Dual Door Gate Control Shift Between Main and Subordinated Readers Check all Records (including deleted ones), 9999available in maximum Date and time setting Valid date control DI (NC / NO) Setting K1(Latch / Momentary) Setting HEART ENTERPRISE CO., LTD. 12.10.2003...
Page 5
Arm protection Dual Door Gate Control Shift Between Main and Subordinated Readers Check all Records (including deleted ones), 9999 records available in maximum Date and time setting DI (NC / NO) Setting K1(Latch / Momentary) Setting HEART ENTERPRISE CO., LTD. 12.10.2003...
HB0312 Green T-/TXD RS485 T- or RS232 TXD Blue T+/RXD RS485 T+ or RS232 RXD “WIEGAND data1〞on subordinated reader Purple DATA1 “WIEGAND data0〞on subordinated reader Gray DATA0 White LED Signal Light on subordinated reader HEART ENTERPRISE CO., LTD. 12.10.2003...
10P WIRE 10P WIRE Blue Blue Blue Gree Gree Gree HA5035 #33 TO #64 SETS RS485 DATA BUS 1 RS485 DATA BUS 2 10P WIRE 10P WIRE HA5035 to RS485 structure Blue Blue Blac Gree Gree HEART ENTERPRISE CO., LTD. 12.10.2003...
Associated with RS485 communication interface, HA5035 may be connected to 255 machines in maximum, and used with insulation twisted cable and controlled within 1000 meters for distance between each reader and PC Default Setting of HA5035 communication signal is RS485 HEART ENTERPRISE CO., LTD. 12.10.2003...
READY FOR CARD SET UP Startup screen 2003/09/01 12:00 press ’*’ to press ’#’ for 3 0.CHECK VERSION. seconds 1.SET UP escape the screen PASSWORD: press’1’ button Enter the PASSWORD:**** Enter parameter password :1111 setting mode HEART ENTERPRISE CO., LTD. 12.10.2003...
8 digits as the time correct card number press ’# ’ to exit or READY FOR CARD End up with operation and automatically exit 2003/09/01 12:01 back to the start up screen after 25 seconds HEART ENTERPRISE CO., LTD. 12.10.2003...
Back to normal operation, and Strike works to allow ordinary access. If unable to disable alarm after above steps, please turn off power and then restart. (3)Door open too long alarm: Door open too long will drive alarm, which may be set on HA5035 reader for time HEART ENTERPRISE CO., LTD. 12.10.2003...
The card which is sensed on the reader to open door, but not used on the subordinated reader for exit, may not be applied for door open on the reader again, but without any restriction for exit on the subordinated reader HEART ENTERPRISE CO., LTD. 12.10.2003...
Arm protection may be shifted between Enable/Disable on HA5035 reader (preset as Disable) On latch mode, the relay may not work even the arm protection is set as “Enable” HEART ENTERPRISE CO., LTD. 12.10.2003...
Page 18
X X X X # * [card number] # security password 4、Press card number and personal password for door opening X X X X # * [card number] # X X X X # personal password security password HEART ENTERPRISE CO., LTD. 12.10.2003...
The reader is prepared with the spare password, as 23400204 unchangeable, which is used to replace the Master Password to edit parameters on the reader and has to work associated with an enrolled proximity card. HEART ENTERPRISE CO., LTD. 12.10.2003...
1. HP1506 power pack:The reader can control 5 relays and catch statuses of 3 inputs on Power Pack of HP1506 through 2 signal cables , as well as 1 AC power failure (ACP) signal cable (ACP) to show power supply status on reader. Functions for 5 relays HEART ENTERPRISE CO., LTD. 12.10.2003...
Default : O,7,1 Baud rate:9600 or 19200 selectable. Default 9600. Program upgrade can be done by PC Down Load Save data of 12,000 card holders and 14,000 data transaction, with alarm when emory use up to over 90% HEART ENTERPRISE CO., LTD. 12.10.2003...
Page 23
There will be 25-second time out during password and card number input, and parameter setting. Press [#] for continuous 3 seconds to enter the parameter check/edit menu. Allow to check program type, program vision, card enrollment number, and record number. HEART ENTERPRISE CO., LTD. 12.10.2003...
The message shows usually for door opening by press card number. Re-confirm and re-enter the card number (7) 【E08】SYSTEM ARMED Arm protection The message shows the system under arm protection. Any card reading invalid without system disarm. (8) 【E09】INVALID CARD invalid card HEART ENTERPRISE CO., LTD. 12.10.2003...
20 seconds Delay open alarm (Disable) Patrol relay drive time 5 seconds Strike relay drive time 5 seconds Alarm relay drive time 10 seconds Anti-duress relay drive time 5 seconds Door fan open/ close inspection HEART ENTERPRISE CO., LTD. 12.10.2003...