Sonnen SonnenProtect 1300-AU-IN-ATS Installation Instructions Manual

Advertisement

Quick Links

Installation instructions

for authorized electricians
sonnenProtect 1300-AU-IN-ATS
AUD0420
130002
support@sonnen.com.au www.sonnen.com.au
KD-
· Art.-Nr.
· Version X01

Advertisement

Table of Contents
loading

Summary of Contents for Sonnen SonnenProtect 1300-AU-IN-ATS

  • Page 1: Installation Instructions

    Installation instructions for authorized electricians sonnenProtect 1300-AU-IN-ATS AUD0420 130002 support@sonnen.com.au www.sonnen.com.au · Art.-Nr. · Version X01...
  • Page 2: Table Of Contents

    5.2.1 Requirements for the installation location of the sub-board ................10 5.2.2 Observe minimum distances ..........................10 6 Accessory installation ............................... 11 6.1 Installing the sonnenProtect 1300-AU-IN-ATS accessory ................... 11 6.3 Connecting the cable and strands .......................... 12 6.3.1 Removing the dummy plug............................ 12 6.3.2 Installing the cable gland ............................
  • Page 3 7.1.2 Switching on the grid voltage ..........................16 7.2 Testing function ................................17 7 Troubleshooting ................................18 8 Decommissioning ................................19 9.1.2 Disposal ..................................19...
  • Page 4: Information About This Document

    This document is intended for accredited sonnen installers & qualified electricians. The actions described here must only be carried out by accredited sonnen installers & qualified electricians. The installation and commissioning of the sonnenBatterie and sonnenProtect 1300-AU-IN-ATS must be carried out by an accredited sonnen installer.
  • Page 5: Safety

    2 Safety 2.1 Intended use The sonnenProtect 1300-AU-IN-ATS is an emergency power unit accessory designed to supplement the sonnenBatterie eco 9.43. The sonnenProtect provides power to be supplied to a connected sub-board and load circuits if a grid outage occurs.
  • Page 6: Installation Requirements Of The Sonnenprotect

    The interfaces of the sonnenProtect and the storage system must be wired in accordance with the product documentation / installation manual. All repairs on the sonnenProtect must be performed by authorised sonnen service technicians only. 2.5 Operational voltage of the sonnenProtect The sonnenProtect is connected to live electrical parts, which poses a risk of electrical shock.
  • Page 7: Product Description

    Safety Protection Standard IEC 61009-1; AS/NZ 61009-1 Protective functions Overcurrent & Earth Leakage Degree of protection IP 30 (as per sonnen eco 9.43 main unit) Ambient conditions Ambient temperature range 40 °C Storage temperature range 50 °C Transport temperature rang 50 °C...
  • Page 8: System Components

    3.2 System components Designation Function sonnenProtect1300-AU-IN-ATS Contactor module Inverter connector cable Grid & Backup supply connection Output cable Connection cable to backup sub-board 30mA RCBO 10A RCD for installer to connect to AC output 25A MCB Main isolator for sonnenBatterie AC grid supply 6A MCB Main isolator for backup circuits after the RCBO 3.3 Function...
  • Page 9: Transport And Storage

    5 Mounting 5.1 Scope of Delivery ► Check the following scope of delivery to ensure it is complete. Designation Pre-assembled sonnenProtect 1300-AU-IN-ATS accessory M20 cable gland M20 cable gland nut 30mA RCBO 10A RCD for installer to connect to AC output...
  • Page 10: Selecting The Installation Location

    5.2 Selecting the installation location 5.2.1 Requirements for the installation l ocation of the sub-board ► Observe the required ambient conditions (see 3.1). The output cable of the sonnenProtect accessory is approximately 150cm allowing for the following optimal sub-board location to allow the unit to be easily reached. 5.2.2 Observe minimum distances ►...
  • Page 11: Accessory Installation

    ► Wait five minutes so the capacitors can discharge. ► Check that the device is disconnected from the power supply. ► Only authorized electricians & accredited sonnen installers are permitted to carry out electrical work. 6.1 Installing the sonnenProtect 1300-AU-IN-ATS accessory ►...
  • Page 12: Connecting The Cable And Strands

    6.3 Connecting the cable and strands 6.3.1 Removin g the dummy plug Tools: • Screwdriver with a thin blade (0.4 mm) Remove the dummy plug shown. A screwdriver with a thin blade can be used for this purpose. 6.3.2 Installing the cable gland Tools: •...
  • Page 13: Wiring The Output Cable

    6.3.3 Wiring the output cable ► Wire the connection cable of the sonnenProtect through the cable gland to the inside of the storage system. ► Only pass the output cable through the gland top the external of the main unit if the backup circuit is to be wired into a sub-board.
  • Page 14: Connecting The Cables And Strands

    6.3.4 Connecting the cables and strands ► Connect the Active & Neutral cable from the sonnenProtect to the X2 Inverter AC backup power supply terminal. ► Disconnect both Active & Neutral supply cable from the T2 AC Power Supply by inserting a small flat screwdriver into the slots adjacent to each terminal input.
  • Page 15: Completing Installation

    (1300W) need to be considered. To enable this situation, included within the sonnenProtect 1300-AU-IN-ATS kit set is a 25A main MCB which should be used as the sonnenBatterie MCB (Main AC isolator). In addition to the higher rating of the protective device the supply cable itself depending upon route length and location may also need to be replaced with a larger CSA cable.
  • Page 16: Commissioning

    If the storage system cannot be switched on: ► Do not attempt switching on the storage system more than three times. ► Contact sonnen service! Further attempts can damage the battery modules. Fuse switch F1 establishes the connection between the battery and the inverter.
  • Page 17: Testing Function

    6. Check whether the sonnenProtect is behaving as described for emergency operation in section 3.3. 7. Ensure that the illuminated eclipse of the sonnen main unit has turned green whilst the unit is in backup mode. If the sonnenProtect is behaving as described in section 3.3, the function test is successful. The sonnenProtect can be operated.
  • Page 18: Troubleshooting

    7 Troubleshooting Disturbance Possible reason Correction The output of the sonnenProtect There is an insulation fault. ► Correct the insulation fault. is not supplying any power. The RCD has switched off. The output of the sonnenProtect There is a grid outage. The battery ►...
  • Page 19: Decommissioning

    8 Decommissioning Voltage in the event of a grid outage Danger to life due to electrocution! The output of the sonnenProtect remains live even in the event of a grid outage or when the main fuses are switched off. ► The sonnenProtect must be switched off separately. 8.1 Switching off the out put ►...
  • Page 20 www.sonnensupport.com.au...

Table of Contents