Download Print this page

HEINRICH VAC/C Product Manual

Digital network public address & voice alarm system

Advertisement

Quick Links

Digital Network
Public Address & Voice Alarm System
HEINRICH
VAC/C
DIGITAL NETWORK PUBLIC ADDRESS
& VOICE ALARM SYSTEM
Thanks for using HEINRICH Digital Network Public Address & Voice Alarm System.
For better operation, please read this manual carefully before operating the system.
HEINRICH LIMITED,
71-75 SHELTON STREET COVENT GARDEN LONDON
T:
+442032860291
W:
www.heinrichlimited.com
E:
info@heinrichlimited.com

Advertisement

loading
Need help?

Need help?

Do you have a question about the VAC/C and is the answer not in the manual?

Questions and answers

Summary of Contents for HEINRICH VAC/C

  • Page 1 Public Address & Voice Alarm System VAC/C DIGITAL NETWORK PUBLIC ADDRESS & VOICE ALARM SYSTEM Thanks for using HEINRICH Digital Network Public Address & Voice Alarm System. For better operation, please read this manual carefully before operating the system. HEINRICH HEINRICH LIMITED,...
  • Page 2 Digital Network Public Address & Voice Alarm System 1. Dear Readers Thank you for using HEINRICH re voice broadcasting system, in order to facilitate your understanding and the manual’s description, suggestion are as follows: The mentioned "Voice information" in the manual includes Built-in EVAC, ALERT voice.
  • Page 3 11) Because the appearance and functions of this system will continue to upgrade, but are backward compatible, any discrepancy in kind, please in kind prevail. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 4 3. Products Introduction 3.1 Voice alarm system controller - VAC/C EVA system is a combination of leading electronic intelligent voice warning, alarm and public address system, can not only alert and alarm (alarm mode and alarm voice can be done by programming), but also achieve refuge guidance, It is an intelligent PA system in the absence of re.
  • Page 5 Red rapid ashing - the system is currently operating in a reset mode, prohibiting all manual operation. • O - The system is currently operating in normal mode. • Note: 1. When the light is ashing, press to exit the emergency mode. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 6 When system is under non-primary interface system, press this button to enter system log interface. Note: The order of execution - PTT broadcast - Select Partition - System fault - return to the main interface. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 7 16. Host chassis ground (Note: Please ensure reliable ground at this point). 17&18. AC Main power input socket (with fuse and power switch, check the voltage range before energizing). HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 8: Specification

    Digital Network Public Address & Voice Alarm System SPECIFICATION: Model VAC/C AC power supply Voltage ~220V 50Hz The maximum current Less than 0.2A Fuse specifica�ons 250V/1A, slow type Power consump�on DC power supply Voltage 24V DC, ± 20% Maximum current 1.5 A...
  • Page 9 484*132*449 mm (19 inch width, 4U) Net Weight About 8.0 kg Installa�on Desktop or 19 inch rack Color Black Environmental requirements Opera�ng temperature +5℃~+ 40℃ Storage temperature -20℃ ~+ 70℃ Rela�ve temperature <95% HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 10 • Position System Charger connected decide its status attached to the corresponding device, such as a host VAC/C, backup power have con gured, want to know the current con guration of the charger working status, we need to enter the corresponding DC power menu to view;...
  • Page 11 "means direct access to the system" logo screen " which is standby interface. Enter EVAC host,then enter the main menu to view status: Click on logo interface EVAC host HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 12 • Battery Operating Temp: +00 Celsius degree (system detects battery’s operating temp.) Check other charger status by pressing up and down icon when there is more than one charger. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 13 Tracks: 1, 2 (prompt tone list: the former is the tone before speech, the latter is the tone after speech) Con gure in software. • Handheld MIC (Gooseneck MIC): Normal/Fault. • Interface 1 (corresponding to remote microphone interface on rear panel) HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 14 Line Input Volume… Enter submenu (Line Input Volume) by pressing this icon to adjust line input volume. Check other line input status of other VAC/C by pressing up and down icon when there is more than one VAC/C. Note: system default setting con gures one VAC/C, the following is the same;...
  • Page 15 View working status of 8 Channel Changeover (8 main/1 spare ampli er switcher): In Main Menu, press ampli er controller to view submenu: Main Menu Ampli er Controller Menu Status instruction for ampli er controller menu (from top to bottom): HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 16 Battery Operating Temp.: +00 Celsius degree (system detects battery operating temp.) Check other charger status by • pressing up and down icon when there is more than one charger. Ampli er Changeover Charger Menu Page on Host Touch Screen HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 17 03 output; if several main am- pli ers break down at the same time, system will switch in following order: CH1>CH2>CH3>CH4>CH5>CH6>CH7>CH8. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 18 PC software). Check other ampli er changeover status by pressing up and down • icon when there are more than one ampli er changeovers. Ampli er Changeover Online Interface on Rear Panel Connecting diagram: HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 19 Battery Operating Temp.: +00 Celsius degree (system detects accumulator operating temp.) Check other charger • status by pressing up and down icon when there is more than one charger. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 20 Audio Priority Menu. (Press up and down icon to view priority level of other zone ampli er). Zone Ampli er 01-Audio Priority (Priority level can be con gured in PC software). HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 21 ”menu into “system time setup menu” ( rst click on the number, then, press” ” Button adjust system time, it can be calibrated synchronously in the PC software). HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 22 In the "System Settings Main Menu", click the " " submenu, enter into"system language selection menu, " check the box, you can select the current language interface switching, see "System language selection menu" HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 23 PC software. Input Volume: 31, indicates the volume level of the current remote telephone, you can click on the " " • key to adjust. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 24 In the interface of the main menu, click on “ ”to enter the partition control menu, you can view partition state, control partition, monitor, control volume and play background, etc. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 25 , the system will automatically play background music, at the same time, the partition of the status bar wil display the inform tion channel. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 26 Multiple hosts background music playing: if there are two sub control hosts, you can select host 01 or host 02 BGM music playback, playback steps is same as the above operation. HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 27 1. VAC/C emergency broadcasts steps 1.1 Press the EMERGENCY work switch on the host VAC/C; after pressing, it enters into emergency mode (slow blinking red); at the same time, the host of "Logo standby interface" will activate emergency mode, "...
  • Page 28 3. Contacts trigger an automatic emergency broadcasts steps: When input a trigger on the INPUTS MODE from machine VAC/C / 8 Channel Changeover / 8 Zone Voice Alarm Ampli er, the MODE OUTPUTS interface will be triggered emergency when receiving the corresponding trigger signal, and execute the emergency broadcast signal to the related zones.
  • Page 29 2. Reset operation on the host interface after online connection When the re alarm reset trigger is contact, after the host VAC/C received short trigger reset signal re, the system will go into the reset state, EMERGENCY push-button switch will turn from slow red ashing to be fast red ashing, after ashing red stop, reset is nished.
  • Page 30 "System Global Parameters Con guration ", as shown below, you can change the priority data from "Audio priority con guration" according to actual needs level digital, you can adjust priority con guration on VAC/C. Description: The lower the priority number, the higher priority (0- is the highest priority).
  • Page 31 HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com...
  • Page 32 12. Speaker (short circuit or open circuit) 13. The speaker (ground fault) Through Setting on host VAC/C and software EVAC System PC, users can enable or disable the above detection on monitoring events. The operation steps of starting and forbidding module detection in VAC/C and EVAC System system can perfor real-time detection and monitor to all the online equipments it connects.
  • Page 33 Suppose that there is malfunction in the connection between Microphone and VAC/C. When the malfunction is detected, the system will have the following situations: 1. The buzzer in VAC/C will ring on, the system indicator will turn to yellow and ash, and the LCD screen will show the malfunction.
  • Page 34: Block Diagram

    Digital Network Public Address & Voice Alarm System BLOCK DIAGRAM HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 35 Digital Network Public Address & Voice Alarm System With backup function Signal partition, power partition (can extend to 255 zones, power partition can expand to 56 zones ) HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 36 Digital Network Public Address & Voice Alarm System Signal partition (which can extend to 255 signal zones) HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 37 Digital Network Public Address & Voice Alarm System Signal partition , power partition (can extend to 255 zones, power partition can expand to 56 zones ) HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...
  • Page 38 Digital Network Public Address & Voice Alarm System Power partition (power partition can expand to 56 zones) HEINRICH HEINRICH LIMITED, 71-75 SHELTON STREET COVENT GARDEN LONDON +442032860291 www.heinrichlimited.com info@heinrichlimited.com...