Thank you for purchasing this Softener. We are sure that it will provide you with trouble free service for many years to come. Please use the following pages to assist you in the installation and set up of your new Softener. Planning Your Installation.
Page 3
Connecting the Softener. Once you have completed the installation of the valves set the valves as follows: Softener Inlet and Outlet valve CLOSED Bypass valve OPEN You can now safely return the stop cock to the open position. Using the hoses provided (if installation kit ordered) connect the straight end of the hose having first inserted the washer provided to the softener inlet and outlet valves.
Page 4
Overflow Connection. The overflow connection is the white ½” hose spigot on the rear or side of the cabinet. A clip is not required for this connection. The overflow must be run downhill through an outside wall without kinks or restrictions. It is recommended the overflow hose be visible when it exits the outside wall.
Page 5
Quick Set Up Guide The main user guide should only be used for reference purposes, please use this guide for initial programming. Your Softener should already have been set up with the basic settings in the factory! The only settings you should need to enter are the time of day, day of week and the water hardness 1.
Page 6
Press the set button to accept this setting and again to the next setting. The following will then be displayed. Set Days to Regenerate (760 Metered units only). This setting is a default override setting to allow for optimum performance of the resin it should be regenerated at least every 7 –...
Page 7
Commissioning the Softener Close the stop cock again and then open the inlet and outlet valves to the softener. Press and hold the regenerate button (4) you should hear the cam rotate and the following display will appear, when the cycle indicator shows C1 slowly open the stop cock about a quarter of the way, this will purge the air from the system.
Page 8
Identify the settings relevant to your softener from the chart below by looking at the vessel size and controller type. Typical settings for 740 & 760 softeners, Vessel Size 613 1012 817 822 919 735 1023 835 935 1035 Media Volume to program (litres) 10 15 15 20...