DATASHEET UP UNIPO 2TT0901CAN02C OTHER SYMBOLS: RGB ELEKTRONIKA AGACIAK CIACIEK SPÓŁKA JAWNA Jana Dlugosza 2-6 Street 51-162 Wrocław www.rgbelektronika.pl Poland biuro@rgbelektronika.pl +48 71 325 15 05 www.rgbautomatyka.pl www.rgbautomatyka.pl www.rgbelektronika.pl...
Page 2
YOUR PARTNER IN MAINTENANCE Repair this product with RGB ELEKTRONIKA ORDER A DIAGNOSIS LINEAR ENCODERS SYSTEMS INDUSTRIAL COMPUTERS ENCODERS CONTROLS SERVO AMPLIFIERS MOTORS MACHINES OUR SERVICES POWER SUPPLIERS OPERATOR SERVO PANELS DRIVERS At our premises in Wrocław, we have a fully equipped servicing facility. Here we perform all the repair works and test each later sold unit.
Universal unipo® Flat Panel UFP 1 General ..........................7 1.1 Information on operating instructions ................7 1.2 Explanation of symbols ....................7 1.3 Liability and warranty...................... 8 1.4 Quality assurance......................8 1.5 Copyright ........................8 1.6 Spare parts........................10 1.7 Disassembly ......................... 10 1.8 Waste disposal ......................
Page 6
Universal unipo® Flat Panel UFP 4.2.7 Front plate ......................23 4.2.8 Conversion kit......................23 4.3 Technical data ......................24 4.3.1 Optical data of the different UFP ................25 4.3.2 Display measurements of the different UFP............26 4.3.3 Ambient conditions during operation ..............27 4.3.4 Electric safety ......................
Page 7
Universal unipo® Flat Panel UFP 6.6.7 Adjusting vertical image position - VERT. POSITION ......... 54 6.6.8 Miscellaneous settings - MISC. SETTINGS............56 6.6.8.1 Setting colors - Colors ................... 57 6.6.8.2 Adjust the contrast - Contrast............... 58 6.6.8.3 Adjusting the black level – RGB Offset............59 6.6.8.4 Setting the write protection - Write Prot.
Page 8
Universal unipo® Flat Panel UFP 12 List of tables........................87 13 List of figures ........................89 14 Index..........................91 Revision status 19.01.2010...
Universal unipo® Flat Panel UFP General 1 General 1.1 Information on operating instructions These operating instructions describe the installation, operation and maintenance of the equipment. Compliance with all specified safety notes and instructions for use is mandatory for safe working and proper handling of the device.
We reserve the right for technical modifications to the product with the aim of improving the utilization properties and further development. 1.4 Quality assurance The quality assurance system of unipo GmbH has been certified acc. to DIN EN ISO 9001:2000. 1.5 Copyright These operating instructions is to be treated confidentially.
Page 11
® unipo is a protected trademark of the unipo GmbH. Any other brand or product names, if registered as trademarks, which may be mentioned as reference, remain protected by the industrial property rights of the corresponding owner, are not affected by this and fully recognized.
Universal unipo® Flat Panel UFP General 1.6 Spare parts ATTENTION! Danger of damage to the device! Wrong or faulty spare parts can cause damage, malfunction or even total failure of the device! Only use original spare parts from the manufacturer.
® Technical enquiries should be addressed to the unipo Service Department. This department is available to you at any time under the fallowing phone number: unipo GmbH Pelarstraße 21...
Page 14
Universal unipo® Flat Panel UFP General Revision status 19.01.2010...
Universal unipo® Flat Panel UFP Safety 2 Safety This paragraph provides you with an overview of all important safety aspects for optimal protection of personnel as well as safe and trouble-free operation of the device. The individual chapters additionally contain concrete safety notes, which are highlighted with symbols, for averting immediate dangers.
Universal unipo® Flat Panel UFP Safety 2.3 Intended use Equipment safety and reliability is only guaranteed if used as intended in accordance with the information in the operating manual. The UFP serves the visualization of processes and data (visual display units and control panels) and is a replacement for old tube type display units It is universally used on machines and plants.
Universal unipo® Flat Panel UFP Safety 2.6 System control The device is used in an overall plant system and serves the visualization of processes and data. The customer must make sure that the device is connected to the system control in agreement with the applicable accident prevention regulations.
Universal unipo® Flat Panel UFP Transport, packing and storage 3 Transport, packing and storage 3.1 Transport inspection Check delivery immediately on receipt for completeness and transport damage. Do not accept delivery or only accept under proviso if there is externally recognizable transport damage.
Universal unipo® Flat Panel UFP Transport, packing and storage 3.3 Storage After unloading, the packing units must be stored up to time of assembly in compliance with the attached shipping labels. Packed machine parts and accessories must not be unpacked.
Here the signals are digitized, processed and transferred to the display unit for on-screen display. ® Signal processing is accomplished by the unipo video FPGA. With the optional control unit the image can individually changed (e.g. contrast, size, position, brightness).
Universal unipo® Flat Panel UFP Design of the UFP 4.2 Scope of delivery The scope of delivery includes • UFP (display unit, electronics unit, power supply module, input module) • Mains cable • Test certificate • Technical information on input module •...
Universal unipo® Flat Panel UFP Design of the UFP 4.2.1 Design of the UFP Fig. 1: UFP front view Fig. 2: UFP rear view The UFP consists of the following modules Display unit Power supply module Control unit (optional) Input module (I-Module)
The display unit has the function of visualizing the processes. It is a TFT flat screen and replaces the old tube display of the original monitor. ® Connection to the electronic unit is accomplished through the unipo video bus. UFP Device Tube display of original monitor 6"...
The electronic unit serves the function of digitizing and processing the video signals and ® contains the central interface to the display unit, the unipo videobus It can be mounted directly to the display, or placed remotely via an up to 5m ribbon cable.
Sync. to green, VGA, and others Special features • meets the requirements of video workstations ® • plug&play setting in connection with the unipo input modules • 16 user specific image settings can be stored • up to 128 image formats in supplied library •...
Universal unipo® Flat Panel UFP Design of the UFP 4.3.1 Optical data of the different UFP Model Resolution Viewing angle Contrast ratio Brightness Pixels 640 x 480 ± 50° / -45° +35° typ. 300:1 typ. 350 cd/m 6" 640 x 480 ±...
Universal unipo® Flat Panel UFP Design of the UFP 4.3.2 Display measurements of the different UFP Fig. 3: The UFP-family Display measurements Model Image size Electronic unit (mm) W x H x D (mm) W x H x D (mm)
Universal unipo® Flat Panel UFP Design of the UFP 4.3.3 Ambient conditions during operation Designation Technical data Test acc. to IEC 68-2-1 (Test Ab), IEC 68-2-2 (Test Bb), IEC 68-2-14 (Test Nb) Test conditions Device ready for operation and switched on...
Page 30
Universal unipo® Flat Panel UFP Design of the UFP Revision status 19.01.2010...
Universal unipo® Flat Panel UFP Installation and start-up 5 Installation and start-up WARNING! Danger of injury! Installation and assembly work may only be carried out by trained technical staff while observing the safety instructions. 5.1 Measures before installation Before installation, make sure that the machine is device is complete and that there are no deformations, scratches or other damage which could indicate a fall having occurred.
Universal unipo® Flat Panel UFP Installation and start-up 5.1.1 Measures for compliance with the electromagnetic compatibility (EMC) This device complies with the basic European standards EN 50081-2 for interference transmission in industrial applications, as well as EN 50082-2 for interference immunity in industrial applications, as long as these installation instructions have been adhered to: •...
Page 33
Universal unipo® Flat Panel UFP Installation and start-up • Route lines, which belong together by signal (e. g. feed and return lines), either with very little distance from each other, or twist them together. • Route wanted signal lines and the associated lines for equipotential bonding close together and keep these cables as short as possible.
Universal unipo® Flat Panel UFP Installation and start-up 5.2 Installation The installation of the UFP depends on the following factors: • chosen optional accessories Optional accessories are delivered with detailed installation instructions. These operating instructions describe the installation of the UFP by means of front plate and clamping claws.
Universal unipo® Flat Panel UFP Installation and start-up 5.2.2 Fastening of the UFP on the optional front plate by means of clamping claws Special clamping claws for fastening the UFP to the front plate are available. Assembly of the clamping claws: Turn screw 1 into clamping claw 2.
Universal unipo® Flat Panel UFP Installation and start-up 5.3 Connections 5.3.1 Video connection The devices of the UFP-family can be connected to various video sources via corresponding input modules. These include analog (e.g. VGA or BAS) as well as digital (e.g. EGA) input signals: •...
Universal unipo® Flat Panel UFP Installation and start-up 5.3.2 AC - Version The UFP can be connected to the 84 V – 264 V voltage supply by means of an inlet connector for non-heating appliances. The UFP has no additional On/Off-switch.
Universal unipo® Flat Panel UFP Installation and start-up 5.4 Start-up 5.4.1 Measures before starting the UFP Please observe before starting the device: • Check all previously loosened screw connections for tight fit. • Check all previously loosened plug/cable connections for tight fit.
Universal unipo® Flat Panel UFP Software description 6 Software description This description applies for UFP-units with firmware version 06/04/00 or higher. The version number appears in the On-Screen-Display when booting or can be interrogated via the menu (GLOBAL SETTINGS / Version).
Universal unipo® Flat Panel UFP Software description 6.3 Manual configuration of parameters Each menu can be individually edited via a cable linked control unit. 6.3.1 The control unit The control unit consists of the following elements: Fig. 7: Control unit Function key ESC (Escape) Navigation key [►]...
Universal unipo® Flat Panel UFP Software description Symbol Function Explanation Escape To exit the menu without saving ► Navigation key right To navigate in the menu and to set parameters (right) ◄ Navigation key left To navigate in the menu...
Universal unipo® Flat Panel UFP Software description 6.4 Manual configuration with control unit The keys on the control unit are used as follows: • From ongoing operation the function key [ ] is used to open the menu structure, starting with the main menu SELECT.
Universal unipo® Flat Panel UFP Software description 6.5 UFP menu structure Main menu Sub-menu Description SELECT To select a pre-determined format, Auto-Setup SAMPLE RATE To set the sample rate PHASE To set the phase angle HORZ. EXPANSION To set the horizontal image size HORZ.
Universal unipo® Flat Panel UFP Software description Main menu Sub-menu Description GLOBAL SETTINGS SOG Threshold To set the threshold for the Sync-separation Version Information to the UFP version (not editable) Environment Operating status Restore To reset the device to its...
Universal unipo® Flat Panel UFP Software description 6.6.1 Manually setting the pre-defined format - SELECT The first selection window is the menu SELECT. The currently valid parameters are displayed. Select ► Sinumerik xy 60.0 Hz 15.6kHz 21.0 MHz Fig. 8: Menu sELECT From this menu an existing format can be selected or a new calculation can be automatically made.
Page 46
Universal unipo® Flat Panel UFP Software description NOTE The associated settings are always loaded directly, so that the event can be checked immediately. The format selected last will be displayed. Vertical, horizontal and pixel frequencies will be displayed as additional information.
Universal unipo® Flat Panel UFP Software description 6.6.2 Setting the sample rate - SAMPLE RATE The next selection window is the SAMPLE RATE menu. The currently valid parameter is displayed. SAMPLE RATE ► (25.0 MHz) Fig. 10: Menu SAMPLE RATE Here you can set the frequency of video signal digitizing per line.
Page 48
Universal unipo® Flat Panel UFP Software description NOTE Each video module generates in each line an exactly specified number of pixels. For an exact display both values must match exactly. The specified value does not correspond with the horizontal resolution, but is always higher.
Universal unipo® Flat Panel UFP Software description 6.6.3 Adjust the phase angle - PHASE The next selection window is the menu PHASE. The currently valid parameter is displayed. PHASE ► 123° Fig. 12: Menu PHASE Here the phase angle can be set.
Universal unipo® Flat Panel UFP Software description 6.6.4 Adjust horizontal image size - HORZ. EXPANSION The next selection window is the menu HORZ. EXPANSION. The currently valid parameter is displayed. HORZ. EXPANSION ► (interpolated) Fig. 14: Menu HORZ EXPANSION Here the horizontal expansion factor can be set.
Page 51
Universal unipo® Flat Panel UFP Software description NOTE The properties not expanded, interpolated and duplicated of the factor are not separately adjustable. Some factors are only available as duplicated. NOTE For some UFP-models under the setting 1:1 there is the additional factor 8:9 (elimin.
Universal unipo® Flat Panel UFP Software description 6.6.5 Adjust horizontal image size - HORZ. POSITION The next selection window is the menu HORZ. POSITION. The currently valid parameter is displayed. HORZ. POSITION ► Fig. 16: Menu HORZ POSITION Here the horizontal image position can be adjusted.
Page 53
Universal unipo® Flat Panel UFP Software description NOTE The value suggested by [F] is not always exact. If required, the value must be manually adjusted. NOTE The area read in by the input signal is adjusted; not the image position that appears in the display.
Universal unipo® Flat Panel UFP Software description 6.6.6 Adjusting horizontal image size - VERT. EXPANSION The next selection window is the menu VERT. EXPANSION. The currently valid parameter is displayed. VERT. EXPANSION ► 13:8 (interpolated) Fig. 18: Menu VERT EXPANSION Here the vertical expansion factor can be set.
Page 55
Universal unipo® Flat Panel UFP Software description NOTE The properties not expanded, interpolated and duplicated of the factor are not separately adjustable. Some factors are only available as duplicated. Revision status 19.01.2010...
Universal unipo® Flat Panel UFP Software description 6.6.7 Adjusting vertical image position - VERT. POSITION The next selection window is the menu VERT. POSITION. The currently valid parameter is displayed. VERT. POSITION ► Fig. 20: Menu VERT POSITION Here the vertical image position can be adjusted.
Page 57
Universal unipo® Flat Panel UFP Software description NOTE The value suggested by [F] is not always exact. If required, the value must be manually adjusted. NOTE The area read in by the input signal is adjusted, but not the image position that appears in the display.
Universal unipo® Flat Panel UFP Software description 6.6.8 Miscellaneous settings - MISC. SETTINGS The next selection window is the menu MISC. SETTINGS. This menu window contains adjustment possibilities which normally do not need to be adjusted. The structure is slightly different, because it has additional sub-menus. For reasons of clarity all sub-menus are shown here.
Universal unipo® Flat Panel UFP Software description 6.6.8.1 Setting colors - Colors The first selection window under MISC. SETTINGS is the menu Colors. This is where the setting of colors takes place. The currently valid parameter is displayed. • Press key [ ] to open the menu Colors.
Universal unipo® Flat Panel UFP Software description 6.6.8.2 Adjust the contrast - Contrast The next selection window under MISC. SETTINGS is the menu Contrast. Here the amplification of the video signal is adjusted. The currently valid parameter is displayed. •...
Universal unipo® Flat Panel UFP Software description 6.6.8.3 Adjusting the black level – RGB Offset The next selection window under MISC. SETTINGS is the menu RGB Offset. This sub-menu is used to adjust the black level (RGB). The currently valid parameter is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.8.4 Setting the write protection - Write Prot. The next selection window under MISC. SETTINGS is the menu Write prot.. Here the write protection for the formats is set. MISC. SETTINGS Write prot.: Enabled Fig.
Universal unipo® Flat Panel UFP Software description 6.6.8.5 Calling up format information - Format info The next selection window under MISC. SETTINGS is the menu Format info. Here a short information about the currently detected input signal is displayed. The currently valid parameters are displayed.
Universal unipo® Flat Panel UFP Software description 6.6.9 Editing the format name - NAME The next selection window is the menu NAME. Here you can assign a new format name. The currently valid format name from the library is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.10 Global device settings – GLOBAL SETTINGS The next selection window is the GLOBAL SETTINGS menu. This menu window contains adjustment options, which are not just limited to individual formats, but have effect for the entire device.
Universal unipo® Flat Panel UFP Software description 6.6.10.1 Setting the brightness of the image – Brightness The first selection window under GLOBAL SETTINGS is the menu Brightness. This menu is used to set the brightness of the background illumination. The currently valid parameter is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.10.2 Setting the screensaver – ScrSaver The next selection window under GLOBAL SETTINGS is the menu ScrSaver. This sub-menu is used to adjust the screensaver. The currently valid parameter is displayed. • Press key [ ] to open the menu ScrSaver.
Universal unipo® Flat Panel UFP Software description 6.6.10.3 Setting the sensitivity – Sensitivity The next selection window under GLOBAL SETTINGS is the menu Sensitivity. This sub-menu is used to set the sensitivity for distinguishing between formats. The currently valid parameter is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.10.4 Filtering Sync-Signals – Sync Filter The next selection window under GLOBAL SETTINGS is the menu SyncFilter. It is used to apply an additional filtering of the Sync–Signals. The currently valid parameter is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.10.5 Sync-separation – SOG Threshold The next selection window under GLOBAL SETTINGS is the menu SOG Threshold. The currently valid parameter is displayed. • Press key [ ] to open the menu SOG Threshold.
Universal unipo® Flat Panel UFP Software description 6.6.10.6 Showing the UFP version – Version The next selection window under GLOBAL SETTINGS is the menu Version. It shows various information on the UFP version status. The currently valid parameter is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.10.7 Showing the operating status of the device – Environment The next selection window under GLOBAL SETTINGS is the menu Environment. It shows the current operating status of the UFP. The currently valid parameter is displayed.
Universal unipo® Flat Panel UFP Software description 6.6.10.8 Resetting the device – Restore The next selection window under GLOBAL SETTINGS is the menu Restore. The default settings of the UFP are reloaded and the user library is deleted. • Press key [ ] to open the menu Restore.
After entering the correct key code you have access to an extended menu. WARNING! This menu has exclusively been provided for service purposes. Changes must only be made by personnel from unipo GmbH. The key code is therefore not passed on to the customer. Revision status 19.01.2010...
Universal unipo® Flat Panel UFP Software description 6.6.11 Quitting and exiting the menu / saving – EXIT The next selection window is the menu EXIT. This completes the process and exits the menu. • Press key [ ] to open the menu EXIT.
Universal unipo® Flat Panel UFP Maintenance 7 Maintenance 7.1 Safety WARNING! In principle, work on the device must only be carried out by qualified personnel trained especially for this type of work. WARNING! Danger from electric current! Work on electrical systems may only be carried out by professional electricians while observing the safety regulations.
If the UFP is continuously used, the fan must be replaced at the latest after 2 years (or approx. 20.000 operating hours). The new fan is delivered with replacement instructions. ® With the following data the fan can be directly ordered from unipo Name DC-Fan 12V Spare parts number FLL012D15010 7.3 Measures after maintenance work...
Universal unipo® Flat Panel UFP Malfunctions 8 Malfunctions Faults on electric installations and on mechanical components must only be rectified by specially trained expert personnel. In case of faults that cannot be rectified with the measures described hereunder, you should consult the manufacturer or a service partner authorized by the manufacturer.
Universal unipo® Flat Panel UFP Malfunctions 8.3 Faults – image quality With a perfect image the UFP displays all details without flickering and interferences, right to the edges of the screen. The screen is completely filled without any black margins. Colour appear clearly and with high contrast.
Universal unipo® Flat Panel UFP Malfunctions Fault Cause Remedy Menu Ghost images/ Video cable defective Replace the video reflections or of poor quality cable Incorrect color setting Reduce the number of GLOBAL colors to 64 (other SETTINGS Colors setting) Incorrect phase angle...
Allow the device to cool down to ambient temperature before starting work. Exclusion of warranty After operations and changes to the device, which were not made by unipo GmbH, the warranty for the device will become null and void! unipo GmbH will not assume liability for damage to persons or property resulting from unauthorized operations to the device! Revision status 19.01.2010...
Universal unipo® Flat Panel UFP Glossary 10 Glossary Designation Explanation Flat panel Flat screen FPGA Abbreviation for Field Programmable Gate Array Free programmable Logic-Modules, which can be linked to form complex circuitries Currently taking over the function of micro-processors MTBF Mean Time Between Failure the mean time between two failures;...
Universal unipo® Flat Panel UFP Appendix – Technical data sheets 11 Appendix – Technical data sheets The following additional data sheet is attached to these operating instructions. Technical information Brief instructions status 30/01/06 UFP input module 7LPIP9270200 These instructions are up-to-date at the time of delivery but are subject to changes, based on variation of components.
Page 88
Universal unipo® Flat Panel UFP Appendix – Technical data sheets Revision status 19.01.2010...
Universal unipo® Flat Panel UFP List of figures 13 List of figures Fig. 1: UFP front view ......................21 Fig. 2: UFP rear view ......................21 Fig. 3: The UFP-family......................26 Fig. 4: Assembly of clamping claws 1..................33 Fig. 5: Assembly of clamping claws 2..................33 Fig.
Page 92
Universal unipo® Flat Panel UFP List of figures Fig. 32: Menu Brightness ....................64 Fig. 33: Menu ScrSaver....................... 65 Fig. 34: Menu Sensitivity ....................66 Fig. 35: Menu Sync Filter ....................67 Fig. 36: Menu SOG Threshold .................... 68 Fig. 37: Menu Version ......................69 Fig.
Need help?
Do you have a question about the UFP 6" and is the answer not in the manual?
Questions and answers