To set up your PEAK
Economizer controller, perform the
®
following steps:
1.
Install the controller assembly with the included
installation instructions. Refer to the PEAK Economizer
Basic Model Product Data and Installation Guide
(LIT-12013281).
2.
Install additional sensors. The factory installs the
damper actuator and outdoor air sensor. You must
install any other sensors and output connections.
3.
Configure the controller using the local display.
4.
Run a Self-Test to verify proper operation.

Mounting the controller on a DIN rail

1.
Horizontally mount a 20 cm (8 in.) section of 35 mm
(1.3 in.) DIN rail.
2.
On the back of the controller, pull the two bottom
mounting clips outward (down).
Figure 1: Pull down lower mounting clips
PEAK Economizer Basic Model Quick Start
3.
4.
Figure 2: Push up lower mounting clips

Wiring

1.
2.
3.
4.
Place the controller on the DIN rail.
Push the bottom mounting clips inward (up) to
secure the controller on the DIN rail.
Connect the sensors to the inputs on the Economizer
controller.
Use spade connectors to terminate the inputs and
outputs with the Spade termination.
Note: Temperature inputs accept a 10k
thermistor type 2 sensor. Humidity inputs
accept a 0 VDC to 10 VDC sensor.
Use the Economizer wiring harness to connect the I/
O with the pin connector termination type.
Install the sensors in the appropriate air stream.
*241014302090—*
Guide
24-10143-02090 Rev —
2019-08-28
(barcode for factory use only)
PK-ECO1001-0

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Economizer Basic and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Peak Economizer Basic

  • Page 1 PEAK Economizer Basic Model Quick Start Guide 24-10143-02090 Rev — 2019-08-28 Overview Place the controller on the DIN rail. Push the bottom mounting clips inward (up) to To set up your PEAK Economizer controller, perform the ® secure the controller on the DIN rail.
  • Page 2 Table 1: Rooftop unit wiring example Callout Description Callout Description Wiring harnesses Rooftop unit control board CD-W00-00-2 zone CO sensor Conventional thermostat 24 VAC coil of exhaust fan or ERV relay or contactor M9205-GGA-EC01 actuator PEAK Economizer Basic Model Quick Start Guide...
  • Page 3 Table 2: Heat pump wiring example Callout Description Callout Description Wiring harnesses Heat pump control board CD-W00-00-2 zone CO sensor Conventional thermostat 24 VAC coil of exhaust fan or ERV relay or contactor M9205-GGA-EC01 actuator PEAK Economizer Basic Model Quick Start Guide...
  • Page 4 SA Bus (green) After approximately 10 seconds: Y2 Status 24 VAC • Blink: Normal communication Connector • On steady: Communication lost W1 Status or O/B Status 24 VAC Connector Shutdown Status 24 VAC Connector PEAK Economizer Basic Model Quick Start Guide...
  • Page 5 Compressor 2 Displays the compressor stage 2 Exhaust Setup None None, Non- command. modulating Control Y1-Tstat Displays the thermostat Y1 status. Damper % Fan On 0% to 100% Y2-Tstat Displays the thermostat Y2 status. PEAK Economizer Basic Model Quick Start Guide...
  • Page 6 Compressor 2 Off that the device uses. Power Default value: IP Exhaust Test Relearn System Relearns the sensors True, False Damper Test Ramp connected to the Open; controller. Default Ramp value: False Close PEAK Economizer Basic Model Quick Start Guide...
  • Page 7 UL Listed, File E107041, UL 916, Energy Management Equipment FCC Compliant to Part 15, Class B Canada: cUL Listed, File E107041, CSA 22.2 No. 236, Signal Equipment Industry Canada, Industry Canada Compliant - ICES-003 PEAK Economizer Basic Model Quick Start Guide...
  • Page 8 North American Emissions Compliance United States This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.