Download Print this page

Sealey G3 Series Instructions page 3

Air cut-off tool

Advertisement

4.
oPeratinG instructions
4.1
cHanGinG tHe cuttinG Disc
WarninG! Disconnect from the air supply before changing disc.
4.1.1
Use spanner to secure the shank and unscrew central hex screw with hex key.
4.1.2
remove the washer and old disc, place the new cutting disc onto the spindle.
4.1.3
replace the washer and secure with hex screw, but do not over tighten.
Check that replacement disc is not damaged (cracks, deformations or splinters etc).
Also check the mounting washer to ensure it is not deformed, burred or notched.
A damaged washer must not be used as it may cause irregular pressure on the disc which may cause
it to break. DO NOT tamper with a disc in order to adapt it to a different size holder.
4.2
oPeratinG
WarninG! Ensure you have read, understood and apply safety instructions.
4.2.1
Connect the tool to the air supply.
4.2.2
To start the tool, hold firmly and push the trigger locking lever forward whilst depressing
trigger.
4.2.3
The disc must be running at its maximum speed before attempting to cut the workpiece.
4.2.4
Slowly and smoothly bring the cutting disc toward the workpiece (avoid jerky movements).
4.2.5
Exert adequate pressure on the tool to allow cutting according to the type and size of the material you
are working with. Avoid subjecting disc to excessive strain, always hold tool firmly and ease disc
against workpiece (a harsh impact may break the disc). Maintain a controlled progression.
4.3
safety
4.3.1
The G3 Air Cut-Off Tool has improved features including:
4.3.2
360° rotating metal guard, to protect the user from shards/debris during cutting.
4.3.3
360° rotating exhaust, this allows the user to direct airflow away from the body/hands. This is located at
the base of the tool's handle
4.3.4
Variable air-valve, allows 4 different degrees of air pressure into the unit.
DO NOT allow tool to free run for an extended period of time as this will shorten its life.
5.
Maintenance
WarninG! Disconnect tool from air supply before changing accessories, servicing or performing
maintenance. replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be
dangerous and will invalidate the warranty.
5.1
If the air supply does not include an oiler, lubricate the air tool daily with a few drops of Sealey air tool oil
dripped into the air inlet to prolong its life.
5.2
Clean the tool after use.
5.3
loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type of hose
connectors. To remedy check the air supply and follow instructions in
chapter 3.
b) Grit or gum deposits in the tool may also reduce performance. If your model has an air strainer
(located in the area of the air inlet), remove the strainer and clean it. Flush the tool out with gum
solvent oil or an equal mixture of SAE No 10 oil and paraffin. Allow to dry before use.
5.4
For a full service contact your local Sealey service agent.
5.5
When not in use, disconnect from air supply, clean tool and store in a safe, dry,
childproof location.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
iMPortant: No liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
inforMation: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
sole uK Distributor, sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7Ar
Original Language Version
www.sealey.co.uk
01284 757500
Web
sales@sealey.co.uk
01284 703534
email
GSA25
Issue: 3 - 10/11/10

Advertisement

loading

This manual is also suitable for:

Gsa25