ALRM-MS-1/ALRM-MS-2
Thank you for purchasing our product. Please read this manual carefully before you use it. This manual covers
the ALRM-MS-1 and ALRM-MS-2 products.
NOTE! The manufacturer reserves the right to alter the device parameters and operating methods without a
prior notice. Due to continuous modifications, some of the functions described in this manual may slightly
differ from reality. The author reserves the right to amend the information contained herein in full or in part
without a prior notice.
Basic information
Wireless passive PIR motion detector, which uses an advanced digital signal analysis including automatic
temperature compensation. The detector can remotely link with an alarm system panel and send signals upon
detecting human body temperature in the sensing range. The device is stable and features a low power
consumption.
Features
• Low power consumption
• Automatic temperature compensation
• EMC interference protection
• Protection against interference caused by a visible bright light.
SPECIFICATION
• The device analyses digital signals sent by two sensors
• Power consumption at standby: ≤30uA
• Power consumption during operation: ≤13mA
• Detection range: 8m
• Detection angle: 110°
• Communication frequency: 433.92MHz
• Range in open space:
- Version with external antenna: ≥450m
- Version with internal antenna: ≥300m
• Supply DC voltage: 6V DC6V(4 x 1.5/AAA battery)
• Operating temperature: -10° ~ 40°
• Recommended installation height: 2 to 2.5m
• Dimensions (L*W*H): 100x56.5x44.5mm
Instrukcja obsługi czujnika ruchu

Advertisement

loading

Summary of Contents for 8level ALRM-MS-1

  • Page 1 Instrukcja obsługi czujnika ruchu Thank you for purchasing our product. Please read this manual carefully before you use it. This manual covers the ALRM-MS-1 and ALRM-MS-2 products. NOTE! The manufacturer reserves the right to alter the device parameters and operating methods without a prior notice.
  • Page 2 Activating the detector Scanning sensitivity switch H – fast analysis in normal conditions (default setting) M – more accurate analysis, used in case of EMC interference Once the batteries are installed, the detector sends an activation signal. After the signal is sent, the detector L –...