artisan I-2400 Manual To Operations

Digital incubator shaker

Advertisement

Quick Links

artisan I-2400 Manual To Operations

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the I-2400 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for artisan I-2400

  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 NEW BRUNSWICK SCIENTIFIC CO., INC. BOX 4005 • 44 TALMADGE ROAD • EDISON, NJ 08818-4005 Telephone: 1-732-287-1200 • 1-800-631-5417 Fax: 732-287-4222 • Telex: 4753012 NBSCO Internet: http://www.nbsc.com • E-mail: bioinfo@nbsc.com Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 4 P.R. China P.R. China Tel: 21 6481 2658 Tel: 10 6371 0167 Fax: 21 6481 2665 Fax: 10 6374 1107 E-mail: nbschc@online.sh.cn New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 5 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 6 If operational guidelines are not followed, equipment damage and personal injury can occur. Please read the entire User’s Guide before attempting to use this unit. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 8 WARNING ! Bold Text in bold face type emphasizes key words or phrases. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 9 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 10 Any tampering or alteration of the electronic clock will void the 10,000 hour warranty. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 11 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 12: Table Of Contents

    EPLACING THE EMPERATURE ONTROL OARD 5.11 ...............33 NSTALLING THE UICK HANGE LATFORM PTION 5.12 .................34 ASSING ANIFOLD ETROFIT NSTALLATION APPENDIX .............................. 37 New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 13 Accessory Flask Clamps......................40 6.4.3 Clamp Mounting Hardware Kits....................41 DRAWINGS............................. 43 ..........................43 ONTROL CHEMATICS ..........................44 IST OF LLUSTRATIONS INDEX ..............................45 I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 14: Introduction

    I-2400. The manual is divided into four basic sections. Chapters 1-2 provide an overview of your I-2400 and all of its features and options. Chapters 3-4 detail the set-up and operation of the instrument. Chapter 5 outlines maintenance and service procedures which should be utilized only by a qualified service engineer, as well as routine maintenance for your use.
  • Page 15 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 16: Overview

    The shaker may be operated either continuously, or in a timed mode via a programmable timer for shaking periods of 0.1 hour to 99.9 hours. The I-2400 is equipped with audible and visible alarms which are activated when an alarm condition exists, as follows: •...
  • Page 17: Control Panel

    A general description of the display, the user interface keys and the indicator lights follows. For operation of the control panel, see Section 4. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 18: Led Display

    This key is used to start or stop the shaking motion. It will also activate or stop the timer when a timed run is desired. SELECT This key is used to change the displayed parameter. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 19: Status Indicator Lights

    Figure 2). They indicate the current parameter being displayed: • RPM: revolutions per minute • Hours: time remaining • °C: temperature (in degrees Celsius) I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 20: Platform Assemblies

    Platform Assemblies The I-2400 can be used with a wide variety of NBS 18 inch x 18 inch (46 cm x 46 cm) platforms, which will accept a variety of clamps for flasks and test tubes (see Section 6.4.2). Available Options These options can be ordered for factory installation, or for field retrofit by an NBS authorized technician (see Section 6.4 for part numbers).
  • Page 21: Bearings

    2.5.3 Motor The I-2400 Shaker uses a 3-phase brushless ball bearing DC motor. This low profile motor provides high torque along with quiet, efficient operation and low maintenance. The motor has a rating of 1/15 horsepower.
  • Page 22 • Rectification and regulation for analog power supplies • Provides signal conditioning circuitry and A/D conversion for the RTD- based temperature measurement • Controls the heater. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 23 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 24: Installation

    The I-2400 is a versatile instrument that can be operated in a continuous fashion or set for a timed run. The following section describes set-up and installation procedures. Unpacking and Inspection Upon unpacking the unit, inspect it carefully for any damage that may have occurred during transit.
  • Page 25: Hose Connections

    If the unit is using tap water as the coolant, it is preferable that the supply hose be attached to a supply valve, to minimize water use. Figure 4: Space Requirements I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 26: Electrical Connections

    If the Quick Change Option is installed: 1. Slip the platform between the side guides and push the platform to the rear retainer. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 27: Flask Clamp Installation

    PLATFORM CLAMP BODY LOWER (LEGS AND BASE) GIRDLE WITH GIRDLE TUBES NOTE: 2800 ml Fernbach Flask Clamp is applicable to the above. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 28 S2117-3050 all stainless steel flat slotted (-) head screw platforms NOTE: 2800 ml Fernbach Flask Clamps are applicable to the above chart. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 29 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 30: Operation

    4. Set the speed by using the ∆ or ∇ keys until the desired setpoint is displayed. NOTE: Holding the ∆ or ∇key down will cause the setting to change more rapidly: New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 31: Checking Setpoints

    To stop the alarm: Press the SELECT key and change to any other function. To cancel the timer without stopping the shaker: 1. Repeat steps 1 and 2. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 32: Alarm Functions

    2. While the set LED is lit press the START/STOP key. The Time indicator will go out and the display will read “OFF”. Alarm Functions I-2400 has an audible alarm which is activated at predetermined times. It may be deactivated in the following way: 1. Press SELECT to light HRS.
  • Page 33: Temperature Offset Calibration

    2. Simultaneously press the ∆ and ∇ keys. The SET and MAINT indicators will light. 3. While the SET and MAINT indicators are illuminated, press the START/STOP key. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 34: Total Running Time

    Total Running Time The control module of the I-2400 totals the time the shaker has been “ON” to track hours of usage. To display the accumulated running time: 1. Select HRS using the Select key. 2. Simultaneously press the ∆ and ∇ keys.
  • Page 35 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 36: Service & Maintenance

    To avoid damage to your unit, we recommend the use of NBS door/lid polish (P0860- 0949). New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 37: Changing Fuses

    2. Lay the unit on its left side, using a soft pad to protect the finish. 3. Remove the bottom cover using a Phillips head (+) screwdriver. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 38: Replacing The Motor Assembly

    1. Turn off the power and unplug the power cord. 2. Lay the unit on its left side using a soft pad to protect the finish. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 39: Motor Assembly Replacement

    16. Connect the power cord and turn the circuit breaker to the ON position. The unit is ready for operation. Figure 7: Motor Assembly Replacement I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 40: Maint Indicator On

    Cooling Coil Kit Retrofit Installation The cooling coil option provides the ability to control below ambient temperatures in the I-2400. Control can be maintained at a temperature 5°C or more above the coolant temperature. The Cooling Coil Kit (NBS #M1192-9902) should contain the following items:...
  • Page 41: Cooling Coil Installation

    Be careful not to scratch the paint. 8. Install the two grommets supplied in the kit in the two holes where the plugs had been (see Figure 8b). I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 42: Cooling Coil Installation

    17. Slide a hose clamp over each hose and slip each clamp to within 1/8 inch to 3/16 inch from the end of the hose. Tighten the clamps securely and check for leaks. 18. Reassemble unit in reverse order. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 43: Esd Precautions

    (two screws on the sides and three screws on the bottom). Allow the front panel to lay on its face, on the cloth or cardboard. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 44: Control Board Replacement

    8. Lift the board out of the front panel and disconnect the keypad connector from J4. NOTE: Be careful not to lose the five ¼ inch spacers or the gray insulator. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 45: Replacing The Temperature Control Board

    (keys mate and no pins remain exposed). 10. Replace the front panel, securing it with the five screws. 11. Plug in the power cord. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 46: Installing The Quick Change Platform Option

    NOTE: Recommended for speeds up to 400 RPM. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 47: Gassing Manifold Retrofit Installation

    3. Use a sharp tool to pierce through the insulation under the three exposed holes. Figure 10: Gassing Manifold Kit Installation (Top View) I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 48 Internal tubing, caps, etc. are to be supplied by the Customer as required. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 49 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 50: Appendix

    Can be deactivated for continuous operation. • Additionally, unit will display total accumulated running time for service information. OPERATING AMBIENT ENVIRONMENT 0° - 40°C, 90% humidity, non-condensing. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 51: Available Platforms

    The kit does not include a platform. Once installed, a speed of 25-400 rpm is recommended. The package should be installed by a qualified Service Engineer. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 52: Interchangeable Platforms

    Main Control Board Kit M1192-7000 Temperature Control Board M1190-5000 Membrane Switch Panel P0400-4330 10 Amp Circuit Breaker P0400-3011 10 Amp Solid State Relay P0400-2751 Relay New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 53: Accessories

    ACSB-500S 500 ml Media Bottle Clamp ACSB-1000S 1.0L Media Bottle Clamp All of the clamps listed above are constructed of stainless steel. I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 54: Clamp Mounting Hardware Kits

    See the tables in Section 3.7 to identify the proper screws for your shaker application by reference to the head style. New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 55 THIS PAGE INTENTIONALLY BLANK I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 56: Drawings

    Control Schematics Figure 11: Control Schematic New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 57: List Of Illustrations

    Belt Replacement & Adjustment Motor Assembly Replacement Cooling Coil Installation Cooling Coil Installation Control Board Replacement Gassing Manifold Kit Installation Control Schematic I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 58: Index

    Location of, 4 Interpreting the, 21 Cooling Coil Kit, 27, 40 Cooling Coil Option, 7 Installing the, 27 Copyright Notice, vii Indicated Temperature, 20 New Brunswick Scientific User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 59 Retrofit Options Available, 7 Routine Maintenance, 23 WARNING RPM Indicator Light, 6, 17 Symbol for, vii Running Time Warranty, ix Displaying the, 21 Weight, 38 I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 60 I-2400 • M1283-0050 User’s Guide Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 61 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

Table of Contents