC Line Filter Circuit Protection Circuit 230V Protection Kinetix 5100 drive input L1’ power connections for L2’ 2198-DB -F Mains AC Input three-phase operation. L3’ AC Line Filter Load Line Bonded Cabinet Ground Bar Circuit Protection...
  • Page 4: Ac Line Filter Dimensions

    Kinetix 5100 AC Line Filter AC Line Filter Dimensions AC Line Filter Dimensions (Catalog numbers 2198-DB111-F and 2198-DB310-F) 30.0 (1.18) 20.0 (0.79) (0.22) 55.0 23.0 (2.17) (0.91) (0.22) 223.0 (8.78) Dimensions are in mm (in.). (0.26) (0.22) 54.0 54.0 72.0 (2.13) (2.13) (2.83)
  • Page 5 Kinetix 5100 AC Line Filter AC Line Filter Dimensions (Catalog numbers 2198-DB127-F and 2198-DB324-F) 29.1 (1.15) 86.0 28.0 (3.39) (1.15) (0.22) 263.0 (10.35) Dimensions are in mm (in.). (10.6) 109.0 76.0 76.0 (4.29) (2.99) (2.99) 263.0 (0.22) (0.22) (10.35) 275.0 (10.82) AC Line Filter Dimensions (Catalog number 2198-DB335-F) 33.0...
  • Page 6: Ac Line Filter Specifications

    Kinetix 5100 AC Line Filter AC Line Filter Dimensions (Catalog number 2198-DB356-F) 33.0 33.0 (1.30) (1.30) 80.0 28.0 28.0 (1.97) (1.10) (1.10) (0.22) 375.0 (0.22) (14.76) Dimensions are in mm (in.). 390.0 (15.35) 375.0 (14.76) 155.0 110.0 (6.10) (4.33) (0.22) AC Line Filter Specifications Leakage Current Rating...
  • Page 7: Additional Resources

    Kinetix 5100 AC Line Filter Additional Resources These documents contain additional information concerning related products from Rockwell Automation. Resource Description Provides product specifications for the Kinetix Integrated Kinetix Servo Drives Specifications Technical Data, Motion over EtherNet/IP network, Integrated Motion over publication KNX-TD003 Sercos interface, EtherNet/IP networking, and component...
  • Page 8: Rockwell Automation Support

    Rockwell Automation maintains current product environmental information on its website at http://www.rockwellautomation.com/rockwellautomation/about-us/sustainability-ethics/product-environmental-compliance.page. Allen-Bradley, Kinetix, Rockwell Automation, and Rockwell Software are trademarks of Rockwell Automation, Inc. EtherNet/IP is a trademark of ODVA, Inc. Trademarks not belonging to Rockwell Automation are property of their respective companies.