  • Page 1 Humidistat-Thermostat Owner’s Manual PNEG-236 Date: 04-11-07 PNEG-236...
  • Page 2 Pneg-236 Humidistat-Thermostat...
  • Page 3: Table Of Contents

    Lo-Temp Humidistat-Thermostat Parts ................15 Hi-Lo Humidistat-Thermostat Parts ................... 16 Chapter 8 Thermostat Wiring ......................17 Humidistat-Thermostat Wiring ................... 17 Thermostat Wiring ......................18 Humidistat Wiring ......................19 Humidistat-Thermostat ...................... 20 Chapter 9 Mounting Template ......................21 Chapter 10 Warranty ......................... 23 PNEG-236 Humidistat-Thermostat...
  • Page 4: Chapter 1 Safety First

    Thank you for choosing a GSI product. It is designed to give excellent performance and service for many years. The principal concern of The GSI Group, Inc. (“GSI”) is your safety and the safety of others associated with grain handling equipment. This manual is written to help you understand safe operating procedures, and some of the problems that may be encountered by the operator or other personnel.
  • Page 5: Chapter 2 Safety Decals

    The GSI Group, Inc. recommends contacting your local power company, and having a representative survey your installation so the wiring is compatible with their system, and adequate power is supplied to your unit. Safety decals should be read and understood by all people in the grain handling area. The bottom right decal should be present on the inside bin door cover of the two ring door, 24"...
  • Page 6 2. Use a safety harness and safety line. 3. Satation another person of the bin. 4. Avoid the center of the bin. 5. Wear proper breathing equipment or respirator. Failure to heed these warnings will result in serious injury or death. DC-GBC-1A PNEG-236 Humidistat-Thermostat...
  • Page 7 Figure 3A PNEG-236 Humidistat-Thermostat...
  • Page 8: Chapter 3 General Installation

    4. Carefully insert sensing probes through bin wall and secure housing to wall using self- drilling screws provided. Be careful not to overtighten screws. Damage to housing could result. 5. Make wiring connections to heater as shown in heater owners manual. PNEG-236 Humidistat-Thermostat...
  • Page 9: Chapter 4 Installation Of Top Dry Hi-Lo Thermostat

    Installation of Hi-Lo Thermostat The Hi-Lo Thermostat is designed for use with the GSI Top Dry Crop Dryer units. It comes with one thermostat which is adjustable and cycles the heater from high to low flame. The Hi-Lo Thermostat also comes with a thermometer for monitoring the plenum temperature.
  • Page 10: Chapter 5 Operation

    3. Set the humidistat to the desired relative humidity level you want to maintain under your drying floor. The heater will cycle on above this relative humidity, and OFF when this level is reached. 4. Use the equilibrium moisture chart be low as a guide for setting the humidistat. PNEG-236 Humidistat-Thermostat...
  • Page 11 13.9 14.8 15.8 17.4 20.0 22.8 Boxed area indicates safe moisture for normal winter storage of shelled corn at 15%. Grain to be stored through the summer or long term, needs to be 1 to 3 points dryer. PNEG-236 Humidistat-Thermostat...
  • Page 12: Chapter 6 Operation & Service

    OFF. (Top Dry units will shut down completely). Humidistat - Thermostat Service GSI Thermostats are designed and built to withstand the harsh conditions usually found in drying bins. A yearly preventative maintenance inspection may extend the life of your heating controls many years.
  • Page 13 5. Replace the back panel and caulk the corners to help seal the unit. 6. Reinstall the unit on the bin wall. The Airstream Humidistat-Thermostat is mounted on the lower right side of the grain bin's transition. This allows for easy service and operation. PNEG-236 Humidistat-Thermostat...
  • Page 14: Chapter 7 Thermostat Parts

    HF-1433 Humidistat HF-1434 Static Pressure Gauge HH-1435 220 Degree Thermometer HH-1436 Screen Plug HH-1970 Plastic Knob HH-2089 Large Red Plastic Plug HH-1442 Toggle Switch HF-7108 Thermostat Cover HH-7032 Rubber Grommet HH-7029 Heat Shrink Tube 1/2" HF-7110 Humidistat Cover PNEG-236 Humidistat-Thermostat...
  • Page 15: Lo-Temp Humidistat-Thermostat Parts

    4.00" Plastic Housing HF-3974 Lo-Temp Thermostat HF-1433 Humidistat HF-1434 Static Pressure Gauge HH-3973 140 Degree Thermometer HH-1436 Screen Plug HH-1970 Plastic Knob HH-2089 Large Red Plastic Plug HH-1442 Toggle Switch HF-7108 Thermostat Cover HH-7032 Rubber Grommet HF-7110 Humidistat Cover PNEG-236 Humidistat-Thermostat...
  • Page 16: Hi-Lo Humidistat-Thermostat Parts

    4.00" Plastic Housing HF-7028 Lo-Temp Thermostat HF-1434 Static Pressure Gauge HF-1435 220 Degree Thermometer HH-1436 Screen Plug HH-1970 Plastic Knob HH-2089 Large Red Plastic Plug HH-7029 Heat Shrink Tube 1/2" HH-7108 Thermostat Cover HF-7032 Rubber Grommet HF-7110 Humidistat Cover PNEG-236 Humidistat-Thermostat...
  • Page 17: Chapter 8 Thermostat Wiring

    Humidistat-Thermostat Wiring THERMOSTAT BYPASS SWITCH Black Purple HUMIDISTAT Wire Nut Purple Black Connect to Heater as shown in Heater Manual Figure 8A PNEG-236 Humidistat-Thermostat...
  • Page 18: Thermostat Wiring

    8. THERMOSTAT WIRING Thermostat Wiring Figure 8B PNEG-236 Humidistat-Thermostat...
  • Page 19: Humidistat Wiring

    8. THERMOSTAT WIRING Humidistat Wiring Figure 8C PNEG-236 Humidistat-Thermostat...
  • Page 20: Humidistat-Thermostat

    8. THERMOSTAT WIRING Humidistat-Thermostat Figure 8D PNEG-236 Humidistat-Thermostat...
  • Page 21: Chapter 9 Mounting Template

    Figure 9A PNEG-236 Humidistat-Thermostat...
  • Page 22 NOTES Pneg-236 Humidistat - Thermostat...
  • Page 23: Chapter 10 Warranty

    WARRANTY OF ANY KIND, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE IN CONNECTION WITH (I) PRODUCT MANUFACTURED OR SOLD BY GSI OR (I) ANY ADVICE, INSTRUCTION, RECOMMENDATION OR SUGGESTION PROVIDED BY AN...
  • Page 24 Should Be Carefully Followed In All Cases. Authorities Having Jurisdiction Should Be Consulted Before Installations occurs. GSI Group, Inc. 1004 E. Illinois St. Assumption, IL 62510-0020 Phone: 1-217-226-4421 Fax: 1-217-226-4420 Internet: http://www.grainsystems.com Copyright © 2007 by the GSI Group Printed in the USA...